HomeMy WebLinkAbout06012010 Planning & Zoning Work Session Laydown WIND ENERGY CONVERSION SYSTEM
ZONING - SITE PLAN REVIEW
(SCC 15.10.245)
Property Owner: Leirer Enterprises LLC, AVTEC Lease Builder: STG Inc.
Property Address: 1904 Alameda Street Tax Parcel No. 14525040
Legal Description: Leirer Industrial Sub., Lot 2, Block 1
Building Permit No: 2010-43
Proposed Use: Wind Energy Conversion System ! ;,
Existing Structures: None
Zoning District: Industrial Use Allowed: NOS
`4y
Review Requirements: Code Standards Protect Proposal
Free Standing WECS Height(FT)per 15.10.245 155 max all districts, Tower Height=99 ft.
excluding 1,RM&
INS,which is 3001 Max Blade Height= 132 ft.
Roof Mounted WECS Height(FT)per 15.10.245 20 in all zoning N/A
districts on buildings
34 feet or less
Minimum Blade Ground Clearance(FT)per 15,10.245 15 Blade ground clearance=66 ft.
WECS Setback From All Property Lines(including guy wires 1.1 times height of Proposed Setback/Required
and anchors)per 15.10.245 WECS system North: 70 ft.(Approx)/ 145.2 ft.
South: 125.26 ft./ 145.2 ft. ✓
East: 112.01 ft.1145.2 ft.
West: 146.30 ft./ 145.2 ft.
Noise Setback of 50dB or less as measured at property line. <50dB at lot line Specs.=55 dB @ 278 ft.
Formula:Ss=I 0^(Lw+Lu+Ls+-.5-5 0)/20)per 15.10.245 Formula= >50 dB at lot line
WECS Located So Principal Structure is Between WECS and WECS at rear or side of 1pI< l Vd Aml
Front or Side Property Line,per 15.10.245.(e.�(f Cc.� principal structure
All Portions of the WECS shall be a Non-Reflective,Non- Non-Reflective Proposal: All White
Obtrusive Color,per 15.10.245
All Power&Telemetry Lines from WECS shall be placed None II ;�-see-diagram
underground,per 15.10.245
Special Setback when abutting residential district and not same requirements as No Change
separated by a right of way 15.10.230 district abutting
Max%Lot Coverage 15,10.140,Lot,buildable or useable area By District-y7 /��}°/� Tower Pad= 466.56 sq.ft.OK
Signs SCC I2.01 I t ` (e- 9 Not Allowed No Signage I Logo Plan Provided
Flood zone& 17'abv MLLW'12.01.015&KPB 21.06 Zone C
Building on Interior Lot Lines(commercial)' 12.01.030 None
Utility Easements/Encroachments(look on deeds/plats) None Identified
WECS Setback From Nearest Power/Utility Lines > 145.2 ft./Underground Lines
Comments: 7,
Site Plan: Approved
Community Development Date
WIND ENERGY CONVERSION SYSTEM
ZONING - SITE PLAN REVIEW
(SCC 15.10.245)
Property Owner: Builder:
Property Address: Tax Parcel No.
Legal Description:
Building Permit No:
Proposed Use:
Existing Structures:
° Zoning District: Use Allowed: Yes
IIJ
Review Requirements: Code Standards Project Proposal
Free Standing WECS Height(FT)per 15.10.245 155 max all districts,
excluding 1,RM& 70
INS,which is 300
\ Roof Mounted WECS Height(FT)per 15.10.245 20 in all zoning N/A
districts on buildings
34 feet or less
Minimum Blade Ground Clearance(FT)per 15.10.245 15 55
WECS Setback From All Pr ope y . y vGi 1.1 times egg Ft of DWS 70 A.(70 x 1 1 :_7.7 ft.)_ .
_ Et✓ osed 97 ft.-setback-OK—
and anchors) r 15.10.245
Noise Setback of 50dB or less as erty line. <50dB at lot line Formula=26 dB
Formula: Ss=10^(Lw+Lu+Ls+-.5-50) Or per4&-".245Tf
ECS Located So Principal Structure is Between WECS and WECS at rear or side of OK
Front or Side Property Line,per 15.10.245 principal structure
All Portions of the WECS shall be a Non-Reflective,Non- Non-Reflective Proposal. White tower,white
Obtrusive Color,per 15.10.245 turbine blades
All Power&Telemetry Lines from WECS shall be placed None OK,see diagram
underground, per 15.10.245
Special Setback when abutting residential district and not same requirements as No Change
separated by a right of way 15.10.230 district abutting
Max%Lot Coverage 15.10.140, Lot, buildable or useable area By District //�� 20%RR District,OK
Signs SCC 12.01 A[,,{' Mtw t"tn. NIA
Flood zone& 17'abv MLLW'12.01.015 &KP1321.06 Zone C
Building on Interior Lot Lines(commercial)' 12.01.030 None
Utility Easements/Encroachments(look on deeds/plats) None Identified
Comments:
ii
Pla ApprovRl
Community Development Date