HomeMy WebLinkAbout03202024 PACAB Work Session UplandsPREFACE This document was prepared for the City of Seward as a guideline for future development of the South Harbor Uplands. City of Seward P.O. Box 167 Seward, AK 99664 City Council Clark Corbridge Mayor Willard Dunham Vice Mayor Jean Bardarson Council Member Betsy Kellar Council Member Bob Valdatta Council Member Tom Smith Council Member Marianna Keil Council Member Planning and Zoning Commission Sandie Roach’ Chair Margaret Anderson Vice Chair Steven Heinrich Commission Member Sue McClure Commission Member Tena Morgan Commission Member Port and Commerce Advisory Board Ron Long Chair Theresa Butts Vice Chair Deborah Altermatt Board Member Daniel Oliver Board Member Darryl Schaefermeyer Board Member Paul Tougas Board Member City Administration Phillip Oates City Manager Kari Anderson Harbor Master Christy Terry Community Development Director Karin Sturdy Parks and Recreation Director Donna Glenz Associate Planner Anne Bailey Executive Liaison Citizens of Seward The involvement of many Seward residents in preparation of the South Harbor Uplands Plan is gratefully acknowledged. 240320 PACAB Work Session Laydown-Uplands South Harbor Uplands Plan Introduction Under the June 2003 Project Cooperation Agreement between the Department of Army (the “Corps”) and the City of Seward (the “City”) for Construction of the Harbor Improvements (the “Agreement”), dredged and excavated material was deposited behind the newly extended breakwater creating approximately 3.5 acres of filled land described by the Corps as “BOD Disposal Area 1.” On February 12, 2007, the City authorized the approval of the Department of Army Memorandum for record and accepting Disposal Area 1. The City of Seward has received inquires about leasing land and using the South Harbor Uplands for parking. The Port and Commerce Advisory Board (per the City Manager’s request) has discussed possible development ideas for the area and have suggested that a South Harbor Uplands Plan be created to maximize the use of the area and benefit the Seward community. The purpose of the South Harbor Uplands Plan is to achieve long-term objectives for the area and provide guidance on how the land should be developed for economic and recreational use. The South Harbor Upland Plan contains advisory elements, which include strategies for improving public services and facilities, promoting economic development and maintaining and enhancing the quality of life. The plan elements include: Zoning, Land Use, Parking and Transportation Facilities, Public Facilities and Services and Community Appearance. These planning issues need to be considered to maintain a planned development of the area and retain Seward’s unique histories, small- town character, while pursuing modern economic development and maintain the natural beauty for the community to enjoy. This plan has been prepared with the assistance of the Port and Commerce Advisory Board, the Planning and Zoning Commission, community members, and City of Seward staff through a series of public meetings. 240320 PACAB Work Session Laydown-Uplands South Harbor Uplands Area Collection of Ideas The Plan for the South Harbor Uplands Fill Area is to zone the area Harbor Commercial District and Park District and to use the area for retail, a Mariners Memorial, a handicap accessible fishing pier, scientific research and camping. The plan will also address parking expansion, boardwalk/sidewalk extension, road access, drainage, utilities, public safety and aesthetics. ZONING Goal: Zone the area Harbor Commercial District and Park District to accommodate economic development and parks and recreation. (What is the City’s stance?) Harbor Commercial District- The northern 1/3 portion 1 of the South Harbor Upland area would be designated Harbor Commercial District to accommodate retail and other forms of economic development. Park District- The southern 2/3 portion1 of the South Harbor Upland area would be designated Park District. This area will accommodate the Mariner’s Memorial and the handicap accessible fishing pier and would maintain the view of Resurrection Bay. Designating the area Harbor Commercial and Park District is consistent with the zoning map but does not adhere to the land use map. The land use map designates the area as Park district. The Port and Commerce Advisory Board recommended via PACAB Resolution 2008-03 to designate the area Harbor Commercial. LAND USE Goal: The area would be used for economic development, parks and recreation, parking and scientific research. Economic Development o Retail areas will be available on the Harbor Commercial portion for lease via a designated process. o Plat areas to designated parcel size. o Create a list of criteria for building on the fill area. 1 The portions designated Park District and Harbor Commercial District will be determined by an engineer. 240320 PACAB Work Session Laydown-Uplands o Lease the parcels at fair market value. o Leases of the parcels should be carefully drafted with “subject to” language alerting grantee of dominant estates and Army Corps of Engineers access rights, etc. o All development must comply with the Seward City Code. Parks District Mariners Memorial o The Planning and Zoning Commission, the Historic Preservation Commission, the Port and Commerce Advisory Board and City Council supported the concept of the Mariners Memorial for the Small Boat Harbor.2 o In March 2004, a donation of $1,000.00 (one thousand dollars) by the Kenai Fjords Yacht Club started a Mariners Memorial Fund through the 2003 Seward Centennial non-profit account and additional donations and grants to fund the design, construction and maintenance of the Memorial will continue to be sought by local organizations and individuals. o A 100 foot by 100 foot piece of land located on a southeast portion of the South Harbor Uplands Area has been designated for the Mariner’s Memorial. o A conceptual design of the memorial has been completed. A small scale model will be created and then the final project will be constructed. o The Harbor Department will help maintain the facility. Handicap Accessible Fishing Pier o Construct a handicap accessible fishing pier at the south side of the South Harbor Upland Area. o Grant money 3 or capital project funds will be needed to accomplish this project. Restroom Facilities 2 City Council Resolution 2006-49; Planning and Zoning Resolution 2006-10; Historic Preservation Resolution 2006-01 and Port and Commerce Advisory Board Resolution 2006-07 3 Project may be funded through “Dingell Johnson” money collected from sport-fishing licenses. 240320 PACAB Work Session Laydown-Uplands o The restroom facilities were completed September 2007.4 o The restroom facility has electric, water and sewage capabilities. o The restroom facility is maintained by the Harbor Department. Camping Facilities 5 o Create high end Recreation Vehicle (RV) camping facilities on the southern strip of the South Harbor Uplands. o Water, sewer, electric and cable capabilities available for campers, in compliance with other existing camping regulations, such as 14-day stay maximum limit. o Set a rate for the high end camping sites.6 Scientific Research Harbornet System o The University of Alaska Anchorage (UAA) and the Alaska Ocean Observing System (AOOS) would set up a “Harbornet system” on the South Harbor Uplands area to monitor wind, temperature, precipitation, wave and tidal activity. o The location of the tower/sensors 7 will be installed on the South Breakwater. The tower/sensors may be moved to the East Breakwater once the Army Corps of Engineers completes the extension and alterations. o UAA and AOOS have funding for this project and would construct a prototype in the winter of 2008 and install the system in January 2009. o Responsibility and Maintenance of the Tower will not be a City function. 4 A Building Permit was issued 4-17-2007. A Certificate of Occupancy was issued 8-31-2007 and Planning and Zoning Resolution 2007-02 granted the City of Seward Harbor Department a Floodplain Variance for the project. 5Threat of landslide tsunami damage may be such that overnight occupancy by any function should be prohibited by intention and code. 6 Current fees are $30 a day for water/electricity. Proposed fee for new high end sites $50+ per night. 7 Currently Seward City Code does not permit antennas/towers/sensors in the Harbor Commercial or Park District. 240320 PACAB Work Session Laydown-Uplands Funding for Development and Installation- UAA and AOOS Management of Data, Archives and Website- AOOS Maintenance of the Tower- National Oceanic and Atmospheric Administration (NOAA) or AOOS Cost-Sharing to Fund the Project in the Future o Lease and Electrical Issues need to be discussed with appropriate departments before work begins. PARKING AND TRANSPORTATION FACILITIES Goal: Ensure safe and convenient parking and transportation services that address the needs of Seward residents, businesses and visitors. Parking Facility o Parking spaces are in high demand in the summer season for the harbor area. Currently, the Paid Parking Department uses the South Harbor Uplands Area for parking. There are a total of 189 parking sites; 20 of the sites are for 30 minute parking and 3 are ADA accessible. The other 166 sites are used for non-ADA vehicles and trailers. o A portion of the South Harbor Uplands Area would be used for parking.8 o The parking lot needs to comply with all Seward City Code requirements and a storm water system needs to be installed. o Lighting requirements need to be considered and comply with Seward City Code.9 o Parking fees are consistent with the Seward City Code § 11.15.010. See Attachment A for the Parking Fee Schedule.10 o Overnight camping, trailers and motor home parking is currently prohibited on the South Harbor Uplands Area per City policy in deference to earthquake, tsunami or other risks. Boardwalk/Bike Path 11 o Extend the boardwalk and/or bike path connections around the northern edge of the South Harbor Upland Area and extend the bike path around the 8 The parking facility will be determined by an engineering study or a TNH design concept proposal. 9 Lighting considerations: - How much, type, height, quantity and size? 10 Parking fees are amended by City Council resolution and generally discussed each fall during the upcoming fiscal year budget. 11 Potential funding could come from the Division of Parks & Outdoor Recreation Trails Grant. 240320 PACAB Work Session Laydown-Uplands southern portion of the South Harbor Uplands Area per the Boardwalk Plan/Bike Path requirements.12 o Extend the bike path from the Wellington (pavilion) picnic site along the beach and Harborside Campgrounds to the South Harbor Uplands Area.13 o The Harbor Department will be responsible for the boardwalk maintenance, and the Parks & Recreation Department will be responsible for the bike path maintenance.14 Road Access o The road access is off of Fourth Avenue, through the harbor area “Permit Only” parking lot.15 o The road will be a two way street with turn a round at the end of the uplands to allow vehicles to turn around safely.16 o The road will provide access to S, M, N, O and P floats and access to parking for the proposed handicap accessible fishing pier and allow access to slip holder parking to load/unload their supplies and equipment. o The road will comply with all fire and public safety requirements. o The road will comply with the Seward City Code requirements. o The road may need to be engineered.17 o The Public Works Department will maintain the road system. Drainage o Drainage plans need to be created to meet the Storm Water Prevention Plan Permit requirements. o Engineered drawing will be needed. 12 Update the Harborside Concept. 13 Grant money may be available from the Department of Natural Resources Division of Parks and Recreation- Recreational Trails Program. 14 The Public Works Department is seeking solution for the “fishing culverts” failure and proposals to continue to allow pedestrian connection along the waterfront. 15 The access off of Fourth Avenue also serves Harborside Campground, behind the condos. With the culvert failure, this is the only existing access. 16 Road design could change depending on the engineer study. 17 The storm drainage system may necessitate the need to engineer the road. Requirements may change if the funding for the road is Federal, State or City money. As-builts are needed. 240320 PACAB Work Session Laydown-Uplands PUBLIC FACILITIES AND SERVICES Goal: Provide quality public facilities and services to the residents, businesses and visitors of Seward. Utilities o Utility use is directly correlated to development in the South Harbor Uplands Area. Electric o The current electrical infrastructure is shown on Attachment B. o Approval from the Electric Department is required before any development occurs. Water o Water infrastructure availability is correlated with development in the South Harbor Uplands Area. o Currently, there is not water distribution system developed on the South Harbor Uplands Area. Water is available.18 o Approval from the Public Works Department is required before any development occurs. Sewage o Sewage infrastructure availability is correlated with development in the South Harbor Uplands Area. o The sewage load can only handle boats and the restroom facility located on the South Harbor Uplands Area. o Currently, there is no wastewater collection system on-site. The lift station that is on-site will accommodate some level of development- although a wastewater collection system will need to be developed. o The South Harbor Uplands Area sewage system is not consistent with the rest of the City of Seward. The Harbor Department is responsible for the sewer system on the Uplands.19 18 A limiting factor is the size of the water main (8”). 240320 PACAB Work Session Laydown-Uplands o Approval from the Public Works Department is required before any development occurs. Public Safety Fire o All development and activities on the South Harbor Uplands Area must comply with all Fire requirements found in the Seward City Code. o Approval from the Fire Department is required before any development occurs. Flood o The South Harbor Uplands area is in a Coastal High Hazard Area (FIRM “V” Zones), which means it is in high velocity waters (wind, tidal action, tsunami, etc.) creating waves of magnitude or velocity to endanger property and lives. o A Development Permit is required before beginning any structures, fill, storage of materials, drainage facilities, etc a) Construction materials and methods are regulated Anchoring on piling or columns to prevent flotation and lateral movement (100-year mean recurrence level of wind and water); fill prohibited as structural support Materials and utilities resistant to flood damage Space with breakaway panels required below (BFE) b) All construction landward of mean high tide o Floodplain management Variance Process and Procedures a) Technical evaluations and 11 standards must be addressed b) Showing of i. Good and sufficient cause ii. Exceptional hardship to the applicant iii. Variance will not result in increased flood heights c) Hearing before the Planning and Zoning Commission Natural Disaster 19 The sewer system on the South Harbor Uplands is a sewer service, which is the property owner’s responsibility. 240320 PACAB Work Session Laydown-Uplands o A Tsunami warning sign will be posted at the entrance of the South Harbor Uplands Area. o Evacuation signs from the float area and parking area will be posted. o Route directional signs will be posted. o Buildings, roads and other infrastructure should follow requirements in the Seward City Code. o An emergency siren is located next to the Harbormaster’s building. It is designated to cover all of the harbor area including the Railroad’s freight dock and past the Department of Transportation yard. Building Code o All commercial buildings built inside the City of Seward have to meet all the related requirements in the 2006 IBS for the structural related issues ETC and the amendments the City of Seward have done to the code. o An Alaska Stamped structural architectural engineered drawing is mandatory for new construction. COMMUNITY APPEARANCE Goal: Improve the appearance of the community through increased landscaping, beautification efforts and creating a user friendly environment. Aesthetics o Greenery and landscaping fitting the harsh weather and non-organic conditions should be used throughout the South Harbor Uplands Area and be managed by the City. o Landscaping should be a requirement in any private development. o Installation of decorative or theme street lights. o Have bike racks available. o Create areas between all development that is ADA and public accessible. 240320 PACAB Work Session Laydown-Uplands OTHER IDEAS Eco-Education along the Boardwalk/Bike Path o Interpretive panels located along the Boardwalk/Bike Path o Ideas include: Local Fish Species Commercial Fishing, Kayak Fishing. Subsistence Fishing in Alaska Sailing Boat Types and Styles Historical Boats (especially locals- resurrection, Alex Haley) Local military history and boats including our role in WWII 1964 Tsunami Rockwell Kent’s story Sport Fishing Tips and Tricks Local Sport Fishing success stories Climate science and how it relates to Seward o Fish Cleaning Station over by the bathrooms and the east-most ramp. *Last updated on January 29, 2009. 240320 PACAB Work Session Laydown-Uplands NOT PART OF THE PLAN- Just my thoughts Criteria for Building on the fill area… (Artists Row… or some other unified theme) Building size Building Height Mention Setback Regulations Façade theme (wood siding…) Leave an area for the public to walk through; green spaces Leave area for a Boardwalk, which the City will put in place (grant money?) Type of Businesses Exclude: Auto Services/gas station Boat Storage (competing with existing private businesses in the area and additional regulations that would be required for this area) Antenna, personal TV, satellite dish (block view) Auto/RV sales and rentals Boat sales Boat work or storage of any kind Car/boat wash Dwellings (have different building code requirements) Overnight camping (CUP) Crematory (CUP) Drive-in facility (CUP) Seafood processing (CUP) Shop (welding, wood signs etc…) (CUP) Tanks, above ground associated with service station (CUP) Approval from the Electric Department, Public Works and the Building Department Landscaping 240320 PACAB Work Session Laydown-Uplands Theresa Butts’ Idea per September 8, 2008 Email: These key features are: NW quadrant remains unobstructive of view into and out of the harbor (max 6' height on eco/education displays, lots of open space in the layout, max 6' height on greenery in this area). Include the NE corner of the employee parking lot as part of the NW quadrant of the S harbor uplands (this helps keep the view clear and gives continuity to the connection between the boardwalks and offers a good place to watch the boat ramp -- which can be quite amusing). Eco/education displays interspersed and/or bordered by attractive (though simple) landscaping. Retail opportunities encouraged east from displays to restrooms -- I suggest max 1 story (12') height (visualize these buildings from the existing boardwalk businesses, try to preserve that value). Continuity and the natural people flow is critical and should not be sacrificed for budget restrictions (it's a baby/bathwater thing) Boardwalk connects to memorial. Lead people via signage and landscaping continuity from existing developed area to display area, new retail, fish station, memorial. Much of the uplands is left undeveloped and largely unrestricted pending success of and lessons learned from new ventures. All construction and landscaping designed to last forever and be extremely low maintenance (concrete, stainless steel, plastic (recycled, like the Trex at the new playground -- although I favor real timbers for the boardwalk of course) ). An overall effect that is simple and pleasant. Secondary features are: In line with the idea of keeping the west end open to prevent view obstruction: create a secondary boardwalk with an attached green space (picnic tables, mini- amphitheater-style stone terracing recessed into ground for seating out of the wind, perhaps even a pavilion ....). Install a fishing pier (fixed, not floating) on the south side of the uplands, connected to that (new) boardwalk. Encourage a view oriented destination retail (ie restaurant) to locate between this green space/fishing pier and the memorial (leave room for future boardwalk connection). Plan to eventually connect the two boardwalks. 240320 PACAB Work Session Laydown-Uplands 240320 PACAB Work Session Laydown-Uplands 240320 PACAB Work Session Laydown-Uplands 240320 PACAB Work Session Laydown-Uplands Surveyor Structural Consultant Mechanical Consultant Electrical Consultant Ability Surveys 152 Dehel Avenue, Homer, AK 99603 l office: (907) 235-8440 l fax: (907) 235-8440 l email: gary@abilitysurveys.com Spurlock & Associates, Inc. EIC Engineers, Inc. 201 East 54th Avenue, Suite 209, Anchorage, AK 99518 l office: (907) 344-8222 l fax: (907) 344-8221 l email: tspurlock@alaska.com 6927 Old Seward Hwy, Suite 200, Anchorage, AK 99518 l office: (907) 349-9712 l fax: (907) 349-9713 l email: eric@eiceng.com Civil Consultant Nelson Engineering 155 Bidarka Street, Kenai, AK 99611 l office: (907) 283-3583 l fax: (907) 283-4514 l email: bnelson@alaska.net Nelson Engineering 155 Bidarka Street, Kenai, AK 99611 l office: (907) 283-3583 l fax: (907) 283-4514 l email: bnelson@alaska.net Architect Klauder & Company Architects, Inc. 606 Petersen Way, Kenai, AK 99611 l office: (907) 283-1919 l fax: (907) 283-0450 l email: klauder@alaska.net CONFORMED DRAWING SET G1.0 HOMER HARBOR MASTER'S OFFICE CITY OF HOMER 491 E. PIONEER AVENUE HOMER, ALASKA 99603 ISSUED FOR CONSTRUCTION COVER SHEET7-11-2014 JOB NO: 1325 The "As-Built" information was transfered from the contractor red lines by the City of Homer 11/2016. CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands 101-1 A1 A4.0 AA5.0 BUILDING SECTION KEY INTERIOR ELEVATION KEY DOOR TAG (ROOM # - DOOR #) PARTITION TYPE KEY SYMBOLS WINDOW/RELITE TYPE CENTERLINE CEILING TYPEC-1 FLOOR TYPE 1 F-1 DETAIL KEYA1.1 A1 B1 A B C D A3.0 BUILDING ELEVATION KEYA1 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 G1.1 7-11-2014 GENERAL INFORMATION ACCESSIBILITY GENERAL NOTES 1. THIS BUILDING IS DESIGNED TO COMPLY WITH THE PROVISIONS OF THE ADAAG. THIS INCLUDES, BUT IS NOT LIMITED TO, DOOR SIZES, THRESHOLDS, DOOR PULLS, DOOR HARDWARE, GRAB BARS, RESTROOM FIXTURES, TOILET PARTITIONS, ETC. THE FOLLOWING EXCERPTS FROM THE ADAAG SHALL BE APPLIED TO THIS BUILDING BUT IN NO WAY LIMIT THE APPLICABILITY OF THOSE SECTIONS NOT LISTED. 2. A "VAN ACCESSIBLE" PARKING SPACE IS PROVIDED WITH A SIGN THAT IS CLEARLY VISIBLE TO THE DRIVER OF A VEHICLE WHEN PARKING IN SUCH A LOCATION. 3. ALL OBJECTS WHICH OVERHANG OR PROTRUDE INTO CIRCULATION PATHS SHALL COMPLY WITH SECTION 4.4 OF THE ADAAG. GROUND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES SHALL COMPLY WITH 4.5 OF THE ADAAG. (ADAAG 4.1.3 ACCESSIBLE BUILDINGS: NEW CONSTRUCTION) NOTIFY ARCHITECT PRIOR TO PROCEEDING WITH WORK THAT DOES NOT COMPLY. 4. GROUND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, SLIP-RESISTANT, AND SHALL COMPLY WITH 4.5. (ADAAG 4.5.1) NOTIFY ARCHITECT PRIOR TO PROCEEDING WITH WORK THAT DOES NOT COMPLY. 5. CHANGES IN LEVEL UP TO 1/4 INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH SLOPE NO GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH ADAAG 4.7 OR.4.8. (ADAAG 4.5.2) NOTIFY ARCHITECT PRIOR TO PROCEEDING WITH WORK THAT DOES NOT COMPLY. ABBREVIATIONS ACP ACOUSTICAL CEILING PANEL AFF ABOVE FINISH FLOOR AWW ALL WEATHER WOOD CONC CONCRETE CRPT CARPET DF DRINKING FOUNTAIN DN DOWN DWG DRAWINGS ELECT ELECTRICAL FE FIRE EXTINGUISHER, WALL BRACKET MOUNTED FEC FIRE EXTINGUISHER CABINET FD FLOOR DRAIN EQ EQUAL EXP AG EXPOSED AGGREGATE GA GAUGE GLB GLULAM BEAM GWB GYPSUM WALL BOARD HB HOSE BIBB HDWR HARDWARE HR HOUR ID INTERIOR DIMENSION MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT OC ON CENTER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OH OVERHEAD OPP OPPOSITE HAND PT PRESERVATIVE TREATED SIM SIMILAR SR SHEET RUBBER SS STAINLESS STEEL SV SHEET VINYL STOR STORAGE STRUCT STRUCTURAL T&G TOUNGE AND GROOVE T.O. TOP OF TYP TYPICAL WH WATER HEATER 2009 IBC CODE DATA OCCUPANCY GROUP MIXED: BUSINESS GROUP B AND LOW-HAZARD STORAGE GROUP S-2 AUTOMATIC SPRINKLER SYSTEM NFPA 13 SYSTEM CONSTRUCTION TYPE V-B ALLOWABLE AREA 9,000 SF ACTUAL AREA 4,784 SF OCCUPANCY SEPARATIONS NONE REQUIRED NOTE SEE CODE ANALYSIS BY KLAUDER & COMPANY ARCHITECTS DATED MAY 12, 2014, SEPARATE 8 1/2"x11" DOCUMENT GENERAL NOTES 1. THESE DRAWINGS ARE "NOT FOR CONSTRUCTION" DOCUMENTS UNLESS THEY ARE CLEARLY MARKED "FOR CONSTRUCTION." DO NOT SCALE THE DRAWINGS. 2. ALL WORK SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE FOLLOWING CODES THAT HAVE BEEN ADOPTED BY THE AUTHORITY HAVING JURISDICTION IN THE PROJECT AREA: INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL FUEL GAS CODE, AND NATIONAL ELECTRICAL CODE. THESE DOCUMENTS HAVE BEEN PREPARED TO BE IN COMPLIANCE WITH THE ALL APPLICABLE CODES AS LISTED ABOVE. ADOPTION OF UPDATED OR NEW CODES SHALL REQUIRE REVIEW BY AN ARCHITECT AND ENGINEERS AS APPROPRIATE FOR THE DISCIPLINES AFFECTED. 3. THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY TO ENSURE THAT ANY WORK NOT COVERED IN THESE DOCUMENTS OR ANY MODIFICATIONS MADE DURING CONSTRUCTION ARE IN COMPLIANCE WITH ALL APPLICABLE CODES AS LISTED ABOVE. THE ARCHITECT SHALL BE NOTIFIED PRIOR TO ANY MODIFICATIONS. 4. CLEARANCE FROM COMBUSTIBLES SHALL BE PER MANUFACTURER'S WRITTEN SPECIFICATIONS. 5. ALL SUSPENDED CEILING SYSTEMS, ELECTRICAL FIXTURES, MECHANICAL DIFFUSERS, DUCTS, AND EQUIPMENT SHALL BE DESIGNED TO COMPLY WITH ASCE-7 SECTION 13.5.6. SHEET INDEX SHEET NUMBER SHEET NAME S1.0 GENERAL NOTES S2.1 FOUNDATION & OVERSLOPE PLAN S2.2 FOUNDATION FINISH PLAN S2.3 ROOF FRAMING PLAN S2.4 ROOF SHEATHING PLAN S2.5 ENLARGED FOUNDATION @ OVERSLOPE S2.6 ENLARGED ROOF FRAMING @ OVERSLOPE S2.7 ENLARGED ROOF FRAMING PLANS S3.1 BUILDING SECTION S3.2 BUILDING SECTION S4.1 DETAILS S4.2 DETAILS S4.3 DETAILS S4.4 FOUNDATION BASEPLATES S4.5 FOUNDATION BEAM SADDLES S5.1 DETAILS S5.2 DETAILS S5.3 DETAILS S5.4 DETAILS S5.5 DETAILS S5.6 DETAILS M1.1 LEGEND, ABBREVIATIONS & NOTES M1.2 MECHANICAL SCHEDULES M2.0 UNDERFLOOR PLUMBING - PLAN M2.1 PLUMBING - PLAN M3.1 HEATING - PLAN M4.1 VENTILATION - PLAN M5.1 MECHANICAL ROOF - PLAN M6.1 ENLARGED PLANS M7.1 DETAILS M7.2 PIPING SCHEMATICS E0.1 ELECTRICAL LEGEND & GENERAL REQUIREMENTS E0.2 ELECTRICAL SCHEDULES E1.1 ELECTRICAL SITE PLAN E2.1 ELECTRICAL LIGHTING PLAN E3.1 ELECTRICAL POWER & SIGNAL PLAN E3.2 ROOF POWER & SIGNAL PLAN E4.1 ELECTRICAL DIAGRAMS & DETAILS E4.2 ELECTRICAL DIAGRAMS & DETAILS E5.1 ELECTRICAL PANEL SCHEDULES SHEET INDEX SHEET NUMBER SHEET NAME G1.0 COVER SHEET G1.1 GENERAL INFORMATION V1.0 SITE SURVEY C1.0 CIVIL SITE PLAN C2.0 GRADING PLAN C3.0 UTILITIES PLAN & STORM DRAIN SYSTEM PROFILE C4.0 TYPICAL SITE SECTIONS C5.0 TYPICAL DETAILS C6.0 TYPICAL DETAILS C7.0 TYPICAL DETAILS A1.0 ARCHITECTURAL SITE PLAN - OVERALL AND SITE SECTION A1.1 ARCHITECTURAL SITE PLAN - ENLARGED A2.0 FLOOR PLAN A2.1 REFLECTED CEILING PLAN A2.2 ROOF PLAN A2.3 ENLARGED FLOOR PLAN - NW A2.4 ENLARGED FLOOR PLAN - SW A2.5 ENLARGED FLOOR PLAN - SE A2.6 ENLARGED FLOOR PLAN - NE A3.0 SOUTH ELEVATION A3.1 EAST ELEVATION A3.2 NORTH ELEVATION A3.3 ENTRY DECK ELEVATIONS A3.4 WEST ELEVATION A4.0 BUILDING SECTIONS A4.1 BUILDING SECTIONS A4.2 WALL SECTIONS A4.3 CURVED WALL DETAILS A4.4 ASSEMBLY TYPES A4.5 CASEWORK DETAILS A4.6 CEILING DETAILS A4.7 PHENOLIC PANEL DETAILS A4.8 WALL DETAILS A4.9 ROOF DETAILS A5.0 INTERIOR ELEVATIONS A5.1 INTERIOR ELEVATIONS A5.2 INTERIOR ELEVATIONS A5.3 INTERIOR ELEVATION A5.4 INTERIOR ELEVATION A5.5 INTERIOR ELEVATION A5.6 INTERIOR ELEVATIONS A6.0 DOOR SCHEDULE, DOOR AND FRAME TYPES A6.1 WINDOW/RELITE TYPES A6.2 FINISH SCHEDULE A6.3 DOOR DETAILS A6.4 DOOR AND WINDOW DETAILS A6.5 WINDOW AND RELITE DETAILS A6.6 DOOR AND WINDOW DETAILS (CONTINUED) NO. DATE 2 7-11-2014 2 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 1 1 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 1 1 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands ACGH BEF DF2 HOMER SMALL BOAT HARBOR FREIGHT DOCK ROAD PROPOSED HOMER HARBOR MASTER BUILDING PROPERTY LINE FLOATING DOCK FLOATING DOCKHOMER SMALL BOAT HARBOR KACHEMAK BAY A1 A1.0 RAMP ACCESS TO DOCKS HOMER SMALL BOAT HARBOR FREIGHT DOCK ROAD A1.1 A1 PROPOSED HOMER HARBOR MASTER BUILDING PROPERTY LINE, TYP KACHEMAK BAY KACHEMAK BAY FLOATING DOCK DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A1.0 7-11-2014 ARCHITECTURAL SITE PLAN - OVERALL AND SITE SECTION REF 1" = 40'-0" (22x34); 1" = 100'-0" (11x17)A1.0 A1 SITE SECTION 1" = 300'-0" (22x34); 1" = 600'-0" (11x17)A1.0 B1 ARCHITECTURAL SITE PLAN - OVERALL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CATCH BASIN TYP. SEE CIVIL DRAWINGS WHEEL STOP, SEE CIVIL DRAWINGS CONCRETE SIDEWALK, SEE CIVIL DRAWINGS UTILITY EASEMENT 25' - 0" RAMP ACCESS TO DOCKS CONCRETE SIDEWALK, SEE CIVIL DRAWINGS ACCESSIBLE LOADING ZONE, SEE CIVIL DRAWINGS ACCESSIBLE PARKING SPACE, TYP, SEE CIVIL DRAWINGS HOMER SMALL BOAT HARBOR 111' - 0" BOLLARD, SEE CIVIL DRAWINGS AC PAVING, SEE CIVIL DRAWINGS FREIGHT DOCK ROAD 11' - 0" PROPERTY LINE, TYP, SEE CIVIL DRAWINGS UTILITY EASEMENT 10' - 0" EAVE LINE OF EXISTING SELDOVIA FERRY OFFICE BUILDING EXISTING ELECTRICAL TRANSFORMER EXISTING COMMUNICATIONS PEDESTAL WITH TWO BOLLARDS EXISTING ELECTRICAL JUNCTION BOX 10'-0" x 10'-0" UTILITY EASEMENT EXISTING BOLLARDS, THREE EACH CONCRETE ACCESS DRIVE, SEE CIVIL DRAWINGS EXISTING ELECTRIC METER 15' - 0" DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A1.1 7-11-2014 ARCHITECTURAL SITE PLAN - ENLARGED REF 1" = 10'-0" (22x34); 1" = 20'-0" (11x17)A1.1 A1 ARCHITECTURAL SITE PLAN - ENLARGED NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FD FD FD FD FD A C G 8521 ARCTIC ENTRY 101 ENTRY HALL 102 WOMEN'S R.R. 105 JANITOR 107 STORAGE/SHOP 123 WASH DOWN PATIO 124 H LOCKER ROOM 121 A1 A4.0 C1 A4.0 A1 A4.1 HARBOR MASTER OFFICE 110 B E F 7634 74' - 0" ADMIN STORAGE 111 D F2 4.1 LOBBY 103 ADMIN HALL 104 PRINTER ALCOVE 113 MEN'S R.R. 106 MECHANICAL ROOM 120 ELECTRICAL/IT ROOM 109 ADMIN OPEN OFFICE 112 PRIVATE HALL 118 DEPUTY HARBOR MASTER OFFICE 115 MULTI-PURPOSE BREAK ROOM 116 UNISEX RESTROOM 122 17' - 7"2' - 9"9' - 10"4' - 8"11"14' - 8"5' - 5"18' - 2" 4' - 11" A2.3 A1 A2.4 A1 A2.6 A1 A2.5 A1 CONFERENCE ROOM 108 OPERATIONS 114 MEETING ROOM 119 STORAGE 117 105-1 106-1 108-1 109-1 110-1 103-1 111-1 116-1 117-1 119-1119-2 123-1 120-1 123-2 107-1 122-1 ENTRY DECK 100 110-2 10' - 0" A3.4 A3.2 A3.1 A3.0 C1 C1 C1 C1 6' - 6" 1' - 8" 1' - 6" F-1 . . F-2 A3.3 C1 A3.3 C3 LEGEND VINYL PLANK FLOORING DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.0 7-11-2014 FLOOR PLAN 3/16" = 1'-0" (22x34); 3/32" = 1'-0" (11x17)A2.0 A1 FLOOR PLAN REF GENERAL NOTES: 1. DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN, OR CENTERLINE OF OPENING UNLESS NOTED OTHERWISE. 2. SEE SHEET A4.4 FOR FLOOR TYPES F-1 3. SEE SHEET A6.0 FOR DOOR SCHEDULE. 4. SEE SHEET A6.2 FOR ROOM FINISH SCHEDULE. 5. SEE BUILDING ELEVATIONS SERIES A3 SHEETS AND INTERIOR ELEVATIONS SERIES A5 SHEETS FOR WINDOW/RELITE TYPE CALLOUTS. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 1 1 1 Record Drawings 11-20161 240320 PACAB Work Session Laydown-Uplands A C G 8521 H A1 A4.0 C1 A4.0 A1 A4.1 B E F 7634 D F2 4.1 C-1 TYP PAINT EXPOSED HVAC DUCT, SEE MECHANICAL DRAWINGS A1 A4.6 A1 A4.6 C-1 TYP A2 A4.6 C-3 C-2 C-2 C-2 C-3 SEE C1/A4.6 FOR CEILING ASSEMBLY C-3 C-3 C-3 C-3 C-1 TYP C-4C-4 C-4 C-4 C-4 C-4 C-4 C-4 A3 A4.6 C-4 A2.1 A3 C1 A4.7 10'-6" CEILING HEIGHT C2 A4.7 PHENOLIC SOFFIT PANEL STEEL COLUMN WITH HIGH PERFORMANCE COATING, SEE STRUCTURAL DRAWINGS 3/8"3/8" TYPICAL PHENOLIC SOFFIT PANEL JOINT EQ EQ DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.1 7-11-2014 REFLECTED CEILING PLAN 3/16" = 1'-0" (22x34); 3/32" = 1'-0" (11x17)A2.1 A1 REFLECTED CEILING PLAN GENERAL NOTES: 1. SEE SHEET A4.4 FOR CEILING TYPES 2. SEE FINISH SCHEDULE, SHEET A6.2, FOR CEILING HEIGHTS LEGEND 2'x4' AND 2'x2' ACP CEILING SYSTEM EXPOSED GLB'S WITH GYPSUM BOARD BETWEEN GLB'S 2'x4' LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS PENDANT, WALL SURFACE, OR CEILING SURFACE MOUNTED LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS TRACK LIGHT, SEE ELECTRICAL DRAWINGS RETURN AIR GRILLE, SEE MECHANICAL DRAWINGS SUPPLY AIR GRILLE, SEE MECHANICAL DRAWINGS EXHAUST AIR GRILLE, SEE MECHANICAL DRAWINGS CAN LIGHT, SEE ELECTRICAL DRAWINGS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A2.1 A3 COLUMN PENETRATION AT SOFFIT PANELS 240320 PACAB Work Session Laydown-Uplands A C G 8521 H A1 A4.0 C1 A4.0 A1 A4.1 B E F 7634 D F2 4.1 EPDM ROOF MEMBRANE, TYP ROOF TOP UNIT, SEE MECHANICAL DRAWINGS ROOF DRAIN & OVERFLOW ROOF DRAIN, TYP OF THREE (3), SEE MECHANICAL DRAWINGS FLEXIBLE WALKWAY VENT THRU ROOF, SEE MECHANICAL DRAWINGS ROOF ACCESS LADDER 1' - 7" 1' - 6" RIDGE LINE 3' - 6" C1 A4.9 A1 A4.9 B3 A4.9 A4.9 A4 SLOPESLOPE SLOPE SLOPE 1/4" / 12" MINIMUM B2 A4.9 PREFINISHED ALUMINUM PARAPET COPING, TYP VENT THRU ROOF, SEE MECHANICAL DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.2 7-11-2014 ROOF PLAN 3/16" = 1'-0" (22x34); 3/32" = 1'-0" (11x17)A2.2 A1 ROOF PLAN REF NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FD FD C 521 B E F 3 4 D F2 4.1 ELECTRICAL/IT ROOM 109 HARBOR MASTER OFFICE 110 JANITOR 107 MEN'S R.R. 106 WOMEN'S R.R. 105 LOBBY 103 ADMIN HALL 104 ENTRY HALL 102 1 1 1 2 4 5 6 7 8 1 3 2 4 56 7 8 9 21 1 2 3 ARCTIC ENTRY 101 1 2 CONFERENCE ROOM 108 2AC 1A 1A 2AC 1A 2AC 1F 1F 1 1A 2A 2A 1A 1A 2A 2A 2A 1A 3A 2A 2' - 6" 10B1 A B C D A B C D A1 A1 A B C1 A B A2 A4.5 3 2 4 A4 ENTRY DECK 100 1 2 1 C2 AB FLOOR ART INLAY, BY OWNER 2AG HOSE BIB, SEE MECHANICAL DRAWINGS HOSE BIB, SEE MECHANICAL DRAWINGS ELECTRICAL SERVICE EQUIPMENT, SEE ELECTRICAL DRAWINGS 2 4' - 10" 2" SLAB RECESS, SEE STRUCT DWG 3' - 6" A3 A2.3 A BB1 9 3 10 A1 A B C C3 5 1 LINE OF PARTITION BELOW COUNTER A1 A4.5 A5.0 A5.1 A5.2 A5.2 A5.0 A5.1 A5.1 A5.3 A5.3 A A A4.7 A3 TYP ABOVE DOOR 5' - 0" MIN CLEAR 33 A4.7 A4 A2 A4.5 . CONCRETE SLAB, SEE STRUCTURAL DRAWINGS GROUT OFOI SCHLUTER STRIP OFOI VINYL PLANK FLOORING FLOOR ART INLAY OFOI. LEGEND VINYL PLANK FLOORING DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.3 7-11-2014 ENLARGED FLOOR PLAN - NW REF 3/8" = 1'-0" (22x34); 3/16" = 1'-0" (11x17)A2.3 A1 ENLARGED FLOOR PLAN - NW GENERAL NOTES: 1. SEE SHEET A4.4 FOR PARTITION TYPES 2. ALL PARTITIONS FULL HEIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS SPECIFICALLY INDICATED OTHERWISE ENTRY DECK 100: 1. CARD READER, OFCI, SEE ELECTRICAL DRAWINGS 2. ADA DOOR ACTUATOR, ROUGH-IN ONLY, SEE ELECTRICAL DRAWINGS ARCTIC ENTRY 101: 1. CARD READER, OFCI, SEE ELECTRICAL DRAWINGS 2. 8'x4' BULLETIN BOARD CASE RELOCATED FROM EXISTING BUILDING, OFCI 3. ADA DOOR ACTUATOR, ROUGH-IN ONLY, SEE ELECTRICAL DRAWINGS ENTRY HALL 102: 1. 8'x4' BULLETIN BOARD CASE RELOCATED FROM EXISTING BUILDING, OFCI 2. ADA DOOR ACTUATOR, ROUGH-IN ONLY, SEE ELECTRICAL DRAWINGS LOBBY 103: 1. FUTURE WALL MOUNTED FLAT SCREEN MONITOR, ROUGH-IN ONLY, SEE ELECTRICAL DRAWINGS 2. SOLID SURFACE COUNTERTOP 3. CABLE PASS THROUGH HOLE IN COUNTERTOP WITH GROMMET, COORDINATE LOCATION WITH OWNER ADMIN HALL 104: 1. CARD READER, OFCI, SEE ELECTRICAL DRAWINGS WOMEN'S R.R. 105: 1. WATER CLOSET, SEE MECHANICAL DRAWINGS 2. LAVATORY, SEE MECHANICAL DRAWINGS 3. RECESSED SANITARY NAPKIN/TAMPON VENDOR 4. SS GRAB BARS 5. 24" x 42" MIRROR WITH SS FRAME 6. SOAP DISPENSER, OFCI 7. PAPER TOWEL DISPENSER, OFCI 8. TOILET TISSUE DISPENSER 9. TOILET SEAT COVER DISPENSER 10. SANITARY NAPKIN DISPOSAL MEN'S R.R. 106: 1. WATER CLOSET, SEE MECHANICAL DRAWINGS 2. URINAL, SEE MECHANICAL DRAWINGS 3. LAVATORY, SEE MECHANICAL DRAWINGS 4. TOILET COMPARTMENT 5. SS GRAB BARS 6. 24" x 42" MIRROR WITH SS FRAME 7. SOAP DISPENSER, OFCI 8. PAPER TOWEL DISPENSER, OFCI 9. TOILET TISSUE DISPENSER 10. TOILET SEAT COVER DISPENSER JANITOR 107: 1. SHELF WITH MOP AND BROOM HOLDER 2. FLOOR SINK, SEE MECHANICAL DRAWINGS CONFERENCE ROOM 108: 1. FLAT SCREEN MONITOR WITH WALL MOUNT BRACKET, OFCI, SEE ELECTRICAL DRAWINGS 2. PULL-OUT WASTE CONTAINER BASE CABINET 3. UPPER CABINETS, BASE CABINETS, AND SOLID SURFACE COUNTERTOP WITH BACKSPLASH 4. SINK, SEE MECHANICAL DRAWINGS 5. WARDROBE CABINET HARBOR MASTER OFFICE 110: 1. CLOSET ORGANIZER SYSTEM 6" = 1'-0" (22x34); 3" = 1'-0" (11x17)A2.3 A3 FLOOR TRANSITION DETAIL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION KEY PLAN 240320 PACAB Work Session Laydown-Uplands G 21 H F 3 4 F2 4.1 ADMIN STORAGE 111 ADMIN OPEN OFFICE 112 PRINTER ALCOVE 113 2 A2 A4.2 SIM VINYL FEATURE STRIP 1AC 1AC (NO COUNTERTOP) 4' - 0" A2.4 B3 A1 A B A5.6 A4.7 A3 TYP A4.7 C3 A6.6 A1 2 F2 2" VINYL FEATURE STRIP CARPET TILE C3 A2.4 1" VINYL FEATURE STRIP CARPET TILE VINYL PLANK FLOORING CONCRETE SLAB, SEE STRUCTURAL DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.4 7-11-2014 ENLARGED FLOOR PLAN - SW 3/8" = 1'-0" (22x34); 3/16" = 1'-0" (11x17)A2.4 A1 ENLARGED FLOOR PLAN - SW REF GENERAL NOTES: 1. SEE SHEET A4.4 FOR PARTITION TYPES 2. ALL PARTITIONS FULL HEIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS SPECIFICALLY INDICATED OTHERWISE 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A2.4 B3 FLOOR TRANSITION DETAIL REF 6" = 1'-0" (22x34); 3" = 1'-0" (11x17)A2.4 C3 FLOOR TRANSITION DETAIL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION LEGEND VINYL PLANK FLOORING KEY PLAN 240320 PACAB Work Session Laydown-Uplands G 85 H E F 764 F2 4.1 A2 A4.2 PRIVATE HALL 118 MULTI-PURPOSE BREAK ROOM 116 DEPUTY HARBOR MASTER OFFICE 115 WASH DOWN PATIO 124 2 3 1 1 2 STORAGE 117 OPERATIONS 114 2AE 2ACE 1ACE 2ACD 1ACD 2A 1A 1A 4A A1 A B 1 1 HOSE BIB, SEE MECHANICAL DRAWINGS B3 A4.3 A B A1 B C1 A A5.2 A5.4 A5.6 A4.7 A3 A4.7 C3 3 3 3 3 3 3 3 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.5 7-11-2014 ENLARGED FLOOR PLAN - SE REF 3/8" = 1'-0" (22x34); 3/16" = 1'-0" (11x17)A2.5 A1 ENLARGED FLOOR PLAN - SE GENERAL NOTES: 1. SEE SHEET A4.4 FOR PARTITION TYPES 2. ALL PARTITIONS FULL HEIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS SPECIFICALLY INDICATED OTHERWISE OPERATIONS 114: 1. SOLID SURFACE COUNTERTOP 2. VERTICAL PARTITION 3. CABLE PASS THROUGH HOLE IN COUNTERTOP WITH GROMMET, COORDINATE LOCATION WITH OWNER MULTI-PURPOSE BREAK ROOM 116: 1. PULL-OUT WASTE CONTAINER IN BASE CABINET 2. UPPER CABINETS, BASE CABINETS, AND SOLID SURFACE COUNTERTOP WITH BACKSPLASH 3. SINK WITH OFCI GARBAGE DISPOSAL, SEE MECHANICAL AND ELECTRICAL DRAWINGS WASH DOWN PATIO 124: 1. CARD READER, OFCI, SEE ELECTRICAL DRAWINGS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION LEGEND VINYL PLANK FLOORING KEY PLAN 240320 PACAB Work Session Laydown-Uplands FD FD FD A C 85 B E 76 D LOCKER ROOM 121 STORAGE/SHOP 123 UNISEX RESTROOM 122 MECHANICAL ROOM 120 PRIVATE HALL 118 WASH DOWN PATIO 124 1 1 2 3 4 5 6 12 3 4 6 7 895 MEETING ROOM 119 ELEVATOR PIT BELOW FOR FUTURE ELEVATOR, SEE STRUCTURAL DRAWINGS 1AE1AE2ACE 1BF 2A 1AD 2AE1AE 1AE 1AE 2A 2AE 1AE 2AE C1 A B C D 3 2 1 2222 2 2 2 1 1 1 1 1 1 1 ROOF ACCESS LADDER, SEE B2/A4.72AD HOSE BIB, SEE MECHANICAL DRAWINGS 10 EQEQ A B C D AB BOLLARD, SEE CIVIL DRAWINGS 11 SLOPE SLOPE SLOPE TYP A1 B1 SLOPE SLOPE SLOPE SLOPE A5.1 A5.5 A5.4 A4.7 A3 TYP A4.7 A4 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A2.6 7-11-2014 ENLARGED FLOOR PLAN - NE REF 3/8" = 1'-0" (22x34); 3/16" = 1'-0" (11x17)A2.6 A1 ENLARGED FLOOR PLAN - NE GENERAL NOTES: 1. SEE SHEET A4.4 FOR PARTITION TYPES 2. ALL PARTITIONS FULL HEIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS SPECIFICALLY INDICATED OTHERWISE LOCKER ROOM 121: 1. (8) LARGE METAL LOCKERS (24" x 24") 2. (8) SMALL METAL LOCKERS (18" x 18") 3. BENCH (10" WIDE x 6' LONG) UNISEX RESTROOM 122 1. SHOWER ENCLOSURE AND BASE, SEE MECHANICAL DRAWINGS 2. SOAP DISPENSER, OFCI 3. PAPER TOWEL DISPENSER, OFCI 4. 24" x 42" MIRROR WITH SS FRAME 5. TOILET SEAT COVER DISPENSER 6. LAVATORY, SEE MECHANICAL DRAWINGS 7. URINAL, SEE MECHANICAL DRAWINGS 8. WATER CLOSET, SEE MECHANICAL DRAWINGS 9. TOILET TISSUE DISPENSER 10. SS GRAB BARS 11. SANITARY NAPKIN DISPOSAL STORAGE/SHOP 123: 1. WALL MOUNTED HARDWARE BIN STORAGE, OFCI 2. FLOOR MOUNTED AIR COMPRESSOR WITH OVERHEAD LINES, OFCI, SEE MECHANICAL AND ELECTRICAL DRAWINGS 3. POWER TOOL CABINET, OFCI 4. UTILITY SINK, SEE MECHANICAL DRAWINGS 5. PAINT STORAGE CABINET, OFCI 6. EVAPORATOR PIT WITH STEEL GRATE, SEE STRUCTURAL DRAWINGS WASH DOWN PATIO 124: 1. CARD READER, OFCI, SEE ELECTRICAL DRAWINGS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION LEGEND VINYL PLANK FLOORING KEY PLAN 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" 8521 T.O. PARAPET 114' - 9" 76344.1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #3 PHENOLIC WALL PANEL, COLOR #1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #2 PHENOLIC WALL PANEL, COLOR #1 PREFINISHED ALUMINUM PARAPET COPING TO MATCH PHENOLIC WALL PANEL COLOR #2 ROOF ACCESS LADDER ALUMINUM WINDOW SYSTEM PROTECTION BOARD EQ 1 4' - 0"4' - 0"EQ 1 EQ 2 4' - 0" EQ 2 ON CURVED WALL ALIGN VERTICAL PANEL JOINTS WITH STEEL COLUMNS, SEE STRUCTURAL DRAWINGS FINISH GRADE, SEE CIVIL DRAWINGS D 3/8" PHENOLIC WALL PANEL VERTICAL JOINT, TYP, SEE A1/A4.7 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 ROOF TOP UNIT, SEE MECHANICAL DRAWINGS EXPOSED CONCRETE COLUMN, TYP, SEE STRUCTURAL DRAWINGS COMPUTER ROOM UNIT, SEE MECHANICAL DRAWINGS ELECTRIC SERVICE EQUIPMENT, SEE ELECTRICAL DRAWINGS LIGHT FIXTURE, TYP, SEE ELECTRICAL DRAWINGS PROTECTION BOARD PHENOLIC WALL PANEL ACCENT BAND, COLOR #3, TERMINATE 2" ABOVE FINISH GRADE 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 SIREN, SEE ELECT DRAWINGS ROOF ACCESS LADDER PLATFORM ROOF ACCESS LADDER GRAB BARS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A3.0 7-11-2014 SOUTH ELEVATION 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A3.0 C1 SOUTH ELEVATION GENERAL NOTES: 1. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES. 2. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" ACGH T.O. PARAPET 114' - 9" BEFDF2 ALUMINUM WINDOW SYSTEM, TYP ROOF ACCESS LADDER ACCESS LADDER SECURITY DOOR PHENOLIC WALL PANEL ACCENT BAND, COLOR #3 PHENOLIC WALL PANEL, COLOR #1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #2 PHENOLIC WALL PANEL, COLOR #1 PREFINISHED ALUMINUM PARAPET COPING TO MATCH PHENOLIC WALL PANEL COLOR #2 EQ 14' - 0"EQ 1 4' - 0" HOSE BIBB,SEE MECHANICAL DRAWINGS HOSE BIBB,SEE MECHANICAL DRAWINGS EXPOSED CONCRETE COLUMN, TYP, SEE STRUCTURAL DRAWINGS 4' - 0" SPACING CONTINOUS . 4' - 0" .SPACING CONTINOUS D E B 3/8" PHENOLIC WALL PANEL VERTICAL JOINT, TYP, SEE A1/A4.7 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 ROOF TOP UNIT, SEE MECHANICAL DRAWINGS LIGHT FIXTURE, TYP, SEE ELECTRICAL DRAWINGS POWER RECEPTACLE, TYP, SEE ELECTRICAL DRAWINGS BOILER WALL KIT,SEE MECH DRAWINGS LOUVER,SEE MECHANICAL DRAWINGS CLOTHES DRYER VENT WALL CAP,SEE MECH DRAWINGS GAS METER,SEE MECH DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A3.1 7-11-2014 EAST ELEVATION 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A3.1 C1 EAST ELEVATION GENERAL NOTES: 1. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES. 2. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" 8 5 2 1 T.O. PARAPET 114' - 9" 7 6 344.1 ALUMINUM WINDOW SYSTEM, TYP PHENOLIC WALL PANEL ACCENT BAND, COLOR #3 PHENOLIC WALL PANEL, COLOR #1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #2 PHENOLIC WALL PANEL, COLOR #1 PREFINISHED ALUMINUM PARAPET COPING TO MATCH PHENOLIC WALL PANEL COLOR #2 STEEL COLUMN WITH HIGH PERFORMANCE COATING, TYP, SEE STRUCTURAL DRAWINGS HOSE BIBB, SEE MECHANICAL DRAWINGS EQ 3 4' - 0"4' - 0"4' - 0"4' - 0"EQ 3EQ 1 4' - 0"4' - 0"4' - 0"4' - 0" EQ 1 ROOF ACCESS LADDER 4' - 0" EQ 2 SPACING CONTINOUS . EQ 2 4' - 0" .SPACING CONTINOUS A SIREN, SEE ELECTRICAL DRAWINGS 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 ROOF TOP UNIT, SEE MECHANICAL DRAWINGS OVERFLOW ROOF DRAIN SPOUT, SEE MECHANCIAL DRAWINGS ANODIZED ALUMINUM FRAMED ENTRANCE COMPUTER ROOM UNIT, SEE MECHANICAL DRAWINGS ELECTRIC SERVICE EQUIPMENT, SEE ELECTRICAL DRAWINGS LIGHT FIXTURE, TYP, SEE ELECTRICAL DRAWINGS PROTECTION BOARD COMPRESSED AIR OUTLET, SEE MECHANCIAL DRAWINGS POWER RECEPTACLE, TYP, SEE ELECTRICAL DRAWINGS 3/8" PHENOLIC WALL PANEL VERTICAL JOINT, TYP, SEE A1/A4.7 LIGHT FIXTURE, TYP, SEE ELECTRICAL DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A3.2 7-11-2014 NORTH ELEVATION 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A3.2 C1 NORTH ELEVATION GENERAL NOTES: 1. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES. 2. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" A T.O. PARAPET 114' - 9" B CIRCULAR WINDOW EQ 1 4' - 0"4' - 0"4' - 0"4' - 0"EQ 1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #3 PHENOLIC WALL PANEL, COLOR #1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #2 PHENOLIC WALL PANEL, COLOR #1 PREFINISHED ALUMINUM PARAPET COPING TO MATCH PHENOLIC WALL PANEL COLOR #2 C 3/8" PHENOLIC WALL PANEL VERTICAL JOINT, TYP, SEE A1/A4.7 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 PROTECTION BOARD LIGHT FIXTURE, SEE ELECT DRAWINGS COMPRESSED AIR OUTLET, SEE MECHANICAL DRAWINGS OVERFLOW ROOF DRAIN SPOUT, SEE MECHANCIAL DRAWINGS POWER RECEPTACLE, SEE ELECTRICAL DRAWINGS EQ2EQ2 T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" C T.O. PARAPET 114' - 9" B EQ 14' - 0"4' - 0"EQ 1 CIRCULAR WINDOW PHENOLIC WALL PANEL ACCENT BAND, COLOR #3 PHENOLIC WALL PANEL, COLOR #1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #2 PHENOLIC WALL PANEL, COLOR #1 PREFINISHED ALUMINUM PARAPET COPING TO MATCH PHENOLIC WALL PANEL COLOR #2 C 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 3/8" PHENOLIC WALL PANEL VERTICAL JOINT, TYP, SEE A1/A4.7 PROTECTION BOARD EQ2EQ2 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A3.3 7-11-2014 ENTRY DECK ELEVATIONS 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A3.3 C1 ENTRY DECK ELEVATION EAST 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A3.3 C3 ENTRY DECK ELEVATION WEST GENERAL NOTES: 1. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES. 2. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" A C G H T.O. PARAPET 114' - 9" B E FD F2 ALUMINUM WINDOW SYSTEM, TYP PHENOLIC WALL PANEL ACCENT BAND, COLOR #3 PHENOLIC WALL PANEL, COLOR #1 PHENOLIC WALL PANEL ACCENT BAND, COLOR #2 PHENOLIC WALL PANEL, COLOR #1 PREFINISHED ALUMINUM PARAPET COPING TO MATCH PHENOLIC WALL PANEL COLOR #2 EXPOSED CONCRETE COLUMN, TYP, SEE STRUCTURAL DRAWINGS HOSE BIBB, SEE MECHANICAL DRAWINGS EQ 1 4' - 0"EQ 14' - 0" .SPACING CONTINOUS SPACING CONTINOUS . A B D 3/8" PHENOLIC WALL PANEL VERTICAL JOINT, TYP, SEE A1/A4.7 3/8" PHENOLIC WALL PANEL HORIZONTAL JOINT, SEE A2/A4.7 ROOF TOP UNIT, SEE MECHANICAL DRAWINGS COMPUTER ROOM UNIT, SEE MECHANICAL DRAWINGS ELECTRIC SERVICE EQUIPMENT, SEE ELECTRICAL DRAWINGS LINE OF BUILDING BEYOND LIGHT FIXTURE, TYP, SEE ELECTRICAL DRAWINGS POWER RECEPTACLE, TYP, SEE ELECTRICAL DRAWINGSPROTECTION BOARD DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A3.4 7-11-2014 WEST ELEVATION 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A3.4 C1 WEST ELEVATION GENERAL NOTES: 1. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES. 2. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" ACGH C1 A4.0 A1 A4.1 T.O. PARAPET 114' - 9" BEFDF2 CEILING, TYP ROOF STRUCTURE, TYP, SEE STRUCTURAL DRAWINGS TYP ROOF ASSEMBLY, SEE A1/A4.2 CURVED SOLID PHENOLIC EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 ALUMINUM WINDOW SYSTEM CONCRETE SLAB ON METAL DECK, SEE STRUCTURAL DRAWINGS ADMIN OPEN OFFICE 112 LOBBY 103 ENTRY HALL 102 ARCTIC ENTRY 101 ENTRY DECK 100 A4.2 A2 SIM (NO COUNTERTOP) A4.2 A3 CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS STEEL COLUMN WITH HIGH PERFORMANCE COATING, SEE STRUCTURAL DRAWINGS EXPOSED CONCRETE COLUMN, SEE STRUCT DWG INSULATED CONCRETE FORM FOUNDATION WALL, SEE STRUCT DWG A4.6 A2 SIM, OPP A4.6 A2 SIM T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" 8 5 2 1 A1 A4.0 T.O. PARAPET 114' - 9" 7 6 344.1 CEILING, TYP ROOF STRUCTURE, TYP, SEE STRUCTURAL DRAWINGS TYP ROOF ASSEMBLY, SEE A1/A4.2 TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 ALUMINUM WINDOW SYSTEM CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS MULTI-PURPOSE BREAK ROOM 116 STORAGE 117 LOBBY 103 HARBOR MASTER OFFICE 110 ADMIN HALL 104 A4.2 A1 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.0 7-11-2014 BUILDING SECTIONS 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A4.0 A1 BUILDING SECTION 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A4.0 C1 BUILDING SECTION GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 2. ALL PARTITIONS EXTEND TO UNDERSIDE OF STRUCTURE UNLESS SPECIFICALLY SHOWN OTHERWISE. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" 8 5 2 1 A1 A4.0 T.O. PARAPET 114' - 9" 7 6 344.1 A4.2 A1 CEILING, TYP ROOF STRUCTURE, TYP, SEE STRUCTURAL DRAWINGS TYP ROOF ASSEMBLY, SEE A1/A4.2 TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 ALUMINUM WINDOW SYSTEM CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS STORAGE/SHOP 123 LOCKER ROOM 121 ARCTIC ENTRY 101 MEN'S R.R. 106 ADMIN HALL 104 CONFERENCE ROOM 108 A4.6 C1 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.1 7-11-2014 BUILDING SECTIONS 1/4" = 1'-0" (22x34); 1/8" = 1'-0" (11x17)A4.1 A1 BUILDING SECTION GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 2. ALL PARTITIONS EXTEND TO UNDERSIDE OF STRUCTURE UNLESS SPECIFICALLY SHOWN OTHERWISE. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands TYP EXTERIOR WALL ASSEMBLY: SOLID PHENOLIC EXTERIOR WALL PANELS OVER ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING, OVER WEATHER BARRIER OVER OSB WALL SHEATHING, SEE STRUCT DWG, OVER WOOD STUDS, SEE STRUCT DWG, WITH TWO LAYERS R-15 BATT INSULATION IN STUD CAVITY OVER WALL VAPOR RETARDER OVER 1/2" GYPSUM WALL BOARD WALL BASE, AS SCHEDULED CONCRETE SLAB ON GRADE, SEE STRUCT DWG TYP ROOF ASSEMBLY: EPDM ROOF MEMBRANE OVER 1/2" COVER BOARD OVER TAPERED ROOF INSULATION OVER BASE LAYER OF ROOF INSULATION OVER ROOF VAPOR RETARDER OVER PLYWOOD ROOF SHEATHING, SEE STRUCT DWG OVER ROOF STRUCTURE, SEE STRUCT DWG FINISH GRADE, SEE CIVIL DWG PROTECTION BOARD 2" RIGID PERIMETER INSULATION PREFINISHED ALUMINUM PARAPET COPING A4.8 B1 A4.8 A2 A4.8 A1 SOLID PHENOLIC EXTERIOR WALL PANELS ON 2 1/2" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 2" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING 2' - 0" HORIZONTAL PANEL JOINT 5/8" TYPE X GYPSUM BOARD T.O. SLAB 100' - 0" T.O. STRUCTURE 113' - 0" T.O. PARAPET 114' - 9" A4.3 A1 ALUMINUM WINDOW SYSTEM CURVED EXTERIOR WALL ASSEMBLY: CURVED SOLID PHENOLIC EXTERIOR WALL PANELS OVER ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING, OVER WEATHER BARRIER OVER CURVED OSB WALL SHEATHING, SEE STRUCT DWG, OVER 2x4 WOOD STUDS @ 8" OC, SEE STRUCT DWG, WITH R-15 BATT INSULATION IN STUD CAVITY OVER 1/4" AIR SPACE OVER 2x4 WOOD STUDS @ 8" OC, SEE STRUCT DWG, WITH R-15 BATT INSULATION IN STUD CAVITY OVER WALL VAPOR RETARDER OVER CURVED 1/2" GYPSUM WALL BOARD - DRY BEND PREFINISHED ALUMINUM PARAPET COPING CURVED SOLID PHENOLIC EXTERIOR WALL PANELS ON 2 1/2" ALUMINUM SUB- FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING CURVED SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING CURVED SOLID PHENOLIC EXTERIOR WALL PANELS ON 2" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING CURVED SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING HORIZONTAL PANEL JOINT CURVED SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING A4.8 A1 A4.8 B1 EXPOSED CONCRETE COLUMN, SEE STRUCTURAL DRAWINGS TYP ROOF ASSEMBLY, SEE A1/A4.2 CONCRETE SLAB ON METAL DECK, SEE STRUCT DWG SIM 5/8" TYPE X GYPSUM BOARD UNDER 1x4 WOOD FURRING STRIPS @ 24" OC ENTRY DECK 100 T.O. STRUCTURE PHENOLIC SOFFIT PANELS UNDER 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING, UNDER WEATHER BARRIER UNDER 1/2" PLYWOOD SHEATHING UNDER 2X6 JOISTS, SEE STRUCT DWG 4x8 TUBE STEEL COLUMN WITH HIGH PERFORMANCE COATING, SEE STRUCTURAL DRAWINGS TYP ROOF ASSEMBLY, SEE A1/A4.2 A4.8 B1 SIM, OPP PREFINISHED ALUMINUM PARAPET COPING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING PREFINISHED ALUMINUM PARAPET COPING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB- FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 2" ALUMINUM SUB- FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB- FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING ALUMINUM ENTRANCE SYSTEM EPDM MEMBRANE, EXTEND UP WALL TO A POINT 6" ABOVE BOTTOM OF PHENOLIC WALL PANEL, EXTEND UNDER WEATHER BARRIER CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS EXPANSION JOINT, SEE STRUCTURAL DRAWINGS 2" RIGID PERIMETER INSULATION2' - 0" DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.2 7-11-2014 WALL SECTIONS 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.2 A1 WALL SECTION - TYPICAL 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.2 A2 WALL SECTION AT CURVED WALL 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.2 A3 WALL SECTION AT ENTRY DECK GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands 2 LAYERS 3/4" PT PLYWOOD BOTTOM PLATE, CUT TO WALL CURVE BASEBOARD HEAT SYSTEM, SEE MECHANICAL DRAWINGS WOOD TRIM 2x6 WOOD STUDS @ 8" O.C. 2 1/2" x 2 1/2" x 1/4" STEEL ANGLE COUNTERTOP BRACKET @ 48" OC, PAINT TO MATCH WALL PAINT CURVED 1/2" GYPSUM WALL BOARD - DRY BEND 3/4" THICK CURVED SOLID SURFACE COUNTERTOP WITH EASED EDGE VENTED SOLID SURFACE SILL WITH BULLNOSE EDGE 2 LAYERS 3/4" PT PLYWOOD TOP PLATE, CUT TO WALL CURVE PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1/2" OVER PHENOLIC PANEL BELOW, COLOR TO MATCH PHENOLIC WALL PANEL ACCENT BAND COLOR #3 CURVED SOLID PHENOLIC EXTERIOR WALL ASSEMBLY, SEE A2/A4.2 A4.3 A3 CURVED 1/2" GYPSUM WALL BOARD - DRY BEND 3/4" DIAMETER THROUGH BOLTS TO STUDS 3/4" PLYWOOD SIMPSON H3 STRAP AT EACH STUD WITH STEEL ANGLE, ATTACH TO BOTTOM OF CURVED PLATE 2' - 6" 6" PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1/2" OVER PHENOLIC PANEL BELOW, COLOR TO MATCH PHENOLIC PANEL COLOR #1 PREFINISHED BLACK PERFORATED ALUMINUM CLOSURE FLASHING WEATHER BARRIER, EXTEND TO BOTTOM OF WALL SHEATHING CURVED OSB WALL SHEATHING, SEE STRUCTURAL DRAWINGS BLOCKING, SEE STRUCTURAL DRAWINGS, ALIGN WITH PANEL JOINTS EXPOSED CONCRETE COLUMN, SEE STRUCTURAL DRAWINGS CURVED PT PLATE, SEE STRUCTURAL DRAWINGS CURVED PLATE, SEE STRUCTURAL DRAWINGS RIGID PERIMETER INSULATION, THICKNESS VARIES BEAM SADDLE, SEE STRUCTURAL DRAWINGS GLU LAM BEAM, SEE STRUCTURAL DRAWINGS CEDAR 1x6, SEE STRUCTURAL DRAWINGS 7" SPRAY POLYURETHANE FOAM INSULATOIN POLYUREA INSULATION COATING CONCRETE SLAB ON METAL DECK, SEE STRUCTURAL DRAWINGS, SEE FINISH SCHEDULE FOR FLOOR FINISH A4.3 B4 VENT SLOTS, 5" LONG, 8" OC, CENTERED BETWEEN STUDS VENTED SOLID SURFACE SILL WITH BULLNOSE EDGE 2 1/4" 1/4" 1/2" 1/4" 1/2" 1/4" 1/2" 1/4" 1/2"1/4" 1/2" 1/4" CUT OPENING IN BOTH PLYWOOD TOP PLATES, 5 1/2" LONG, 8" OC, CENTERED BETWEEN STUDS 1"4 1/2" 1/2" SEALANT ALUMINUM WINDOW SYSTEM WALL VAPOR RETARDER, SEAL TO WOOD WINDOW SILL FRAMING CURVED PLATE, SEE STRUCTURAL DRAWINGSCURVED EXTERIOR WALL ASSEMBLY, SEE A2/A4.2 GLASS AS SCHEDULED, SEE SHEET A6.1 BACKER ROD AND SEALANT WEATHER BARRIER FLASHING AT JAMB, WRAP OVER WEATHER BARRIER WEATHER BARRIER CURVED SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING VARIES PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1/2" OVER PHENOLIC PANEL BELOW, COLOR TO MATCH PHENOLIC PANEL COLOR #1 T.O. SLAB 100' - 0" 1 1/2" THICK SOLID SURFACE PARTITION WITH EASED EDGES SOLID SURFACE COUNTERTOP 2" x 2" x 1/8" STEEL ANGLE EACH SIDE, PAINT TO MATCH WALL PAINT 2" x 2" x 1/8" STEEL ANGLE EACH SIDE, PAINT TO MATCH WALL PAINT EXTEND CARPET TILES OVER STEEL ANGLES 3/4" PLYWOOD CURVED 1" THICK WOOD TRIM WITH SEMI-TRANSPARENT STAIN FINISH, TYP 1/4" BEVELED EDGE, TYP DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.3 7-11-2014 CURVED WALL DETAILS 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.3 A1 CURVED WALL BASE DETAIL 6" = 1'-0" (22x34); 3" = 1'-0" (11x17)A4.3 A3 VENTED SOLID SURFACE SILL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.3 B3 CURVED WORK COUNTER DETAIL GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 6" = 1'-0" (22x34); 3" = 1'-0" (11x17)A4.3 B4 TRIM DETAIL WOOD BASEBOARD NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands 1/2" GYPSUM WALL BOARD OVER 2x4 WOOD STUDS @ 24" OC OVER 1/2" GYPSUM WALL BOARD 1 2 1/2" GYPSUM WALL BOARD OVER 2x6 WOOD STUDS @ 24" OC OVER 1/2" GYPSUM WALL BOARD 3 4 1' - 0"1' - 2" 1/2" GYPSUM WALL BOARD OVER 2x6 WOOD STUDS @ 24" OC OVER 1/2" GYPSUM WALL BOARD AIR SPACE OVER 2x6 WOOD STUDS @ 24" OC OVER 1/2" GYPSUM WALL BOARD OVER 2x4 WOOD STUDS @ 24" OC OVER 1/2" GYPSUM WALL BOARD AIR SPACE OVER 2x4 WOOD STUDS @ 24" OC OVER CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS F-1 CONCRETE SLAB ON METAL DECKING, SEE STRUCTURAL DRAWINGS, OVER 7" SPRAY POLYURETHANE FOAM INSULATOIN, OVER POLYUREA INSULATION COATING F-2 FLOOR FINISH, AS SCHEDULED, OVER FLOOR FINISH, AS SCHEDULED, OVER SLAB VAPOR RETARDER 2" SAND, SEE STRUCTURAL DRAWINGS ROOF VAPOR RETARDER OVER C-1 ROOF FRAMING, SEE STRUCT DWG, OVER 5/8" TYPE X GYPSUM BOARD C-2 RIGID ROOF INSULATION OVER 5/8" TYPE X GYPSUM BOARD 1x4 WOOD FURRING STRIPS @ 24" OC OVEREXPOSED GLU LAM BEAM WITH CLEAR TRANSPARENT FINISH, SEE STRUCTURAL DRAWINGS 1" QUARTER ROUND WOOD TRIM WITH SEMI- TRANSPARENT STAIN FINISH AT EACH SIDE OF BEAM PLYWOOD ROOF SHEATHING, SEE STRUCTURAL DRAWINGS, OVER ROOF FRAMING, SEE STRUCT DWG, OVER 5/8" TYPE X GYPSUM BOARD OVER C-3 7/8" HAT CHANNELS AT 16" OC OVER 3" CARRYING CHANNELS AT 48" OC OVER RETURN AIR PLENUM OVER WIRE HANGERS ROOF FRAMING, SEE STRUCT DWG, OVER 5/8" TYPE X GYPSUM BOARD OVER C-4 ACOUSTICAL CEILING PANELS METAL SUSPENSION SYSTEM OVER RETURN AIR PLENUM OVER WIRE HANGERS 5/8" TYPE X GYPSUM BOARD DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.4 7-11-2014 ASSEMBLY TYPES 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17) PARTITION TYPES PARTITION TYPE MODIFICATIONS A ADD 3 1/2" SOUND ATTENUATION BLANKET IN STUD CAVITY OF 2x4 WOOD STUD PARTITIONS OR 5 1/2" SOUND ATTENUATION BLANKET IN STUD CAVITY OF 2x6 WOOD STUD PARTITIONS, IN WALLS WITH TWO STUD CAVITIES ADD SOUND ATTENUATION BLANKET IN BOTH STUD CAVITIES B OMIT 1/2" GYPSUM WALL BOARD ON ONE SIDE OF PARTITION ONLY C ADD WALL SHEATHING BETWEEN WOOD STUD AND GYPSUM WALL BOARD ON ONE SIDE OF PARTITION ONLY, SEE STRUCTURAL DRAWINGS D REPLACE 1/2" GYPSUM WALL BOARD WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE OF PARTITION ONLY E REPLACE 1/2" GYPSUM WALL BOARD WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES OF PARTITION, 1 HOUR FIRE RATED WALL UL DESIGN NUMBER U314 F PARTITION TO EXTEND TO UNDERSIDE OF FINISHED CEILING ONLY G REPLACE 1/2" GYPSUM WALL BOARD WITH TWO LAYERS OF 1/4" FLEXIBLE GYPSUM WALL BOARD - WET BEND ON BOTH SIDES OF PARTITION, CHANGE WOOD STUD SPACING TO 6" OC PARTITION TYPE NOTES: 1. ALL PARTITIONS ARE TO BE FULL HEIGHT TO STRUCTURE ABOVE UNLESS INDICATED OTHERWISE. 2. SEE PARTITION TYPE MODIFICATIONS FOR ALL MODIFICATIONS TO BASIC PARTITIONS. 3. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF BEARING WALLS AND SHEAR WALLS. 4. SEE ROOM FINISH SCHEDULE SHEET A6.2 FOR LOCATIONS OF MOISTURE RESISTANT GYPSUM BOARD. 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17) FLOOR TYPES CEILING TYPE NOTES: 1. SEE REFLECTED CEILING PLAN (A1/A2.1) FOR CEILING HEIGHTS. 2. NO COMBUSTIBLES ARE PERMITTED IN THE RETURN AIR PLENUM. 3. SEISMICALLY BRACE ALL SUSPENDED CEILING AND SOFFIT SYSTEMS PER IBC SECTION 1613. 4. SEE FINISH SCHEDULE SHEET A6.2 FOR ACOUSTICAL CEILING PANEL AND CEILING FINISHES. 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17) CEILING TYPES FLOOR TYPE NOTE: 1. SEE FINISH SCHEDULE SHEET A6.2 FOR FLOOR FINISH. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" OPEN BELOW COUNTER 3/4" SOLID SURFACE COUNTERTOP WITH EASED EDGE 3/4" PLYWOOD PARTITION TYPE 1 WALL BASE, AS SCHEDULED WALL BASE, AS SCHEDULED 3/4" SOLID SURFACE COUNTERTOP WITH EASED EDGE 3/4" PLYWOOD ADJUSTABLE SHELF ADJUSTABLE SHELF BASE SHELF VERTICAL SUPPORT BEYOND WALL BASE, AS SCHEDULED ADJUSTABLE SHELF DRAWER SOLID SURFACE COUNTERTOP AND BACKSPLASH WITH EASED EDGE ADJUSTABLE SHELF T.O. SLAB 100' - 0" FIXED SHELF HANGER ROD BASE, AS SCHEDULED DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.5 7-11-2014 CASEWORK DETAILS 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.5 A1 LOBBY COUNTER SECTION 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.5 A2 LOBBY COUNTER SECTION 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.5 B1 WARDROBE CABINET SECTION GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 2. SEE SHEET A4.4 FOR PARTITION TYPES NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.5 A4 TYPICAL CASEWORK SECTION 240320 PACAB Work Session Laydown-Uplands T.O. STRUCTURE 113' - 0" 1/2" GYPSUM BOARD 1x4 WOOD FURRING AT 24" OC PLYWOOD ROOF SHEATHING, SEE STRUCT DWG 5/8" TYPE X GYPSUM BOARD GLU LAM BEAM, SEE STRUCT DWG 7/16" OSB SHEATHING 2x4 WOOD STUDS AT 24" OC 2x4 WOOD PLATE METAL CORNER BEAD 5/8" TYPE X GYPSUM BOARD 2X4 NAILER 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD METAL CORNER BEAD ACOUSTICAL CEILING PANELS METAL SYSPENSION SYSTEM RETURN AIR PLENUM T.O. STRUCTURE 113' - 0" 1/2" GYPSUM BOARD 1x4 WOOD FURRING AT 24" OC PLYWOOD ROOF SHEATHING, SEE STRUCT DWG 5/8" TYPE X GYPSUM BOARD GLU LAM BEAM WITH CLEAR TRANSPARENT FINISH, TYP, SEE STRUCT DWG 7/16" OSB SHEATHING 2x4 WOOD STUDS AT 24" OC 2x4 WOOD PLATE METAL CORNER BEAD 1" QUARTER ROUND WOOD TRIM WITH SEMI- TRANSPARENT STAIN FINISH AT EACH SIDE OF BEAM, TYPICAL OF ALL EXPOSED GLU LAM BEAMS 7/8" HAT CHANNELS AT 16" OC 3" CARRYING CHANNELS AT 48" OC 5/8" TYPE X GYPSUM BOARD 3" CHANNEL CURVED 1/2" GYPSUM BOARD - DRY BEND 11" 7/8" HAT CHANNEL AT 8" OC 2x8 AT EACH BCI, CUT CURVE TO 30'-0" RADIUS RETURN AIR PLENUM RETURN AIR PLENUM BCI, SEE STRUCTURAL DRAWINGS DEGREE METAL STRAP BRACE AT 45 DEGREE ANGLE BETWEEN EACH LIGHT FIXTURE 1/2" GYPSUM BOARD 7/8" HAT CHANNEL AT 16" OC METAL CORNER BEAD 1/2" GYPSUM BOARD METAL CORNER BEAD 1/2" GYPSUM BOARD 7/8" HAT CHANNEL AT 16" OC 5/8" TYPE X GYPSUM BOARD 1/2" GYPSUM BOARD ACOUSTICAL CEILING PANELS METAL SYSPENSION SYSTEM 2x4 WOOD STUDS AT 24" OC 7/16" OSB SHEATHING 1/2" GYPSUM WALL BOARD 3" CARRYING CHANNEL AT 24" OC 11" LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS STRIP LIGHT FIXTURES, OVERLAP 6", SEE ELECTRICAL DRAWINGS LINE OF BOTTOM OF RETURN AIR DUCT, SEE MECHANCIAL DRAWINGS 5"9" 3" CARRYING CHANNELS 3" CARRYING CHANNELS 5/8" TYPE X GYPSUM BOARD 5/8" TYPE X GYPSUM BOARD 1/2" GYPSUM WALL BOARD 7/8" HAT CHANNELS 9"5" METAL CORNER BEAD 3" CHANNEL DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.6 7-11-2014 CEILING DETAILS 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.6 A1 CEILING TRANSITION DETAIL 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.6 A2 CEILING TRANSITION DETAIL 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.6 C1 CONFERENCE ROOM CEILING DETAIL 1 1/2" = 1'-0" (22x34); 3/4" = 1'-0" (11x17)A4.6 A3 RESTROOM CEILING DETAIL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC WALL PANEL COLOR, TYP 1" 3/8" 1" STAINLESS STEEL NEOPRENE WASHERED FASTENER, SEE STRUCTURAL DRAWINGS, BLACK SOLID PHENOLIC EXTERIOR WALL PANEL TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 GRID PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC WALL PANEL COLOR, TYP SOLID PHENOLIC EXTERIOR WALL PANEL PREFINISHED BLACK ALUMINUM DRIP FLASHING, CONTINUOUS AT HORIZONTAL PANEL JOINT GRID PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING, TYP WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC WALL PANEL COLOR, TYP STAINLESS STEEL NEOPRENE WASHERED FASTENER, SEE STRUCTURAL DRAWINGS, TYP SOLID PHENOLIC EXTERIOR WALL PANEL, TYP TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 1" PREFINISHED BLACK ALUMINUM INSIDE CORNER CLOSURE FLASHING GRID GRID PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC WALL PANEL COLOR CENTERED BETWEEN PANEL JOINTS, TYP STAINLESS STEEL NEOPRENE WASHERED FASTENER, SEE STRUCTURAL DRAWINGS, BLACK SOLID PHENOLIC EXTERIOR WALL PANEL TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 GRID PREFINISHED BLACK ALUMINUM SUB-FRAMING WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC SOFFIT PANEL COLOR, TYP 1" 3/8" 1" STAINLESS STEEL NEOPRENE WASHERED FASTENER, SEE STRUCTURAL DRAWINGS, BLACK SOLID PHENOLIC EXTERIOR SOFFIT PANEL 2x6 WOOD JOIST, SEE STRUCTURAL DRAWINGS PLYWOOD SHEATHING, SEE STRUCTURAL DRAWINGS 3" 1" GRID GRID GRID 1" PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING, TYP WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC WALL PANEL COLOR, TYP STAINLESS STEEL NEOPRENE WASHERED FASTENER, SEE STRUCTURAL DRAWINGS, TYP SOLID PHENOLIC EXTERIOR WALL PANEL, TYP TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 PREFINISHED BLACK ALUMINUM INSIDE CORNER CLOSURE FLASHING CURVED EXTERIOR WALL ASSEMBLY, SEE A2/A4.2 PREFINISHED BLACK ALUMINUM SUB-FRAMING WEATHER BARRIER STAINLESS STEEL NEOPRENE WASHERED FASTENER, COLOR TO MATCH PHENOLIC SOFFIT PANEL COLOR, TYP STAINLESS STEEL NEOPRENE WASHERED FASTENER, SEE STRUCTURAL DRAWINGS, BLACK SOLID PHENOLIC EXTERIOR SOFFIT PANEL 2x6 WOOD JOIST, SEE STRUCTURAL DRAWINGS PLYWOOD SHEATHING, SEE STRUCTURAL DRAWINGS PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING FASTENER, SEE STRUCTURAL DRAWINGS, ALIGN WITH PHENOLIC PANEL FASTENERS AT INTERMEDIATE VERTICAL SUPPORT SOLID PHENOLIC EXTERIOR WALL PANEL TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 8 2' - 0" FASTENER, SEE STRUCTURAL DRAWINGS, ALIGN WITH FASTENERS IN VERTICAL ALUMINUM SUB- FRAMING AT VERTICAL JOINT PREFINISHED BLACK VERTICAL ALUMINUM SUB-FRAMING ALUMINUM SIDERAIL ALUMINUM BRACKET ALUMINUM WRUNG DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.7 7-11-2014 PHENOLIC PANEL DETAILS 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.7 A1 TYPICAL VERTICAL JOINT PHENOLIC WALL PANEL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.7 A2 TYPICAL HORIZONTAL JOINT 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.7 A3 TYPICAL OUTSIDE CORNER PHENOLIC WALL PANEL PHENOLIC WALL PANEL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.7 B1 VERTICAL INTERMEDIATE SUPPORT 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.7 C1 PANEL TYPICAL JOINT PHENOLIC WALL PANEL TYPICAL 3" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.7 C3 CURVED PHENOLIC WALL PANEL INSIDE CORNER 3" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.7 C2 INTERMEDIATE SUPPORT PHENOLIC SOFFIT PANEL TYPICALPHENOLIC SOFFIT 3" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.7 B2 ROOF ACCESS LADDER ATTACHMENT DETAIL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION PHENOLIC WALL PANEL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.7 A4 TYPICAL INSIDE CORNER 240320 PACAB Work Session Laydown-Uplands 1/2" 1'-0" EPDM ROOF MEMBRANE, CONTINUOUS UP BACK SIDE OF PARAPET, OVER TOP OF PARAPET AND EXTEND 6" DOWN FRONT OF PARAPET GASKETED FASTENER AT 24" OC CONTINUOUS PT WOOD PLATE SHIMMED TO SLOPE WITH 1/4" DIAMETER GALVANIZED SCREWS AT 24" OC STAGGERED R-21 BATT INSULATION IN PARAPET FRAMING CAVITY, SEE STRUCTURAL DRAWINGS FOR PARAPET FRAMING DETAILS R-21 BATT INSULATION IN ROOF FRAMING CAVITY, SEE STRUCTURAL DRAWINGS FOR FRAMING DETAILS WALL VAPOR RETARDER, SEAL TO EACH SIDE OF ROOF FRAMING MEMBER AND TO PLYWOOD ROOF SHEATHING TYP ROOF ASSEMBLY, SEE A1/A4.2 ROOF VAPOR RETARDER, SEAL TO PLYWOOD ROOF SHEATHING PREFINISHED ALUMINUM PARAPET COPING CONTINUOUS COPING CLIP WEATHER BARRIER, EXTEND UNDER EPDM MEMBRANE SOLID PHENOLIC EXTERIOR WALL PANEL ON 1" ALUMINUM SUB- FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING, EXTEND TO TOP OF WALL BEHIND PARAPET COPING TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 PREFINISHED BLACK ALUMINUM DRIP FLASHING AT HORIZONTAL PANEL JOINT OSB SHEATHING, SEE STRUCTURAL DRAWINGS TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 SOLID PHENOLIC EXTERIOR WALL PANELS ON 2" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING PREFINISHED BLACK ALUMINUM PERFORATED BASE CLOSURE PREFINISHED BLACK ALUMINUM PERFORATED TOP CLOSURE PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1/2" OVER PHENOLIC PANEL BELOW, COLOR TO MATCH PHENOLIC WALL PANEL ACCENT BAND COLOR #2 PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1/2" OVER PHENOLIC PANEL BELOW, COLOR TO MATCH PHENOLIC WALL PANEL ACCENT BAND COLOR #3 SOLID PHENOLIC EXTERIOR WALL PANELS ON 2 1/2" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING SOLID PHENOLIC EXTERIOR WALL PANELS ON 1" ALUMINUM SUB-FRAMING, SEE STRUCT DWG FOR FASTENERS TO SHEATHING PREFINISHED BLACK ALUMINUM PERFORATED BASE CLOSURE TYP EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL BASE, AS SCHEDULED WEATHER BARRIER, WRAP OVER ALUM ZEE FLASHING PREFINISHED BLACK ALUMINUM ZEE FLASHING, EXTEND OVER TOP EDGE OF PROTECTION BOARD PROTECTION BOARD RIGID PERIMETER INSULATION SS FASTENER AT 8" OC PT WOOD NAILER RIGID PERIMETER INSULATION PT WOOD PLATE, SEE STRUCTRUAL DRAWINGS CONCRETE SLAB ON GRADE, SEE STRUCTRUAL DRAWINGS SLAB VAPOR RETARDER 2" SAND DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.8 7-11-2014 WALL DETAILS 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.8 B1 ROOF PARAPET DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.8 A1 ACCENT BAND DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.8 A2 WALL BASE DETAIL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands C A1 A4.9 IN RETURN AIR PLENUM, WRAP JOIST WITH GYPSUM WALL BOARD HYDRONIC BASEBOARD, SEE MECHANICAL DRAWINGS ROOF DRAIN, SEE MECHANICAL DRAWINGS PHENOLIC SOFFIT PANELS UNDER 1" ALUMINUM SUB-FRAMING UNDER WEATHER BARRIER UNDER 1/2" PLYWOOD SHEATHING UNDER 2X6 JOISTS, SEE STRUCT DRAWINGS, WITH RIGID INSULATION IN JOIST CAVITY UNDER VAPOR RETARDER UNDER 1/2" GYPSUM BOARD TYP ROOF ASSEMBLY, SEE A1/A4.2 PREFINISHED ALUMINUM PARAPET COPING TYPICAL EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 CONTINUOUS OPENING FOR FULL LENGTH OF INSULATED CHASE, WRAP OPENING WITH 1/2" GYPSUM BOARD CEILING, AS SCHEDULED RETURN AIR PLENUM SOLID PHENOLIC EXTERIOR WALL PANELS OVER ALUMINUM SUB-FRAMING OVER WEATHER BARRIER OVER OSB WALL SHEATHING, SEE STRUCT DWG, OVER WOOD STUDS, SEE STRUCT DWG, WITH R-21 BATT INSULATION IN STUD CAVITY OVER JOIST RIM BOARDS OVER WALL VAPOR RETARDER OVER 1/2" GYPSUM WALL BOARD A4.8 B1 SIM, OPP RIGID INSULATION HEADER, SEE STRUCT DWG 1/2" GYPSUM BOARD UNDER PLYWOOD ROOF SHEATHING 6 C1 A4.9 IN RETURN AIR PLENUM, WRAP EACH JOIST WITH GYPSUM WALL BOARD ROOF DRAIN, SEE MECHANICAL DRAWINGS PHENOLIC SOFFIT PANELS UNDER 1" ALUMINUM SUB-FRAMING UNDER WEATHER BARRIER UNDER 1/2" PLYWOOD SHEATHING UNDER 2x6 JOISTS, SEE STRUCT DRAWINGS, WITH RIGID INSULATION IN JOIST CAVITY UNDER VAPOR RETARDER UNDER 1/2" GYPSUM BOARD TYP ROOF ASSEMBLY, SEE A1/A4.2 TYPICAL EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 CONTINUOUS OPENING IN WALL BEYOND FOR FULL LENGTH OF INSULATED CHASE, WRAP OPENING WITH 1/2" GYPSUM BOARD OVERFLOW ROOF DRAIN, SEE MECHANICAL DRAWINGS RETURN AIR PLENUM 1/2" PLYWOOD SHEATHING OVER 2x8 WOOD STUDS AT 24" OC WITH 2 LAYERS R-15 BATT INSULATION IN STUD CAVITY OVER WOOD JOISTS OVER VAPOR RETARDER OVER 1/2" GYPSUM BOARD A4.8 B1 SIM, OPP RTU, SEE MECHANICAL DRAWINGS 1/4" NEOPRENE GASKET CONTINUOUS AROUND PERIMETER OF CURB GALVANIZED METAL FLASHING WITH DRIP EDGE 1 1/2" RIGID ROOF INSULATION GALVANIZED METAL CURB PER MANUFACTURER FASTENER PER MANUFACTURER PT 2x4 WOOD NAILER EPDM MEMBRANE, CONTINUE UP CURB 1/2" PT PLYWOOD CANT STRIP TYP ROOF ASSEMBLY, SEE A1/A4.2 WOOD CURB, SEE STRUCTURAL DRAWINGS GLU LAM BEAM, SEE STRUCTURAL DRAWINGS ROOF VAPOR RETARDER, CONTINUE INSIDE CURB 6" RIGID ROOF INSULATION, CONTINUE INSIDE CURB 1/4" / 12" MINIMUM 1/4" / 12" MINIMUM 1' - 0"1' - 0" 2' - 0" A2 A4.9 T.O. STRUCTURE 113' - 0" 2' - 0" PIPE INSULATION, SEE MECHANICAL DRAWINGS UNDER DECK DRAIN BODY CLAMP CONTINUOUS ROOF VAPOR RETARDER CLAMP ROOF MEMBRANE INTO DRAIN CLAMPING RING ROOF DRAIN, SEE MECHANICAL DRAWINGS OVERFLOW ROOF DRAIN, SEE MECHANICAL DRAWINGS ROOF STRUCTURE, SEE STRUCTURAL DRAWINGS PLYWOOD ROOF SHEATHING, SEE STRUCTURAL DRAWINGS EPDM ROOF MEMBRANE 1/2" COVER BOARD BASE LAYER OF ROOF INSULATION T.O. STRUCTURE 113' - 0" SEAL FLASHING TO ROOF MEMBRANE PER MANUFACTURER'S RECOMMENDATION PIPE / CONDUIT AS INDICATED, SEE MECHANICAL AND ELECTRICAL DRAWINGS MASTIC OR SEALANT STAINLESS STEEL CLAMP PIPE INSULATION, SEE MECHANICAL DRAWINGS PREMOLDED PIPE FLASHING DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A4.9 7-11-2014 ROOF DETAILS 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.9 C1 INSULATED ROOF DRAIN CHASE AT ENTRY DECK 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.9 A1 INSULATED ROOF DRAIN CHASE AT ENTRY DECK 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A4.9 B3 RTU CURB DETAIL 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.9 A4 TYP ROOF DRAIN PLAN ROOF DRAIN, SEE MECHANICAL DRAWINGS OVERFLOW ROOF DRAIN, SEE MECHANICAL DRAWINGS 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.9 A2 TYP ROOF DRAIN DETAIL 1" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A4.9 B2 TYP PIPE PENETRATION DETAIL NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" D 3' - 6"1' - 0"42" SS HORIZONTAL GRAB BAR B TOILET SEAT COVER DISPENSER TOILET TISSUE DISPENSER WALL BASE, AS SCHEDULED 3' - 4" 1' - 3" 18" SS VERTICAL GRAB BAR 36" SS HORIZONTAL GRAB BAR ACCESSIBLE WATER CLOSET, SEE MECH DWG PAPER TOWEL DISPENSER, OFCI URINAL, SEE MECH DWG 24"x42" MIRROR WITH SS FRAME SOAP DISPENSER, OFCI ACCESSIBLE LAVATORY, SEE MECH DWG, INSULATE DRAIN AND HOT WATER SUPPLY LINE C 1' - 6" 1' - 0"2' - 0" WALL BASE, AS SCHEDULED TOILET COMPARTMENT A ALUMINUM WINDOW SYSTEM HORIZONTAL LOUVER BLINDS T.O. SLAB 100' - 0" BWALL BASE, AS SCHEDULED ALUMINUM WINDOW SYSTEM FLAT SCREEN MONITOR WITH WALL MOUNT BRACKET, OFCI, SEE ELECTRICAL DRAWINGS, PROVIDE BLOCKING T.O. SLAB 100' - 0" D ALUMINUM WINDOW SYSTEM BASE, AS SCHEDULED HORIZONTAL LOUVER BLINDS 3' - 0"2' - 0"1' - 6"1' - 6"1' - 6"3' - 0"1' - 0" 3' - 0"2' - 0"3' - 0"1' - 6"3' - 0"1' - 0"3' - 0" UNDERCOUNTER REFRIGERATOR (NIC) C UPPER CABINETS SOLID SURFACE COUNTERTOP AND BACKSPLASH BASE CABINETS PULL-OUT WASTE CONTAINER BASE CABINET WARDROBE CABINET A4 A4.5 B1 A4.5 WALL BASE, AS SCHEDULED SINK, SEE MECH DWG SCRIBE SCRIBE SCRIBE FIXED SHELF HANGER ROD ADJUSTABLE SHELF, TYP ADJUSTABLE SHELF, TYP A TOILET COMPARTMENT 8"3' - 0" 56" MIN DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.0 7-11-2014 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.0 B1 CONFERENCE ROOM 108 INTERIOR ELEVATIONS GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.0 A1 MEN'S RESTROOM 106 INTERIOR ELEVATIONS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands ALUMINUM WINDOW SYSTEM WALL BASE, AS SCHEDULED HORIZONTAL LOUVER BLINDS BA WALL BASE, AS SCHEDULED B 1' - 6" URINAL, SEE MECH DWG 2' - 0"1' - 0" C SHOWER BASE AND ENCLOSURE, SEE MECH DWG SOAP DISPENSER, OFCI WALL BASE, AS SCHEDULED 24"x42" MIRROR WITH SS FRAME PAPER TOWEL DISPENSER, OFCI T.O. SLAB 100' - 0" D WASHER AND DRYER POINT OF CONNECTION, SEE MECHANICAL AND ELECTRICAL DRAWINGS ACCESSIBLE LAVATORY, SEE MECH DWG, INSULATE DRAIN AND HOT WATER SUPPLY LINE WALL BASE, AS SCHEDULED A TOILET SEAT COVER DISPENSER 18" SS VERTICAL GRAB BAR 42" SS HORIZONTAL GRAB BAR 36" SS HORIZONTAL GRAB BAR TOILET TISSUE DISPENSER ACCESSIBLE WATER CLOSET, SEE MECH DWGSANITARY NAPKIN DISPOSAL WALL BASE, AS SCHEDULED 3' - 4" 3' - 6"1' - 0" T.O. SLAB 100' - 0" CLOSET ROD SHELF, TYP CLOSET ROD DRAWER, 3 EACH, TYP VERTICAL SUPPORT, TYP 1' - 6"2' - 0"1' - 0" WALL MOUNTED CLOSET ORGANIZER SYSTEM A T.O. SLAB 100' - 0" PAPER TOWEL DISPENSER, OFCI 24"x42" MIRROR WITH SS FRAME ACCESSIBLE LAVATORY, SEE MECH DWG, INSULATE DRAIN AND HOT WATER SUPPLY LINE WALL BASE, AS SCHEDULED 2' - 0"1' - 0" 1' - 3" 1' - 6" 42" SS HORIZONTAL GRAB BAR TOILET SEAT COVER DISPENSER TOILET TISSUE DISPENSER WALL BASE, AS SCHEDULED 18" SS VERTICAL GRAB BAR ACCESSIBLE WATER CLOSET, SEE MECH DWG 3' - 6"1' - 0" 3' - 4" 36" SS HORIZONTAL GRAB BAR SOAP DISPENSER, OFCI SANITARY NAPKIN DISPOSAL DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.1 7-11-2014 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.1 A1 HARBOR MASTER OFFICE 110 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.1 C1 UNISEX RESTROOM 123 INTERIOR ELEVATIONS HARBOR MASTER CLOSET 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.1 A4 INTERIOR ELEVATION GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.1 B1 WOMEN'S RESTROOM 105 INTERIOR ELEVATIONS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands 3' - 0"1' - 0"2' - 0" 1' - 6"1' - 6"3' - 0"3' - 0" A BASE CABINETS UPPER CABINETS PULL-OUT WASTE CONTAINER BASE CABINET POINT OF CONNECTION FOR COFFEE MAKER, SEE MECHANICAL AND ELECTRICAL DRAWINGS POINT OF CONNECTION FOR REFRIGERATOR, SEE MECHANICAL AND ELECTRICAL DRAWINGS A4 A4.5 WALL BASE, AS SCHEDULED ADJUSTABLE SHELF, TYP ADJUSTABLE SHELF, TYP T.O. SLAB 100' - 0" B ANGLED CORNER UPPER CABINET L-SHAPED CORNER BASE CABINET SOLID SURFACE COUNTERTOP AND BACKSPLASH BASE CABINETS UPPER CABINETS WALL BASE, AS SCHEDULED ALUMINUM WINDOW SYSTEM 2' - 9"2' - 0"1' - 0"2' - 0" 2' - 0"1' - 0"2' - 0"1' - 0"3' - 0"2' - 0"1' - 3" HORIZONTAL LOUVER BLINDS A4 A4.5 SINK WITH OFCI GARBAGE DISPOSAL, SEE MECH AND ELECT DRAWINGS ADJUSTABLE SHELF, TYP ADJUSTABLE SHELF, TYP SHELF WITH MOP AND BROOM HOLDERS FLOOR SINK, SEE MECH DWG WALL BASE, AS SCHEDULED T.O. SLAB 100' - 0" WALL BASE, AS SCHEDULED T.O. SLAB 100' - 0" ADA DOOR ACTUATOR, ROUGH-IN ONLY, SEE ELECTRICAL DRAWINGS CARD READER, OFCI, SEE ELECTRICAL DRAWINGS 8'x4' BULLETIN BOARD CASE RELOCATED FROM EXISTING BUILDING, OFCI, PROVIDE BLOCKING A WALL BASE, AS SCHEDULED B CABINET UNIT HEATER, SEE MECHANICAL DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.2 7-11-2014 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.2 A1 MULTI-PURPOSE BREAK ROOM 116 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.2 C1 JANITOR 107 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.2 C2 ARCTIC ENTRY 101 INTERIOR ELEVATIONS GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" FUTURE FLAT SCREEN MONITOR WITH WALL MOUNT BRACKET, ROUGH IN ONLY SEE ELECTRICAL DRAWINGS, PROVIDE BLOCKING ADA DOOR ACTUATOR, ROUGH-IN ONLY, SEE ELECTRICAL DRAWINGS 8'x4' BULLETIN BOARD CASE RELOCATED FROM EXISTING BUILDING, OFCI, PROVIDE BLOCKING A WALL BASE, AS SCHEDULED A1 A4.5 BASE CABINET WITH LOCKING DOORS B SOLID SURFACE COUNTERTOP WALL BASE, AS SCHEDULED ADJUSTABLE SHELF A2 A4.5 T.O. SLAB 100' - 0" A2 A4.5 C SOLID SURFACE COUNTERTOP WALL BASE, AS SCHEDULED SOLID SURFACE COUNTERTOP A1 A4.5 T.O. SLAB 100' - 0" A2 A4.5 SOLID SURFACE COUNTERTOP VERTICAL SUPPORT, TYP QUARTER CIRCLE ADJUSTABLE SHELF WALL BASE, AS SCHEDULED A1 A4.5 A ADJUSTABLE SHELF DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.3 7-11-2014 INTERIOR ELEVATION 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.3 A1 LOBBY 103 INTERIOR ELEVATIONS GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.3 C3 ADMIN HALL 104 INTERIOR ELEVATIONS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands B F T.O. SLAB 100' - 0" A WALL BASE, AS SCHEDULED HORIZONTAL LOUVER BLINDS HOLLOW METAL RELITE F HORIZONTAL LOUVER BLINDS ALUMINUM WINDOW SYSTEM A FIRE EXTINGUISHER WITH WALL MOUNT BRACKET UTILITY SINK, SEE MECH DRAWINGS WALL MOUNTED HARDWARE BIN STORAGE, OFCI, PROVIDE BLOCKING WALL BASE, AS SCHEDULED T.O. SLAB 100' - 0" B ALUMINUM WINDOW SYSTEM PAINT STORAGE CABINET, OFCI, PROVIDE BLOCKING POWER TOOL CABINET, OFCI, PROVIDE BLOCKING FLOOR MOUNTED AIR COMPRESSOR WITH OVERHEAD LINES, OFCI, SEE MECH AND ELECT DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.4 7-11-2014 INTERIOR ELEVATION 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.4 A1 DEPUTY HARBOR MASTER OFFICE 115 GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 2. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES. 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.4 B1 STORAGE/SHOP 123 INTERIOR ELEVATIONS NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands METAL LOCKER, TYP CONTINUOUS ZEE BASE LOCKER BENCH A T.O. SLAB 100' - 0" METAL LOCKER, TYP METAL FILLER PANEL TO MATCH LOCKERS CONTINUOUS ZEE BASE FIRE EXTINGUISHER CABINET B WALL BASE, AS SCHEDULED T.O. SLAB 100' - 0" METAL LOCKER, TYP METAL FILLER PANEL TO MATCH LOCKERS CONTINUOUS ZEE BASE C WALL BASE, AS SCHEDULED D DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.5 7-11-2014 INTERIOR ELEVATION 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.5 A1 LOCKER ROOM 121 INTERIOR ELEVATIONS GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands T.O. SLAB 100' - 0" A1 A4.5 SOLID SURFACE COUNTERTOP VERTICAL SUPPORT QUARTER CIRCLE ADJUSTABLE SHELF BASE CABINET B WALL BASE, AS SCHEDULED VERTICAL SUPPORT ADJUSTABLE SHELF EQ EQ A2 A4.5 WOOD TRIM, SEE B4/A4.3VENTED SOLID SURFACE SILL, SEE A3/A4.3 A ALUMINUM WINDOW SYSTEM HORIZONTAL LOUVER BLINDS T.O. SLAB 100' - 0" G ALUMINUM RELITE SYSTEM HORIZONTAL LOUVER BLINDS SOLID SURFACE COUNTERTOP WALL BASE, AS SCHEDULED B SOLID SURFACE SILLWOOD TRIM, SEE B4/A4.3 VENTED SOLID SURFACE SILL, SEE A3/A4.3 A SOLID SURFACE PARTITION, SEE B3/A4.3 ALUMINUM WINDOW SYSTEM HORIZONTAL LOUVER BLINDS SOLID SURFACE COUNTERTOP 2 1/2" x 2 1/2" x 1/4" STEEL ANGLE COUNTERTOP BRACKET @ 48" OC, PAINT TO MATCH WALL PAINT, TYP2" x 2" x 1/8" STEEL ANGLE EACH SIDE, PAINT TO MATCH WALL PAINT DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A5.6 7-11-2014 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.6 A1 ADMIN OPEN OFFICE 112 INTERIOR ELEVATIONS 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17)A5.6 C1 OPERATIONS 114 INTERIOR ELEVATIONS GENERAL NOTES: 1. THE INDICATED ELEVATION DATUM'S ON THE ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. SEE THE CIVIL DRAWINGS FOR THE FINAL FINISHED FLOOR ELEVATION. 2. SEE SHEET A6.1 FOR WINDOW/RELITE TYPES NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands ALUM ALUMINUM FF FACTORY FINISH FRP FIBERGLASS REINFORCED PLASTIC HM HOLLOW METAL NA NOT APPLICABLE P&P PRIMED AND PAINTED SCWD SOLID CORE WOOD STL STEEL TB-ALUM THERMAL BREAK ALUMINUM DOOR SCHEDULE LEGEND 1 FINISH FLOOR 32 6" 2 1/2"2 1/2" 4 MIN 9" ROOM-IDENTIFICATION SIGN, TYP LOCATION AT LATCH SIDE OF DOOR FINISH FLOOR 5 EQ EQ 2" SCHEDULE SEE DOOR 2" 1 FINISH FLOOR 1' - 2"1' - 2" 5' - 8" 3' - 4" 2"2" 2 1' - 2"1' - 2" 5' - 8" 3' - 4" 2"2" 3 GLASS TYPE GL-4 GLASS TYPE GL-2 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.0 7-11-2014 DOOR SCHEDULE, DOOR AND FRAME TYPES DOOR SCHEDULE DOOR NUMBER FIRE RATING DOOR GLASS FRAME DETAILS HARDWARE SET NUMBER REMARKS SIZE TYPE INSULATED MATERIAL FINISH TYPE SIZE (W x H) TYPE INSULATED MATERIAL FINISH HEAD JAMB THRESH OLDWIDTH HEIGHT THICKNESS 101-1 NONE 3' - 0" 7' - 0" 3 No TB-ALUM FF GL-5 VARIES 2 No TB-ALUM FF C1/A6.3 B1/A6.3 A1/A6.3 1 101-2 NONE 3' - 0" 7' - 0" 3 No ALUM FF GL-2 VARIES 3 No ALUM FF C2/A6.3 B2/A6.3 A2/A6.3 2 103-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 3 104-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 Yes FRP FF NA NA 1 Yes FRP FF C3/A6.3 B3/A6.3 AND A3/A6.6 A3/A6.3 16 105-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 4 106-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 4 107-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 18 108-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 6 109-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 7 110-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 8 110-2 NONE 5' - 0" 7' - 0" 1 3/4" 5 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 17 111-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 5 114-1 NONE 3' - 6" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" NA No NA NA 9 POCKET DOOR 115-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 8 116-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 Yes FRP FF GL-5 24" x 36" 1 Yes FRP FF C3/A6.3 B3/A6.3 A3/A6.3 16 117-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 10 118-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 11 119-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 No SCWD CLEAR FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 11 119-2 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 8 120-1 NONE 4' - 0" 7' - 0" 1 3/4" 1 Yes FRP FF NA NA 1 Yes FRP FF C3/A6.3 B3/A6.3 A4/A6.3 12 122-1 NONE 3' - 0" 7' - 0" 1 3/4" 1 No SCWD CLEAR FF NA NA 1 No HM P&P C4/A6.3 B4/A6.3 A4/A6.3 14 123-1 NONE 3' - 0" 7' - 0" 1 3/4" 2 Yes FRP FF GL-5 24" x 36" 1 Yes FRP FF C3/A6.3 B3/A6.3 A3/A6.3 16 123-2 NONE 10' - 0" 8' - 0" 2" 4 Yes STL FF GL-7 25" x 13" NA No NA NA C1/A6.4 B1/A6.4 A1/A6.4 15 SECTIONAL OVERHEAD DOOR 123-3 NONE 3' - 0" 7' - 0" 1 3/4" 2 Yes FRP FF GL-2 24" x 36" 1 No HM P&P C4/A6.3 B4/A6.3 A2/A6.6 13 GENERAL NOTES: 1. SEE SPECIFICATION SECTION "GLAZING" FOR GLASS TYPES. 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17) DOOR TYPES 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17) FRAME TYPES NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR GLASS TYPE GL-3 ALUMINUM FRAME HEAD DETAIL: C1 / A6.5 JAMB DETAIL: B1 / A6.5 SILL DETAIL: A1 / A6.5 GLASS TYPE GL-3 GLASS TYPE GL-3 GLASS TYPE GL-3 A 16' - 0" EQ 1 4' - 0"4' - 0"EQ 1 GLASS TYPE GL-4 ALUMINUM FRAME HEAD DETAIL: C1 / A6.5 JAMB DETAIL: B1 / A6.5 SILL DETAIL: A1 / A6.5 GLASS TYPE GL-3 GLASS TYPE GL-3 B 12' - 0" EQ 2 4' - 0"EQ 2 FINISH FLOOR GLASS TYPE GL-3 ALUMINUM FRAME HEAD DETAIL: C1 / A6.5 JAMB DETAIL: B1 / A6.5 SILL DETAIL: A1 / A6.5 GLASS TYPE GL-1 HOLLOW METAL FRAME HEAD DETAIL: C3 / A6.5 JAMB DETAIL: B3 / A6.5 SILL DETAIL: A3 / A6.5 EQ 3 EQ 34' - 0" 6' - 0" GLASS TYPE GL-1 HEAD DETAIL: C2 / A6.5 JAMB DETAIL: B2 / A6.5 SILL DETAIL: A2 / A6.5 GLASS TYPE GL-3 CIRCULAR WINDOW GLASS TYPE GL-2 ALUMINUM FRAME HEAD DETAIL: C3 / A6.4 RIGHT JAMB DETAIL: B3 / A6.4 LEFT JAMB DETAIL: A1/A6.6 SILL DETAIL: A3 / A6.4 5' - 0" ALUMINUM FRAME C GFE FINISH FLOOR GLASS TYPE GL-6 ALUMINUM FRAME HEAD DETAIL: C2 / A6.4 JAMB DETAIL: B2 / A6.4 SILL DETAIL: A3 / A4.3 D GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 GLASS TYPE GL-6 EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ FIELD VERIFY WIDTH, FACETED WINDOW SYSTEM WITH STEEL COLUMN AT EACH JAMB AND AT EACH VERTICAL MULLION TYP VERTICAL MULLION DETAIL: A2/A6.4 VERTICAL MULLION AT INTERIOR RELITE JAMB: A1/A6.6 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.1 7-11-2014 WINDOW/RELITE TYPES 1/2" = 1'-0" (22x34); 1/4" = 1'-0" (11x17) WINDOW / RELITE TYPES GENERAL NOTES: 1. SEE SPECIFICATION SECTION 088000 FOR GLASS TYPES. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands APPLIED FINISHES P1 SEMI-GLOSS PAINT P2 HIGH PERFORMANCE COATING S1 CONCRETE FLOOR SEALER S2 TRANSPARENT FINISH FF FACTORY FINISH FLOORS F1 CARPET TILE F2 RUBBER FLOOR TILE F3 VINYL PLANK FLOORING F4 STATIC-DISSIPATIVE RUBBER TILE F5 EXPOSED CONCRETE BASE B1 RUBBER BASE WALLS W1 GYPSUM WALL BOARD W2 MOISTURE RESISTANT GYPSUM WALL BOARD CEILINGS C1 5/8" TYPE X GYPSUM BOARD C2 2'x4' ACOUSTICAL CEILING TILE C3 2'x2' ACOUSTICAL CEILING TILE C4 5/8" TYPE X GYPSUM BOARD AND EXPOSED GLU LAM BEAMS FINISH SCHEDULE LEGEND DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.2 7-11-2014 FINISH SCHEDULE FINISH SCHEDULE ROOM NUMBER ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING REMARKS WALL WALL WALL WALL 101 ARCTIC ENTRY F3 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 9' - 0" 102 ENTRY HALL F3 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C4 P1/S2 12' - 11" 103 LOBBY F3 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C4 P1/S2 12' - 11" 104 ADMIN HALL F3 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 9' - 0" 105 WOMEN'S R.R. F3 FF B1 FF W2 P2 W2 P2 W2 P2 W2 P2 C1 P1 9' - 0" 106 MEN'S R.R. F3 FF B1 FF W2 P2 W2 P2 W2 P2 W2 P2 C1 P1 9' - 0" 107 JANITOR F5 S1 B1 FF W2 P2 W2 P2 W2 P2 W2 P2 C1 P1 9' - 0" 108 CONFERENCE ROOM F1 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C1, C3 P1, FF 0" COFFERED CEILING HEIGHTS: VARIES AT CENTER, 9'-6" AT PERIMETER 109 ELECTRICAL/IT ROOM F4 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C1 P1 11' - 6" 110 HARBOR MASTER OFFICE F3 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C3 FF 9' - 6" 111 ADMIN STORAGE F1 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C1 P1 9' - 0" 112 ADMIN OPEN OFFICE F1, F3 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C4 P1/S2 0" FLOOR FINISH VARIES (SEE A1/A2.4), CEILING HEIGHT VARIES (SEE A1/A2.1) 113 PRINTER ALCOVE F1 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C4 P1/S2 12' - 11" 114 OPERATIONS F2 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C4 P1/S2 12' - 11" 115 DEPUTY HARBOR MASTER OFFICE F2 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 9' - 6" 116 MULTI-PURPOSE BREAK ROOM F2 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2, C4 FF, P1/S2 0" C2 CEILING HEIGHT: 9'-0", C4 CEILING HEIGHT: 12' 11" 117 STORAGE F1 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 9' - 0" 118 PRIVATE HALL F2 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 9' - 0" 119 MEETING ROOM F1 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 9' - 0" 120 MECHANICAL ROOM F5 S1 B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C1 P1 11' - 6" 121 LOCKER ROOM F2 FF B1 FF W1 P1 W1 P1 W1 P1 W1 P1 C2 FF 8' - 6" 122 UNISEX RESTROOM F2 FF B1 FF W2 P2 W2 P2 W2 P2 W2 P2 C1 P1 9' - 0" 123 STORAGE/SHOP F5 S1 B1 FF W2 P2 W2 P2 W2 P2 W2 P2 C1 P1 11' - 6" GENERAL NOTES: 1. ALL COLORS SHALL BE SELECTED BY ARCHITECT UNLESS INDICATED OTHERWISE. 2. WALLS INDICATED AS BEING PAINTED IN ROOMS THAT RECEIVE ACOUSTICAL CEILING TILE, ARE TO BE PAINTED APPROXIMATELY 4" ABOVE CEILING HEIGHT. 3. SEE PARTITION TYPES ON SHEET A4.4 FOR THICKNESS OF GYPSUM WALL BOARD. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands RIGID WALL INSULATION HEADER, SEE STRUCT DWG GLASS AS SCHEDULED, SEE DOOR SCHEDULE ANNODIZED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1" OVER DOOR FRAME, EXTEND 6" UNDER WEATHER BARRIER SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER, WRAP OVER ALUM FLASHING OSB WALL SHEATHING, SEE STRUCT DWG BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD HEADER WEATHER BARRIER FLASHING AT JAMB PREFINISHED BLACK PERFORATED ALUM CLOSURE FLASHING METAL CORNER BEAD SEALANT ALUMINUM ENTRANCE SYSTEM 1/2" GYPSUM WALL BOARD J-METAL ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE GLASS AS SCHEDULED, SEE DOOR SCHEDULE GLASS AS SCHEDULED, SEE DOOR SCHEDULE JAMB STUDS, SEE STRUCT DWG SEALANT ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE SOLID PHENOLIC EXTERIOR WALL PANEL WEATHER BARRIER, WRAP UNDER ALUM FLASHING BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD STUDS WEATHER BARRIER FLASHING AT JAMB 1/2" GYPSUM WALL BOARD ALUMINUM SUB-FRAMING ANNODIZED ALUMINUM FLASHING, LAP 3/4" OVER ALUMINUM FRAME METAL CORNER BEAD J-METAL ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS THERMAL BREAK DOOR THRESHOLD GLASS AS SCHEDULED, SEE DOOR SCHEDULE EXPANSION JOINT, SEE STRUCTURAL DRAWINGS HEADER, SEE STRUCT DWG GLASS AS SCHEDULED, SEE DOOR SCHEDULE PARTITION TYPE 1, SEE SHEET A4.4 BACKER ROD AND SEALANT ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE 1/2" GYPSUM WALL BOARD J-METAL ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE GLASS AS SCHEDULED, SEE DOOR SCHEDULE GLASS AS SCHEDULED, SEE DOOR SCHEDULE ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE JAMB STUDS, SEE STRUCT DWG PARTITION TYPE 1, SEE SHEET A4.4 BACKER ROD AND SEALANT 1/2" GYPSUM WALL BOARD J-METAL ALUMINUM ENTRANCE SYSTEM, SEE DOOR SCHEDULE CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS GLASS AS SCHEDULED, SEE DOOR SCHEDULE DOOR THRESHOLD PARTITION, SEE SHEET A4.4 HM FRAME, SEE DOOR SCHEDULE DOOR, SEE DOOR SCHEDULE . CONTRACTOR VERIFY 1/2"1/2" CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS DOOR THRESHOLD VINYL DOOR SHOE DOOR, SEE DOOR SCHEDULE PARTITION, SEE SHEET A4.4 HM FRAME, SEE DOOR SCHEDULE DOOR, SEE DOOR SCHEDULE. CONTRACTOR VERIFY 1/2"1/2" PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1" OVER DOOR FRAME, EXTEND 6" UNDER WEATHER BARRIER, COLOR TO MATCH PHENOLIC PANEL COLOR #2 DOOR, SEE DOOR SCHEDULE FRP FRAME, SEE DOOR SCHEDULE RIGID WALL INSULATION HEADER, SEE STRUCT DWG SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER, WRAP OVER ALUM FLASHING OSB WALL SHEATHING, SEE STRUCT DWG BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD HEADER WEATHER BARRIER FLASHING AT JAMB PREFINISHED BLACK PERFORATED ALUM CLOSURE FLASHING METAL CORNER BEAD SEALANT 1/2" GYPSUM WALL BOARD J-METAL PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 3/4" OVER DOOR FRAME, EXTEND 6" UNDER WEATHER BARRIER, COLOR TO MATCH PHENOLIC PANEL COLOR #2 DOOR, SEE DOOR SCHEDULE FRP FRAME, SEE DOOR SCHEDULE JAMB STUDS, SEE STRUCT DWG SEALANT SOLID PHENOLIC EXTERIOR WALL PANEL WEATHER BARRIER, WRAP UNDER ALUM FLASHING BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD STUDS WEATHER BARRIER FLASHING AT JAMB 1/2" GYPSUM WALL BOARD ALUMINUM SUB-FRAMING METAL CORNER BEAD J-METAL CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS THERMAL BREAK DOOR THRESHOLD DOOR, SEE DOOR SCHEDULE DOOR SWEEP EXPANSION JOINT, SEE STRUCTURAL DRAWINGS DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.3 7-11-2014 DOOR DETAILS 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 C1 DOOR 101-1 HEAD DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 B1 DOOR 101-1 JAMB DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 A1 DOOR 101-1 THRESHOLD DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 C2 DOOR 101-2 HEAD 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 B2 DOOR 101-2 JAMB 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 A2 DOOR 101-2 THRESHOLD GENERAL NOTES: 1. SEE PARTITION TYPES ON SHEET A4.4 FOR HOLLOW METAL FRAME THROAT DIMENSIONS. 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 C4 DOOR FRAME HEAD 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 A4 DOOR FRAME THRESHOLD 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 B4 METAL DOOR JAMB INTERIOR HOLLOW METAL INTERIOR HOLLOW INTERIOR HOLLOW METAL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 C3 FRAME HEAD EXTERIOR FRP DOOR 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 B3 DOOR FRAME JAMB EXTERIOR FRP 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.3 A3 FRAME THRESHOLD EXTERIOR FRP DOOR NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands SECTIONAL OVERHEAD DOOR DOOR TRACK PREFINISHED ALUMINUM JAMB FLASHING, COLOR TO MATCH PHENOLIC WALL PANEL COLOR #2, WRAP ALL THREE SIDES WALL VAPOR RETARDER, SEAL TO WOOD STUDS EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WEATHER BARRIER FLASHING AT JAMB, WRAP ALL THREE SIDES ALUMINUM SUB-FRAMING SOLID PHENOLIC EXTERIOR WALL PANEL JAMB STUDS, SEE STRUCT DWG WEATHER BARRIER, WRAP UNDER JAMB FLASHING SEALANT WEATHER STRIPPING SECTIONAL OVERHEAD DOOR SOLID PHENOLIC EXTERIOR WALL PANEL BEYOND CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS EXPANSION JOINT, SEE STRUCTURAL DRAWINGS ALUMINUM SUB-FRAMING BEYOND PREFINISHED ALUMINUM JAMB FLASHING BEYOND, COLOR TO MATCH PHENOLIC WALL PANEL COLOR #2 SECTIONAL OVERHEAD DOOR SOLID PHENOLIC EXTERIOR WALL PANEL HEADER, SEE STRUCT DWG WALL VAPOR RETARDER, SEAL TO WOOD HEADER EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 ALUMINUM SUB-FRAMING PREFINISHED ALUMINUM FLASHING, COLOR TO MATCH PHENOLIC WALL PANEL COLOR #2, WRAP ALL THREE SIDES OVERHEAD DOOR TRACK WEATHER STRIPPING RIGID WALL INSULATION PRFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, COLOR TO MATCH PHENOLIC WALL PANEL COLOR #2 WEATHER BARRIER, WRAP OVER ALUM FLASHING OSB WALL SHEATHING, SEE STRUCT DWG WEATHER BARRIER FLASHING AT JAMB, WRAP ALL THREE SIDES PREFINISHED BLACK PERFORATED ALUM CLOSURE FLASHING SEALANT EXTERIOR ANODIZED ALUMINUM BRAKE METAL FILLER, SEE DETAIL C1 ON SHEET A6.6 INTERIOR ANODIZED ALUMINUM BRAKE METAL FILLER, SEE DETAIL C1 ON SHEET A6.6 ALUMINUM WINDOW SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 SEALANT, TYP STEEL COLUMN, SEE STRUCTURAL DRAWINGS, WRAP COLUMN WITH SEPARATOR MATERIAL WOOD SHIM, TYP 171.79° SEALANT, TYP 3/4" RIGID WALL INSULATION SEALANT ALUMINUM RELITE SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 BACKER ROD AND SEALANT SOLID SURFACE SILL RELITE SILL FRAMING 1/2" PARTITION, SEE SHEET A4.4 GLASS AS SCHEDULED, SEE SHEET A6.1 BACKER ROD AND SEALANT METAL CORNER BEAD SEALANT ALUMINUM RELITE SYSTEM 1/2" GYPSUM WALL BOARD J-METAL METAL CORNER BEAD HEADER, SEE STRUCT DWG PARTITION, SEE SHEET A4.4 SEALANT ALUMINUM RELITE SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 BACKER ROD AND SEALANT 1/2" GYPSUM WALL BOARD METAL CORNER BEAD J-METAL JAMB STUDS, SEE STRUCT DRAWINGS PARTITION, SEE SHEET A4.4 STEEL COLUMN, SEE STRUCTURAL DRAWINGS, WRAP COLUMN WITH SEPARATOR MATERIAL SEALANT ALUMINUM WINDOW SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 CURVED SOLID PHENOLIC EXTERIOR WALL PANEL WEATHER BARRIER, WRAP UNDER ALUM FLASHING PLYWOOD SHIM CURVED EXTERIOR WALL ASSEMBLY, SEE A2/A4.2 WALL VAPOR RETARDER, SEAL TO STEEL COLUMN WEATHER BARRIER FLASHING AT JAMB 1/2" GYPSUM WALL BOARD ALUMINUM SUB-FRAMING METAL CORNER BEAD J-METAL ANNODIZED ALUMINUM FLASHING, WRAP JAMB BACKER ROD AND SEALANT RIGID WALL INSULATION, THICKNESS VARIES HEADER, SEE STRUCT DWG GLASS AS SCHEDULED, SEE SHEET A6.1 ANNODIZED ALUMINUM FLASHING WITH HEMMED DRIP EDGE SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER, WRAP OVER ALUM FLASHING OSB WALL SHEATHING, SEE STRUCT DWG BACKER ROD AND SEALANT CURVED EXTERIOR WALL ASSEMBLY, SEE A2/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD HEADER WEATHER BARRIER FLASHING AT JAMB INSECT SCREENMETAL CORNER BEAD SEALANT ALUMINUM WINDOW SYSTEM 1/2" GYPSUM WALL BOARD J-METAL ANNODIZED ALUMINUM FLASHING, WRAP HEAD VARIES DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.4 7-11-2014 DOOR AND WINDOW DETAILS 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 B1 SECTIONAL OVERHEAD DOOR JAMB 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 A1 SECTIONAL OVERHEAD DOOR THRESHOLD 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 C1 SECTIONAL OVERHEAD DOOR HEAD 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 A2 TYP CURVED WINDOW VERTICAL MULLION DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 A3 TYP ALUM RELITE SILL DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 C3 TYP ALUM RELITE HEAD DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 B3 TYP ALUM RELITE JAMB DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 B2 TYP CURVED WINDOW JAMB DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.4 C2 TYP CURVED WINDOW HEAD DETAIL 2 1 NO. DATE 1 6-10-2014 2 7-11-2014 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD WINDOW SILL FRAMING WINDOW SILL FRAMING SEALANT ALUMINUM WINDOW SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1/2" OVER PHENOLIC PANEL BELOW, COLOR TO MATCH PHENOLIC PANEL COLOR #1 SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER BACKER ROD AND SEALANT WEATHER BARRIER FLASHING AT JAMB, WRAP OVER WEATHER BARRIER SOLID SURFACE SILL 1/2" RIGID WALL INSULATION HEADER, SEE STRUCT DWG GLASS AS SCHEDULED, SEE SHEET A6.1 ALUMINUM WINDOW SYSTEM SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER, WRAP OVER ALUM FLASHING OSB WALL SHEATHING, SEE STRUCT DWG BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD HEADER WEATHER BARRIER FLASHING AT JAMB TWO LAYERS OF 1/4" FLEXIBLE GYPSUM WALL BOARD - WET BEND METAL CORNER BEAD SEALANT J-METAL CIRCULAR ANNODIZED ALUMINUM FLASHING WITH HEMMED EDGE, LAP 1/2" OVER PHENOLIC PANEL JAMB STUDS, SEE STRUCT DWG GLASS AS SCHEDULED, SEE SHEET A6.1 ALUMINUM WINDOW SYSTEM SOLID PHENOLIC EXTERIOR WALL PANEL WEATHER BARRIER, WRAP OVER ALUM FLASHING ABOVE MID-POINT OF WINDOW, WRAP UNDER ALUM FLASHING BELOW MID-POINT OF WINDOW BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1A4.2 WALL VAPOR RETARDER, SEAL TO WOOD STUDS WEATHER BARRIER FLASHING AT JAMB TWO LAYERS OF 1/4" FLEXIBLE GYPSUM WALL BOARD - WET BEND ALUMINUM SUB-FRAMING METAL CORNER BEAD SEALANT J-METAL CIRCULAR ANNODIZED ALUMINUM FLASHING WITH HEMMED EDGE, LAP 1/2" OVER PHENOLIC PANEL RIGID WALL INSULATION HEADER, SEE STRUCT DWG GLASS AS SCHEDULED, SEE SHEET A6.1 ANNODIZED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 1" OVER WINDOW FRAME SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER, WRAP OVER ALUM FLASHING OSB WALL SHEATHING, SEE STRUCT DWG BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD HEADER WEATHER BARRIER FLASHING AT JAMB PREFINISHED BLACK PERFORATED ALUM CLOSURE FLASHING METAL CORNER BEAD SEALANT ALUMINUM WINDOW SYSTEM 1/2" GYPSUM WALL BOARD J-METAL JAMB STUDS, SEE STRUCT DWG SEALANT ALUMINUM WINDOW SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 SOLID PHENOLIC EXTERIOR WALL PANEL WEATHER BARRIER, WRAP UNDER ALUM FLASHING BACKER ROD AND SEALANT EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD STUDS WEATHER BARRIER FLASHING AT JAMB 1/2" GYPSUM WALL BOARD ALUMINUM SUB-FRAMING ANNODIZED ALUMINUM FLASHING, LAP 3/4" OVER WINDOW FRAME METAL CORNER BEAD J-METAL EXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD WINDOW SILL FRAMING WINDOW SILL FRAMING SEALANT ALUMINUM WINDOW SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 CIRCULAR ANNODIZED ALUMINUM FLASHING WITH HEMMED EDGE, LAP 1/2" OVER PHENOLIC PANEL SOLID PHENOLIC EXTERIOR WALL PANEL ALUMINUM SUB-FRAMING WEATHER BARRIER BACKER ROD AND SEALANT WEATHER BARRIER FLASHING AT JAMB, WRAP OVER WEATHER BARRIER TWO LAYERS OF 1/4" FLEXIBLE GYPSUM WALL BOARD - WET BEND METAL CORNER BEAD J-METAL CONTRACTOR VERIFY HEADER, SEE STRUCT DWG PARTITION, SEE SHEET A4.4 HOLLOW METAL FRAME, SEE SHEET A6.1 GLAZING STOP GLASS AS SCHEDULED, SEE SHEET A6.1 1/2"1/2" CONTRACTOR VERIFY JAMB STUDS, SEE STRUCT DWG PARTITION, SEE SHEET A4.4 HOLLOW METAL FRAME, SEE SHEET A6.1 GLAZING STOP GLASS AS SCHEDULED, SEE SHEET A6.1 1/2"1/2" CONTRACTOR VERIFY WINDOW SILL FRAMING PARTITION, SEE SHEET A4.5 HOLLOW METAL FRAME, SEE SHEET A6.1 GLAZING STOP GLASS AS SCHEDULED, SEE SHEET A6.1 1/2"1/2" DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.5 7-11-2014 WINDOW AND RELITE DETAILS 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 A1 TYP WINDOW SILL DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 C2 CIRCULAR WINDOW HEAD DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 B2 CIRCULAR WINDOW JAMB DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 C1 TYP WINDOW HEAD DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 B1 TYP WINDOW JAMB DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 A2 CIRCULAR WINDOW SILL DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 C3 TYP HOLLOW METAL RELITE HEAD DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 B3 TYP HOLLOW METAL RELITE JAMB DETAIL 3" = 1'-0" (22x34); 1 1/2" = 1'-0" (11x17)A6.5 A3 TYP HOLLOW METAL RELITE SILL DETAIL GENERAL NOTES: 1. SEE PARTITION TYPES ON SHEET A4.4 FOR HOLLOW METAL FRAME THROAT DIMENSIONS. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands H 4.1 3/4" RIGID WALL INSULATIONALUMINUM WINDOW SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 STEEL COLUMN, SEE STRUCTURAL DRAWINGS, WRAP COLUMN WITH SEPARATOR MATERIAL WOOD SHIM, TYP SEALANT, TYP PREFINISHED ALUMINUM SILL FLASHING BELOW ALUMINUM RELITE SYSTEM GLASS AS SCHEDULED, SEE SHEET A6.1 VENTED SOLID SURFACE SILL BELOW, SEE A3/A4.3 VENTED SOLID SURFACE SILL BELOW, SEE A3/A4.3 SOLID SURFACE SILL BELOW ANODIZED ALUMINUM BRAKE METAL COVER EXTERIOR ANODIZED ALUMINUM BRAKE METAL FILLER, SEE DETAIL C1 ON SHEET A6.6 CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS DOOR THRESHOLD DOOR SWEEP DOOR, SEE DOOR SCHEDULE PREFINISHED ALUMINUM FLASHING WITH HEMMED DRIP EDGE, LAP 3/4" OVER DOOR FRAME, EXTEND 3" BEHIND PHENOLIC PANEL, COLOR TO MATCH PHENOLIC PANEL COLOR #2 DOOR, SEE DOOR SCHEDULE FRP FRAME, SEE DOOR SCHEDULE JAMB STUDS, SEE STRUCT DWG SEALANT SOLID PHENOLIC EXTERIOR WALL PANEL WEATHER BARRIER, WRAP UNDER ALUM FLASHING BACKER ROD AND SEALANTEXTERIOR WALL ASSEMBLY, SEE A1/A4.2 WALL VAPOR RETARDER, SEAL TO WOOD STUDS WEATHER BARRIER FLASHING AT JAMB, WRAP UNDER WEATHER BARRIER 1/2" GYPSUM WALL BOARD ALUMINUM SUB-FRAMING METAL CORNER BEAD J-METAL 2 C PARTITION, SEE SHEET A4.4 EXTERIOR ANODIZED ALUMINUM BRAKE METAL FILLER INTERIOR ANODIZED ALUMINUM BRAKE METAL FILLER 171.78° 171.79° ANODIZED ALUMINUM BRAKE METAL COVER 2" DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A PK BC, SY PK CONFORMED DRAWING SET 1325 7-11-2014 A6.6 7-11-2014 DOOR AND WINDOW DETAILS 3" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A6.6 A1 ALUM RELITE JAMB AT CURVED WINDOW 3" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A6.6 A2 DOOR FRAME THRESHOLD INTERIOR HOLLOW METAL 3" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A6.6 A3 EXTERIOR FRP DOOR FRAME JAMB 6" = 1'-0" (22x34); 1/2" = 1'-0" (11x17)A6.6 C1 CURVED WINDOW BRAKE METAL DETAILS 2 2 NO. DATE 2 7-11-2014 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S1.0 GENERAL NOTES GENERAL ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO REQUIREMENTS OF THE INTERNATIONAL CODE COUNCIL INTERNATIONAL BUILDING CODE (IBC) 2009 EDITION. WHERE EXPLICIT DETAILS ARE NOT SHOWN OR DESCRIBED, THE MINIMUM REQUIREMENTS OF THE ABOVE CODE SHALL APPLY. UNLESS OTHERWISE NOTED, ALL CODES, STANDARDS AND OTHER PUBLICATIONS CITED SHALL REFER TO THE LATEST EDITION. LOCATION THESE DRAWINGS ARE INTENDED FOR THE CONSTRUCTION OF (1) BUILDING LOCATED IN HOMER, ALASKA. DESIGN LOADS IN ADDITION TO DEAD LOADS, THE FOLLOWING LOADS WERE USED FOR DESIGN: OCCUPANCY CATEGORY: II ROOF: GROUND SNOW LOAD Pg=40 PSF FLAT-ROOF SNOW LOAD Pf=40 PSF SNOW EXPOSURE FACTOR Ce=1.0 SNOW LOAD IMPORT. FACTOR Is= 1.0 FLOOR LIVE LOAD: 100PSF CORRIDORS 60 PSF OFFICES WIND: BASIC WIND SPEED (3 SEC GUST)V=120 MPH EXPOSURE D EXP=1.47 WIND LOAD IMPORT. FACTOR Iw=1.0 METHOD 1 SIMPLIFIED PROCEDURE USED FOR DESIGN. SEE ROOF PLAN FOR COMP AND CLADDING WIND LOADS TO BE USED FOR DESIGN. OTHER LOADS SHALL BE PER ASCE 7-05. SEISMIC: SEISMIC LOAD IMPORT. FACTOR Ie=1.0 SPECT. RESPONSE ACCEL.Ss=148%, S1=56% SITE CLASS D. SPECTRAL RESPONSE COEFF.Sds=0.99 Sd1=0.56 SEISMIC DESIGN CATEGORY: D LATERAL LOADS ARE RESISTED BY, WOOD SHEAR WALLS AND PLYWOOD ROOF DIAPHRAGM. BUILDING SEISMIC BASE SHEAR V=33.7k SEISMIC RESPONSE COEFF,Cs=0.164 RESPONSE MODIFICATION FACTOR R=6 EQUIVALENT LATERAL FORCE PROCEDURE USED FOR DESIGN FUTURE CONSTRUCTION: BUILDING FOUNDATION AND FRAMING DESIGNED TO SUPPORT ADDITIONAL FUTURE STORY WITH SIMILAR FRAMING LAYOUT AND DESIGN LOADS. FOUNDATIONS INSITU SOILS ARE ASSUMED TO BE NON-FROST SUSCEPTABLE (NFS) GRAVEL. EXCAVATE EXISTING SOILS AS REQUIRED TO PLACE FOUNDATION AT ELEVATIONS LISTED ON PLANS. COMPACT SUBGRADE TO 95% OF MAX DRY DENSITY PRIOR TO PLACING FOOTINGS ON FILL. PLACE ALL INTERIOR AND EXTERIOR FOOTINGS ON COMPACTED NATURAL UNDISTURBED, NFS SOIL OR ON COMPACTED NON-FROST SUSCEPTIBLE TYPE III GRAVEL BACKFILL FREE OF ORGANIC MATTER AND DEBRIS. BACKFILLSHALL BE PLACED IN LIFTS NOT EXCEEDING 12 INCHES IN LOOSE THICKNESS AND COMPACTED TO 95% OF MAXIMUM DENSITY IN ACCORDANCE WITH ASTM SPECIFICATION D-1557. ALLOWABLE BEARING CAPACITY OF 3000 PSF WAS USED FOR DESIGN. FOUNDATION INSULATION FOUNDATION INSULATION SHALL BE 'DOW HIGHLOAD 40' EXTRUDED POLYSTYRENE INSULATION, 'BLUEBOARD' OR 'INSULFOAM' HIGH DENSITY EXPANDED POLYSTYRENE . WITH 40 PSI MIMIMUM COMPRESSIVE STRENGTH. SLABS ON GRADE EXCAVATE OR FILL REQUIRED TO PLACE SLAB AT ELEVATIONS INDICATED ON THE DRAWINGS. COMPACT THE EXISTING SOIL TO 95% OF MAXIMUM DENSITY AND BACKFILL WITH NON-FROST SUSCEPTIBLE GRAVEL AND COMPACT AS DESCRIBED ABOVE. PLACE REINFORCING STEEL AT MID-DEPTH OF SLAB AND SUPPORT AT 4'O/C MAXIMUM WITH WELL CURED CONCRETE BLOCKS OR APPROVED METAL CHAIRS. DO NOT SUPPORT ON STONES. PROVIDE SAWCUT CONTROL OR CONSTRUCTION JOINTS (C.J.) AT LOCATIONS SHOWN ON THE PLANS AND AT 12' O/C MAXIMUM. EXTERIOR SLABS: PROVIDE A MINIMUM OF 72 INCHES OF NON-FROST SUSCEPTIBLE GRAVEL BELOW SLAB CONFORMING TO THE GRADATION AND COMPACTION REQUIREMENTS DESCRIBED ABOVE FOR FOUNDATIONS. DRAINAGE: SLOPE ALL EXTERIOR SLABS ADJACENT TO BUILDINGS TO DRAIN AWAY FROM BUILDING PERIMETER AT 1/8" PER FOOT MINIMUM SLOPE. CONCRETE MIXING, SELECTION OF MATERIALS, AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE IBC, CHAPTER 19. AN AIR ENTRAINING AGENT SHALL BE USED IN ALL CONCRETE MIXES FOR CONCRETE WORK WHICH IS TO BE EXPOSED TO EARTH OR WEATHER. AIR ENTRAINMENT SHALL BE 5% +/- 1% BY VOLUME. ALL CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH (F'C) = 3000 P.S.I. EXCEPT CONCRETE GROUT FOR MASONRY WALLS WHICH SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH (F'c)= 2000 P.S.I. CONCRETE FOR INTERIOR AND EXTERIOR SLABS SHALL CONTAIN 0.1% BY VOLUME 'GENSIS FIBER' COLLATED FIBRILLATED POLYPROPYLENE FIBER PER CUBIC YARD OF CONCRETE. THE FIBER SHALL BE THOROUGHLY MIXED INTO THE CONCRETE IN TRANSIT TO THE SITE, IN ACCORDANCE WITH THE FIBER MANUFACTURER'S RECOMMENDATIONS. REINFORCING STEEL UNLESS NOTED OTHERWISE, ALL REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO IBC CHAPTER 19. REINFORCING BARS SHALL BE GRADE 60. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 DOUBLE ANNEALED IRON WIRE. REINFORCING IN FOOTINGS SHALL BE SUPPORTED ON WELL CURED CONCRETE BLOCKING OR APPROVED METAL CHAIRS. REINFORCING BARS SHALL BE SPLICED BY A LAP OF AT LEAST 40 BAR DIAMETERS. A MINIMUM LAP FOR ALL BARS SHALL BE 24". CONCRETE COVER OVER REINFORCING SHALL BE 3" FOR CONCRETE CAST AGAINST EARTH. CONCRETE COVER FOR FORMED CONCRETE THAT WILL BE EXPOSED TO WEATHER OR EARTH SHALL BE 2" MINIMUM FOR #6 THROUGH #18 BARS AND 1 1/2" MINIMUM FOR #5 BARS AND SMALLER, INCLUDING WELDED WIRE FABRIC (WWF). OTHER REINFORCEMENT SHALL HAVE A MINIMUM COVERAGE OF NOT LESS THAN 3/4". ANCHOR BOLTS AND CONCRETE EXPANSION ANCHORS ANCHOR BOLTS, THREADED RODS AND CONCRETE EXPANSION ANCHORS SHALL CONFORM TO ASTM A 307. CONCRETE EXPANSION ANCHORS (KB) SHALL BE "HILTI KWIK BOLT TZ" CONCRETE EXPANSION ANCHORS OR STRUCTURAL EQUIVALENT, INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ANCHOR BOLTS SHALL BE PROVIDED WITH HEX HEAD NUTS AND 3"x3"x1/4" STEEL PLATE WASHERS. WHERE BOLTS OR RODS ARE USED WITH CEDAR SILL PLATES, BOLTS, NUTS AND WASHERS SHALL BE GALVANIZED. ALL FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED OR SHALL BE STAINLESS STEEL. PROVIDE 5/8" X 10" ANCHOR BOLTS AT 48" O/C SPACING UNLESS NOTED OTHERWISE AND WITHIN 6" OF WALL OPENINGS AND BUILDING CORNERS. POWER FASTENERS POWER FASTENERS FOR CONNECTION TO CONCRETE, OR STEEL SHALL BE POWDER ACTUATED HILTI X-AL-H HEAVY DUTY DOME HEAD NAILS WITH 0.177 INCH SHANK DIAMETER. MINIMUM FASTENER EMBEDMENT SHALL BE 1 3/8". NAIL LENGTH SHALL BE AS REQUIRED TO ACHIEVE SPECIFIED MINIMUM PENETRATION INTO SUBSTRATE. FASTENERS SHALL BE HOT-DIPPED GALVANIZED AT EXTERIOR CONDITIONS. POWDER FASTENERS FOR CONNECTION INTO CONCRETE MASONRY UNITS SHALL BE POWDER ACTUATED HILTI X-C STANDARD NAILS WITH A MINIMUM SHANK DIAMETER OF 0.138". MINIMUM FASTENER EMBEDMENT SHALL BE 1". NAIL LENGTH SHALL BE AS REQUIRED TO ACHIEVE SPECIFIED MINIMUM PENETRATION INTO SUBSTRATE. ADHESIVE ANCHORING SYSTEM THREADED ROD ANCHORS AND REINFORCING BAR DOWELS SHALL BE SET IN HILTI HIT RE-500SD ADHESIVE OR STRUCTURAL EQUIVALENT. ADHESIVE ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE ADHESIVE MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES. MINIMUM EMBEDMENT IN CONCRETE FOR ALL ANCHORS SHALL BE 31/2" UNLESS NOTED OTHERWISE. STRUCTURAL STEEL AND CONNECTORS STRUCTURAL STEEL SHALL CONFORM TO IBC CHAPTER 22, FOR ASTM SPECIFICATION A-36, FY = 36 K.S.I. EXCEPT WHERE NOTED OTHERWISE. STEEL TUBING (HSS) SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 K.S.I. DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE IBC CHAPTER 22, DIVISION IX, ALLOWABLE STRESS DESIGN. MACHINE BOLTS (MB) SHALL CONFORM TO ASTM A325 AND SHALL BE PROVIDED WITH STANDARD HEX HEAD NUTS CONFORMING TO ASTM A563, GRADE A AND HARDENED STEEL CIRCULAR WASHERS CONFORMING TO ASTM F436. ALL WELDING SHALL CONFORM TO AMERICAN WELDING SOCIETY D1.1. WELD ALL FAYING SURFACES WITH CONTINUOUS 3/16" FILLET WELD (MINIMUM) UNLESS OTHERWISE NOTED. ELECTRODES SHALL BE A.W.S. E-70. ANCHOR ALL COLUMNS WITH MINIMUM (4) 3/4" X 10" ANCHOR BOLTS UNLESS SHOWN OTHERWISE. PROVIDE ADEQUATE LATERAL BRACING FOR STRUCTURE DURING CONSTRUCTION. ALL WELDS SHALL BE MADE WITH A FILLER METAL CAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LB AT 0 DEG F. DEMAND CRITICAL WELDS SHALL USE FILLER METAL CAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LB AT -20 DEG F. STEEL FABRICATOR SHALL BE CERTIFIED BY AISC FOR FABRICATION OF STEEL BUILDING STRUCTURES. UPON COMPLETION OF WORK, FABRICATOR SHALL SUBMIT CERTIFICATION OF COMPLIANCE. NON-COMPOSITE STEEL FORM DECK: STEEL FORM DECKING SHALL BE 20 GAUGE, TYPE B G- 60 GALVANIZED STEEL DECKING WITH A MINIMUM YIELD STRENGTH (FY) = 38,000 PSI. FURNISH DECK IN 36" NOMINAL WIDTH. FASTEN TO SUBSTRATE AS SPECIFIED FOR NON-COMPOSITE STEEL FLOOR AND ROOF DECKING. CONCRETE FLOOR SLAB SHALL BE REINFORCED WITH 6" X 6" W1.4/W1.4 WELDED WIRE MESH THROUGHOUT. REINFORCING MESH SHALL BE SUPPORTED AT 4' O/C EACH WAY ON APPROVED METAL CHAIRS. WHERE DECKING IS SUPPORTED BY WOOD MEMBERS FASTEN DECK TO FRAMING WITH (2) #12 X 2" SELF TAPPING TRUSS HEAD SCREWS AT EACH FLUTE, 8" O/C AND FASTEN ADJOINING SHEETS WITH PUNCHLOK TOOL, BUTTON PUNCHES, OR 1 1/2" LONG TOP SEAM WELDS AT A MAXIMUM SPACING OF 36" O/C PER MANUFACTURERS RECOMMENDATIONS. RETAINING WALLS: USE ONLY FREE DRAINING NON-FROST SUSCEPTIBLE GRAVEL SOILS FOR BACKFILL AGAINST RETAINING WALLS. BACKFILL SHALL NOT BE PLACED AGAINST RETAINING WALLS UNTIL RETAINING WALL CONCRETE HAS ACHIEVED THE 28 DAY DESIGN STRENGTH F'C = 3000 PSI. BACKFILL SHALL NOT BE PLACED AGAINST RETAINING WALLS UNTIL FLOOR SLABS HAVE BEEN CAST AND ALLOWED TO CURE FOR AT LEAST 7 DAYS AND FLOOR SLAB CONCRETE HAS ACHIEVED AT LEAST 50% OF THE 28 DAY DESIGN STRENGTH. SPECIAL INSPECTION PROVIDE A SPECIAL INSPECTION PROGRAM IN ACCORDANCE WITH IBC CHAPTER 17. PROVIDE DOCUMENTATION OF SPECIAL INSPECTION TO ENGINEER OF RECORD AND BUILDING OFFICIAL. STEEL 1.) PERIODIC INSPECTION OF HIGH STRENGTH BOLT MARKINGS TO CONFORM WITH SPECIFIED BOLTS. 2.) VERIFICATION OF BOLT MANUFACTURER'S CERTIFICATE OF COMPLIANCE 3.) PERIODIC INSPECTION OF SNUG TIGHT BOLTED CONNECTIONS. 4.) PERIODIC INSPECTION OF PRETENSIONED AND SLIP CRITICAL BOLTED CONN. 5.) VERIFICATION OF STRUCTURAL STEEL AND METAL DECK IDENTIFICATION MARKINGS, GRADES AND MANUFACTURERS CERTIFIED TEST REPORTS. 6.) VERIFICATION OF WELD FILLER MATERIALS IDENTIFICATION MARKINGS AND MANUFACTURERS CERTIFICATE OF COMPLIANCE 7.) CONTINUOUS INSPECTION OF COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS, MULTIPASS FILLET WELDS, FILLET WELDS GREATER THAN 5/16", AND PLUG/SLOT WELDS. 8.) PERIODIC INSPECTION OF SINGLE PASS FILLET WELDS <= 5/16". 9.) PERIODIC INSPECTION OF FLOOR AND ROOF DECK WELDS. CONCRETE 1.) INSPECTION OF REINFORCING STEEL SIZE AND PLACEMENT PRIOR TO PLACING OF CONCRETE. 2.) INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING PLACED 3.) TESTING FOR EACH TRUCKLOAD OF CONCRETE MATERIALS INCLUDING: SLUMP, ENTRAINED AIR CONTENT, TEMPERATURE, AND STRENGTH. 4.) CONTINUOUS INSPECTION OF CAST-IN-PLACE BOLTS TO BE INSTALLED IN CONCRETE. 5.) PERIODIC INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE. 6.) PERIODIC VERIFY USE OF REQUIRED DESIGN MIX. 7.) PERIODIC INSPECTION OF MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. PRESSURE TREATED WOOD ALL WOOD INDICATED AS PRESSURE TREATED, (PT) SHALL BE PRESSURE TREATED (PT) IN ACCORDANCE THE AMERICAN WOOD PRESERVER'S ASSOCIATION (AWPA) STANDARD U1-02. THE PRESERVATIVE SHALL BE ALKALINE COPPER QUAT (ACQ). ALL WOOD SHALL BE TREATED TO A RETENTION OF 0.60 PCF AS REQUIRED FOR 'GROUND CONTACT' ALL PRESSURE TREATED WOOD SHALL BE APPROPRIATELY MARKED ATTESTING TO COMPLIANCE WITH THESE REQUIREMENTS. LUMBER SHALL BE DRIED AFTER TREATMENT TO A MOISTURE CONTENT OF 19% OR LESS. ALL BOLTS, NAILS AND SIMPSON CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE TYPE 304 OR TYPE 316 STAINLESS STEEL. FIELD TREAT ALL CUTS AND HOLES. PROVIDE 2 COATS OF EFFECTIVE SEALER. ALL GLULAM BEAMS INDICATED AS PRESSURE TREATED SHALL BE TREATED WITH ACQ PRESERVATIVE PER AWPA U1-02. GLUED LAMINATED STRUCTURAL UNITS MATERIALS, MANUFACTURE, AND QUALITY CONTROL OF GLUED LAMINATED STRUCTURAL UNITS (GLULAM) SHALL CONFORM TO IBC CHAPTER 23 WITH ALLOWABLE STRESSES AS DEFINED IN AMERICAN FOREST & PAPER ASSOCIATION 'NATIONAL DESIGN SPECIFICATION 2001 SUPPLEMENT', TABLE 5A, AND SHALL BE DOUGLAS FIR, COMBINATION 24F-V8, DF/DF. GLUE LAMINATED STRUCTURAL UNITS SHALL BE GRADE MARKED BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, AITC. ORIENTATED STRAND BOARD (OSB) ALL ORIENTATED STRAND BOARD SHALL CONFORM TO IBC STANDARD 23-3 AND SHALL BE AMERICAN PLYWOOD ASSOCIATION GRADE TRADE MARKED. ALL PANELS SHALL BE NOMINAL 4'x8' PANELS. UTILIZE FULL SHEETS WHEREVER POSSIBLE. LAY STRENGTH AXIS OF ROOF AND FLOOR SHEATHING PANELS PERPENDICULAR TO SUPPORTS AND WITH PANEL CONTINUOUS OVER THREE OR MORE SPANS. STAGGER END JOINTS OF SUCCESSIVE COURSES 4'. OSB WALL SHEATHING: SHALL BE 7/16" PANELS WITH EXTERIOR GLUE. UNLESS NOTED OTHERWISE ON THE DRAWINGS, WALL SHEATHING SHALL BE FASTENED TO FRAMING WITH 8D GALVANIZED NAILS 3" O/C ALONG PANEL EDGES AND 12" O/C ALONG INTERMEDIATE SUPPORTS. WALL SHEATHING SHALL BE BLOCKED AT ALL EDGES WITH NOMINAL 2" SOLID BLOCKING. MANUFACTURED WOOD JOISTS FABRICATED WOOD JOISTS SHALL BE OF THE SIZE INDICATED ON THE DRAWINGS AND AS MANUFACTURED BY BOISE CASCADE OR APPROVED EQUAL. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION, HANDLING AND ERECTION OF FLOOR JOISTS. PROVIDE WEB STIFFENERS PER MANUFACTURER'S RECOMMENDATIONS AND ON BOTH SIDES OF WEBS WHERE JOISTS ARE SUPPORTED BY JOIST HANGERS. PROVIDE BLOCKING PANELS AT SUPPORTS AND ENDS OF JOISTS. PROVIDE FULL THICKNESS BACKER PLATE BETWEEN DOUBLE JOISTS WHERE JOIST IS FRAMED PERPENDICULAR INTO A DOUBLE JOIST. PROVIDE SOLID RIM JOISTS AROUND FULL PERIMETER OF FLOOR SYSTEM. UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE LAMINATED VENEER LUMBER HEADERS, WITH DEPTH EQUAL TO JOIST DEPTH, AT ALL OPENINGS IN FLOOR AND ROOF SYSTEMS. UNLESS NOTED OTHERWISE, PROVIDE FACE MOUNT JOIST HANGERS WITH CAPACITY EQUAL TO THE FULL SHEAR CAPACITY OF THE JOIST AT ALL JOISTS WHERE JOIST IS NOT SUPPORTED BY DIRECT BEARING. SAWN LUMBER AND TIMBER LUMBER SHALL CONFORM TO THE CLASSIFICATION, DEFINITION, AND GRADING REQUIREMENTS OF IBC CHAPTER 23 WITH ALLOWABLE UNIT STRESSES AS GIVEN IN THE AMERICAN FOREST & PAPER ASSOCIATION 'NATIONAL DESIGN SPECIFICATION 2001 SUPPLEMENT', TABLE 4A. LUMBER SHALL BE GRADE MARKED BY THE WEST COAST LUMBER INSPECTION BUREAU /WESTERN WOOD PRODUCTS ASSOCIATION. ITEM SPECIES 4 X AND LARGER DOUGLAS FIR #2 BEARING WALL PLATES HEM FIR #2 BEARING WALL STUDS HEM FIR #2 ALL OTHER LUMBER HEM FIR #2 ALL LUMBER SHALL BE FASTENED IN CONFORMANCE WITH TABLE 2304.9.1 OF THE IBC, UNLESS NOTED OTHERWISE. FASTENERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. FASTEN ALL JOIST BLOCKING TO PLATES WITH (4) 16D MINIMUM AND FASTEN ALL WALL PLATES TO WOOD FLOORS WITH 16D AT 6" ON CENTER TYPICAL. DOUBLE TOP PLATES SHALL OVERLAP 10' - 0" MINIMUM AND SHALL BE SPLICED TOGETHER WITH 16D NAILS AT 6" ON CENTER MINIMUM UNLESS NOTED OTHERWISE. PROVIDE JOIST/BEAM HANGERS WITH LOAD CAPACITY EQUAL TO SUPPORTED MEMBER SHEAR LOAD CAPACITY FOR ALL MEMBERS NOT OTHERWISE PROVIDED WITH DIRECT BEARING SUPPORT. PROVIDE A MINIMUM OF (2) KING STUDS AND (2) CRIPPLE STUDS FOR ALL BEARING WALL HEADERS. PROVIDE A MINIMUM OF (1)KING STUD AND (1) CRIPPLE STUD AT NON-BEARING WALL HEADERS. PROVIDE SOLID BLOCKING SUPPORT FOR BEAMS AND HEADERS CONTINUOUS DOWN TO FOUNDATIONS. MINIMUM HEADER OVER OPENINGS IN BEARING WALLS SHALL BE 4X12 DF#1 UNLESS NOTED OTHERWISE. BOLT HEADS AND NUTS BEARING AGAINST WOOD TO BE PROVIDED WITH FLAT WASHERS. SOLID BLOCKING OF NOT LESS THAN 2" NOMINAL THICKNESS SHALL BE PROVIDED AT ENDS AND AT ALL SUPPORTS OF JOISTS AND RAFTERS, UNLESS SHOWN OTHERWISE. BEAM AND JOIST HANGERS SHALL HAVE A CAPACITY EQUAL TO THE SHEAR STRENGTH OF THE BEAM OR JOIST WHICH IT IS SUPPORTING, UNLESS NOTED OTHERWISE. ALL METAL FRAMING ANCHORS AND HANGERS SHOWN ON DRAWINGS SHALL BE "STRONG TIE CONNECTORS" AS MANUFACTURED BY SIMPSON COMPANY OR APPROVED EQUAL. ALL SIMPSON CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE TYPE 304 OR TYPE 316 STAINLESS STEEL. PLYWOOD ALL PLYWOOD SHALL CONFORM TO IBC STANDARD 2303.1.4 AND SHALL BE AMERICAN PLYWOOD ASSOCIATION GRADE TRADE MARKED. PLYWOOD SHALL BE GROUP I OR GROUP II DOUGLAS FIR. ALL PANELS SHALL BE NOMINAL 4' X 8' PANELS. UTILIZE FULL SHEETS WHEREVER POSSIBLE. LAY FACE GRAIN OF ROOF AND FLOOR SHEATHING PANELS PERPENDICULAR TO JOISTS AND TRUSSES AND WITH PANEL CONTINUOUS OVER THREE OR MORE SPANS. STAGGER END JOINTS OF SUCCESSIVE COURSES 4' - 0". WALL SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN PARALLEL TO STUDS, (LONG DIMENSION VERTICAL). ROOF SHEATHING: SHALL BE 1 1/8" THICK APA 48 oc SPAN RATED TONGUE AND GROOVE PLYWOOD UNDERLAYMENT WITH EXTERIOR GLUE. SHEATHING SHALL BE GLUED AND SCREWED TO SUPPORTS WITH 2 1/2" X #8 TYPE C COARSE THREAD GRIPPERS AT 6" O/C. FASTEN TO BLOCKING PANELS AND WALL PLATES AT 4" O/C WITH DESIGNATED FASTENERS. BREAK ROWS OF PANELS A MINIMUM OF 2' FROM ENDS OF JOISTS AT INTERIOR LOCATIONS. (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands A S3.1 A S3.2 17' - 7"2' - 9"9' - 10"4' - 7 3/4"10 3/4"14' - 8 1/2"5' - 5"18' - 2" 5 3/4" THICK x3' TALL CONC. 'QUAD-LOK' WALL W/ #4 REBAR @ 16" O/C, EACH WAY 16"Wx24"D MONO. CONC. FOOTING W/(2) #5 REBAR, TYP. 4" CONC. SLAB W/ W1.4xW1.4 6x6 WWM A S4.1 4" SLAB W/ W1.4xW1.4 6x6 WWM 4" SLAB W/ W1.4xW1.4 6x6 WWM D S4.1 24"Wx10"D CONC. FOOTING W/(3) #5 REBAR CONT. 6" THICK STEM WALL W/ #4 REBAR @ 18" O/C , EACH WAY 12"x12"x8" CONC. SUMP 12" THICK CONCRETE SLAB. (BELOW) 9' - 1 3/4" 5 1/4" 3 7/16" 9 1/4" 2 5 5 5 5 5 5 1 2 3 4.14 5 6 7 8 A B C D E F F.2 G H A A A B B A C C C C C D D B 9' - 9" B S3.1 B S3.2 R1 R2 R3 R4 R5 R6 R7 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 74' - 0" 18' - 2"35' - 6"20' - 4" 2 22 CONC. WALKWAY PER CIVIL S2.5 A 8' - 0"8' - 0" B S4.1 B S4.2 5 8' - 0" 3 3 G S4.1 I S4.1 5' - 0" D S4.3 CONCRETE DRIVEWAY PER CIVIL R0 R8 P17 P18 P19 P20 P21 P22 P23 P24 P25 7" EDGE OF FRAMING & FACE OF CONCRETE RADIUS= 29'-10 3/4" BOLLARD PER CIVIL, TYP. 12"DIA. PILASTER, TYP. 1' - 3 1/2"6 1/2" B PILASTER PER A/S4.3, TYP. @ OVERSLOPE FOOTINGS 6 5' - 3 1/2"2 S4.3 E -HOLDOWN (SEE FRAMING PLAN FOR TYPE & LOCATION) LEGEND H S4.1 C S4.2 B G S4.3 9 1/4" DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.1 FOUNDATION & OVERSLOPE PLAN SCALE: 3/16" = 1'-0" (22x34) A S2.1 FOUNDATION & OVERSLOPE FRAMING PLAN FOOTING SCHEDULE SYMBOL DIMENSIONS REBAR 2 24"x24"x12"#5 BARS @ 12" EACH WAY 3 36"x36"x12"#5 BARS @ 12" EACH WAY, T&B 5 60"x60"x16"#5 BARS @ 12" EACH WAY, T&B MONOLITHIC FOOTING SCHEDULE SYMBOL DIMENSIONS REBAR A 24"Wx12"D (3)#5 BARS B 16"Wx12"D (2)#5 BARS C 16"Wx24"D (4)#5 BARS D 6"Wx8"D (1)#5 BARS BUILDING COORDINATES SYMBOL DESCRIPTION NORTHING GRIDS P1 BUILDING CORNER GL:1/B EASTING N 34490.00 E 72022.19 PLAN NORTHTRUE NORTH P2 BUILDING CORNER GL:2/BN 34480.56 E 72037.71 BUILDING CORNER GL:2/CN 34470.27 E 72031.46 BUILDING CORNER GL:6/CN 34451.82 E 72061.78 BUILDING CORNER GL:6/AN 34468.94 E 72072.20 BUILDING CORNER GL:8/AN 34458.38 E 72089.57 BUILDING CORNER GL:8/GN 34401.35 E 72054.88 BUILDING CORNER GL:1/GN 34439.81 E 71991.66 RADIAL WORK POINT R=29'-10 3/4" GL:4.1/F.2N 34429.98 E 72031.55 COLUMN GL:R1N 34425.13 E 72002.34 COLUMN GL:R2N 34417.07 E 72004.91 COLUMN GL:R3N 34410.07 E 72009.64 COLUMN GL:R4N 34404.69 E 72016.16 COLUMN GL:R5N 34401.37 E 72023.94 COLUMN GL:R6N 34400.39 E 72032.34 COLUMN GL:R7N 34401.82 E 72040.67 CL CL CL CL CL CL CL CONCRETE EDGE GL:R0/GN 34433.60 E 72001.87 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 P24 P25 BEAM BEARING GL:R1/GN 34426.88 E 72012.91 BEAM BEARING GL:R2/GN 34423.58 E 72018.34 BEAM BEARING GL:R3/GN 34421.33 E 72022.03 BEAM BEARING GL:R4/GN 34419.44 E 72025.14 BEAM BEARING GL:R5/GN 34417.55 E 72028.24 BEAM BEARING GL:R6/GN 34415.31 E 72031.94 BEAM BEARING GL:R7/GN 34412.00 E 72037.37 CONCRETE EDGE GL:R8/GN 34405.29 E 72048.41 6 78"x78"x12"#7 BARS @ 12" EACH WAY, T&B (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 2 2 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands A S3.1 A S3.2 1 2 3 4.14 5 6 7 8 A B C D E F F.2 G H B S3.1 B S3.2 R1 R2 R3 R4 R5 R6 R7 LEGEND CONC. WALKWAY PER CIVIL B1 B3.5 B3.6B3.4 B3.3 B3.2 B3.1 B2.1 B2.2 B2.3 B2.4 B6.1 B2.5 B2.6 SLOPE FLOOR TO DRAIN. EVAPORATIVE TRENCH. RIM ELEV.= 99'-11"7' - 5" CONTROL JOINTS @ 16' O/C MAX, EACH WAY PER DETAIL C/S4.1 B6.2 B6.3 B6.4 B6.9 B6.8 B6.10 B6.11 B6.7 B6.6 B6.5 B6.14 B6.15 B6.13 B6.12 BX.X -BASEPLATE PER SHEET S4.4 B6.16 J S4.1 CONCRETE DRIVEWAY PER CIVIL R0 R8 SLOPE FLOOR TO DRAIN. FLOOR DRAIN PER MECH. RIM ELEV.=99'-11 3/4", TYP. 106ARCH'L ROOM- SLOPE FLOOR TO DRAIN. FLOOR DRAIN PER MECH. RIM ELEV.=99'-11 3/4", TYP. 105ARCH'L ROOM- SLOPE FLOOR TO DRAIN. FLOOR DRAIN PER MECH. RIM ELEV.=99'-11 3/4", TYP. 122ARCH'L ROOM- SLOPE FLOOR TO DRAIN. FLOOR DRAIN PER MECH. RIM ELEV.=99'-11 1/2", TYP. 120ARCH'L ROOM- SLOPE FLOOR TO DRAIN. FLOOR DRAIN PER MECH. RIM ELEV.=99'-11 1/2", TYP. 121ARCH'L ROOM- 123ARCH'L ROOM- EDGE OF CONCRETE, TYP. 2" RECESS IN SLAB LOCATE PER ARCH F S4.3 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.2 FOUNDATION FINISH PLAN SCALE: 3/16" = 1'-0" (22x34) A S2.2 FOUNDATION FINISH PLAN (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands A S3.1 A S3.2 SW4SW4 SW3SW3 SW2 SW4 SW4 SW2 D S5.1 S2.7 A 1 2 3 4.14 5 6 7 8 A B C D E F F.2 G H 5 1/8"x18" GLB 5 1/8"x18" GLB 5 1/8"x18" GLB 5 1/8"x18" GLB 5 1/8"x18" GLB 5 1/8"x18" GLB 3 1/8"x18" GLB 3 1/8"x18" GLB 3 1/8"x18" GLB 3 1/8"x18" GLB C S5.1 1 1/4"x18" VERSARIM @ PERIMETER, TYP. E E E E C A C A A A C F D A A A D A A A B S3.1 B S3.2 B S5.1 R1 R2 R3 R4 R5 R6 R7 3 1/8"x18" GLB 5 1/8"x18" GLB E S5.1 3 1/8"x18" GLB A S5.2 A A S5.1 R0 R8 18" BCI BLOCKING @ 24" O/C 18" BCI BLOCKING @ 24" O/C 18" BCI BLOCKING @ 24" O/C S2.6 A C S5.3 JOIST PER A/S5.2 A NOTE 2 NOTE 2 S2.7 B 5 1/8"x18" GLB 5 1/8"x18" GLB ROOF ACCESS LADDER PER ARCH'L. ATTACH PER DETAIL G/S5.3 G G G G G G G G G G G G G G G G DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.3 ROOF FRAMING PLAN SCALE: 3/16" = 1'-0" (22x34) A S2.3 ROOF FRAMING PLAN FIRST FLOOR SHEARWALL SCHEDULE SYMBOL SHEATHING FIELD ANCHOR BOLT SW1 7/16" OSB ONE SIDE 8D@12"10"x5/8" @ 48" O/C FASTENERS EDGE 8D@6" SW2 BOTTOM PLATE PT SINGLE 2x 7/16" OSB ONE SIDE 8D@12"8D@4"PT SINGLE 2x SW3 7/16" OSB ONE SIDE 8D@12"8D@4"PT DOUBLE 2x SW4 7/16" OSB ONE SIDE 8D@12"8D@3"PT DOUBLE 2x 10"x5/8" @ 48" O/C 10"x5/8" @ 48" O/C 10"x5/8" @ 32" O/C HEADER SCHEDULE SYMBOL DIMENSIONS POST A 4x10 (2) 2x8 JACK STUD (2) 2x8 KING STUD B 3 1/8"x12"(2) 2x8 JACK STUD (2) 2x8 KING STUD C 5 1/8"x15"(2) 2x8 JACK STUD (3) 2x8 KING STUD D 5 1/8"x18"(2) 2x8 JACK STUD (3) 2x8 KING STUD E 4x10 HSS4x4x1/4" -SHEAR WALL -BEARING WALL NOTE: 1). ALL INTERIOR BEARING WALLS SHALL CONSIST OF 2X6 STUDS @ 24" O/C AND STUDS SHALL ALIGN W/ JOISTS ABOVE. 2). PROVIDE CS16 STRAPS & BLOCKING AROUND WINDOW FRAMING PER DETAIL F/S5.3. F 5 1/8"x24"(2) 2x8 JACK STUD (3) 2x8 KING STUD G 2x8 HSS4x2x1/4" 1 1TYP. NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands 1 2 3 4.14 5 6 7 8 A B C D E F F.2 G H R1 R2 R3 R4 R5 R6 R7 LEGEND 8'x4' T&G PLYWOOD SHEET (STRENGTH AXIS SHOWN) PARTIAL T&G PLYWOOD SHEET (STRENGTH AXIS SHOWN) NOTE: 1). PLYWOOD LOCATIONS ARE APPROXIMATE. UTILIZE FULL SHEETS WHEN EVER POSSIBLE.TRANSVERSE SHEET EDGES SHALL ALIGN WITH THE CENTERLINE OF WALLS, JOISTS & GLULAM BEAMS. 2). DRAG STRUTS SHALL BE PLACED FLAT OVER ROOF SHEATHING. 3). FASTEN DRAG STRUTS TO ROOF SHEATHING W/ 2 1/2" #8 SCREWS @ 4" O/C, TYP. 4). SPLICE 2x8 DRAG STRUT W/ SIMPSON CMT12 STRAP W/ 38" END LENGTH. 5). SPLICE (2)2x12 DRAG STRUT W/(2) SIMPSON CMT12 STRAPS W/ 38" END LENGTH. SHEATHING DATUM R0 R8 NOTE: PROVIDE SPLINE PANEL EDGE REINFORCEMENT ALONG ALL UNSUPPORTED PANEL EDGE PER DETAIL B.S2.4 B S2.4 DRAG STRUT 2x8 DRAG STRUT 2x8 DRAG STRUT (2) 2x12 DRAG STRUT ATTACH DRAG STRUT OVER SHEARWALL W/4"x0.25" TIMBERLOK FASTENERS @ 6" O/C ATTACH DRAG SRUT OVER SHEARWALL W/4"x0.25" TIMBERLOK FASTENERS @ 2" O/C (STAGGERED) 1 1/8" PLYWOOD SHEATHING, TYP. 1/4"x2" PLYWOOD SPLINE, CONT. PANEL EDGE DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.4 ROOF SHEATHING PLAN SCALE: 3/16" = 1'-0" (22x34) A S2.4 ROOF SHEATHING PLAN SCALE: 6" = 1'-0" (22x34) B S2.4 PLYWOOD SPLINE PANEL EDGE NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION (NO REVISIONS ON THIS SHEET)1 240320 PACAB Work Session Laydown-Uplands A S3.2 E S4.2 2 3 4.14 5 6 7 G H R1 R2 R3 R4 R5 R6 R7 D S4.2 A S4.3 B S4.3 C S4.3 5 3/4" THICKx4' TALL CONC. 'QUAD-LOK' STEM WALL W/#4 REBAR @ 16" O/C, EACH WAY 24"Wx10"D CONC. FOOTING W/(3)#5 REBAR, CONT. E S4.1 1 1/2" TYPE B 20GA STEEL DECKING (SPAN DECKING E-W) R=29'-7 3/4"5" CONC. SLAB W/ W1.4xW1.4 6x6 WWM THROUGHOUT ALIGN EDGE OF CONC. SLAB W/ EDGE OF FRAMING R0 R8 EDGE OF FRAMING & FACE OF CONCRETE RADIUS= 29'-10 3/4" HOLD METAL DECKING BACK 3" FROM EDGE (R=29'-7 3/4") 2x10 TEMPORARY SHORING, TYP. -BEAM HANGER PER DETAIL A/S4.5 -BEAM HANGER PER DETAIL B/S4.5 LEGENDNOTE: 1). SPRAY POLYURETHANE FOAM INSULATION PER ARCH TO UNDERSIDE OF DECK. 2). APPLY 60 MIL THICK LAYER OF POLYUREA COATING TO UNDERSIDE OF INSULATION. A S5.6 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.5 ENLARGED FOUNDATION @ OVERSLOPE SCALE: 3/8" = 1'-0" (22x34) A S2.5 ENLARGED FOUNDATION @ OVERSLOPE PLAN NORTHTRUE NORTH (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands A S3.2 HSS4"x2"x1/4"HSS4"x2"x1/4" 3 1/8"x18" GLULAM 3 1/8"x18" GLULAM 5 1/8"x18" GLULAM 5 1/8"x18" GLULAM 3 1/8"x18" GLULAM 3 1/8"x18" GLULAM 3 1/8"x18" GLULAM 5 1/8"x18" GLULAM 5 1/8"x18" GLULAM 2 3 4.14 5 6 7 F F.2 G H C S5.1 -BEAM HANGER PER SCHEDULE LEGEND: R1 R2 R3 R4 R5 R6 R7 R0 R8 3 1/8"x18" GLULAM C S5.2 B S5.2 5 1/8"x18" GLULAM 5 1/8"x18" GLULAM -HSS COLUMN 1 3 2 4 5 6 7 8 3 2 4 567 8 9 10 11 911 12 19 19 15 14 16 18 17 E S5.3 1 3/4"x18" VERSALAM S5.3 D OUTER 2x4 STUDS. PROVIDE STUDS @ ARCH'L PANEL Z SUPPORTS INNER 2x4 STUDS @ 8" O/C. ALIGN W/ EDGE OF DRYWALL SHEATHING, TYP. OUTER 2x4 STUDS. PROVIDE STUDS @ OSB SHEATHING EDGES A S5.6 A S5.6 TYP. 13 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.6 ENLARGED ROOF FRAMING @ OVERSLOPE SCALE: 3/8" = 1'-0" (22x34) A S2.6 ENLARGED ROOF FRAMING @ OVERSLOPE BEAM HANGER SCHEDULE MARK TYPE DETAILS 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 3 1/4" GLB HANGER A/S5.4 5 1/4" GLB HANGER B/S5.4 5 1/4" GLB HANGER B/S5.4 5 1/4" GLB HANGER B/S5.4 5 1/4" GLB HANGER B/S5.4 SKEWED DOUBLE BEAM HANGER A/S5.5 DOUBLE BEAM HANGER B/S5.5 MULTI BEAM COLUMN CAP C/S5.5 SIMPSON CCO 5 1/4 COLUMN CAP N/A SIMPSON ECCO 5 1/4 COLUMN CAP N/A SIMPSON CCO COLUMN CAP W/5 1/8" MAIN MEMBER & 5 1/8" SIDE MEMBER N/A 5 1/4" GLB HANGER B/S5.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 19 1 1 1 1 1TYP. NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands (FUTURE ELEVATOR) (FUTURE STAIR WELL) 5 6 7 D E F F.2 3 1/8"x18" GLULAM 3 1/8"x18" GLULAM F S5.2 G S5.2 B S5.3 1 3/4x18" VERSALAM 1 3/4x18" VERSALAM 3 D DIM PER ARCH'L DIM PER MFR DIM PER MFR DIM PER MFR DIM PER MFR PROVIDE 4x8 LEDGER @ OUTLINE OF RTU BLOCK AROUND MECH. OPENING W/ 1 3/4"x18" VERSALAM, TYP. 3 1/8"x18" GLULAM 3 1/8"x18" GLULAM C S2.7 4x8 LEDGER OVER ROOF SHEATHING RTU CURB PER MFR. 4x8 @ PERIMETER 1 1/8" ROOF SHEATHING INSULATION PER ARCH'L ATTACH RTU TO 4x8 W/STAINLESS STEEL #10 SELF-DRILLING SCREWS @ 16" O/C SIMPSON HGA10 CLIP @ EACH JOIST BELOW, TYP. DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S2.7 ENLARGED ROOF FRAMING PLANS SCALE: 1/2" = 1'-0" (22x34) A S2.7 ENLARGED FRAMING PLAN AT FUTURE ELEVATOR/STAIR SCALE: 1" = 1'-0" (22x34) B S2.7 ENLARGED FRAMING PLAN AT RTU SCALE: 3" = 1'-0" (22x34) C S2.7 RTU CURB SUPPORT (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR 100' - 0" ROOF 113' - 0" A S3.2 18" BCI JOIST PER PLAN GLULAM BEAM PER PLAN 18" BCI JOIST PER PLAN 4" EXTERIOR SLAB ON GRADE PER PLAN 4" CONC. SLAB ON GRADE W/ W1.4xW1.4 6x6 WWM 1 2 3 4.14 5 6 7 8 T.O. PARAPET 114' - 9" (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAIN SCREEN PANEL EDGES PER A/S5.3 2x6 STUDS @ 24" O/C, ALIGN WITH JOISTS ABOVE 1 1/8" T&G PLYWOOD SHEATHING S5.1 D B S3.2 S5.2 G S4.1 A S4.1 D 5' - 0" S5.1 A S4.3 D S5.1 A (3) 2x8 TOP PLATES PT 2x8 BOTTOM PLATES PER SHEARWALL SCH. PT 2x6 BOTTOM PLATES PER SHEARWALL SCHEDULE (2) 2x6 TOP PLATES 7/16" OSB SHEATHING, FASTEN PER SHEARWALL SCHEDULE7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE 2x6 STUDS @ 24" O/C, ALIGN WITH JOISTS ABOVE PT 2x6 BOTTOM PLATES PER SHEARWALL SCHEDULE (2) 2x6 TOP PLATES 7/16" OSB SHEATHING, FASTEN PER SHEARWALL SCHEDULE (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAIN SCREEN PANEL EDGES PER A/S5.3 (3) 2x8 TOP PLATES PT 2x8 BOTTOM PLATES PER SHEARWALL SCH. 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE 2x4 PARAPET WALL FINISH GRADE EXCAVATE AS REQ'D (SEE SPECS) ROOF 113' - 0" A S3.2 S4.1 A 1 2 3 4.14 5 6 7 8 T.O. PARAPET 114' - 9" B S3.2 3/4" T&G PLYWOOD ROOF SHEATHING 1 1/8" T&G PLYWOOD SHEATHING COLUMN PER PLAN S5.1 D 18" BCI JOIST PER PLAN18" BCI JOIST PER PLAN 1 1/8" T&G PLYWOOD SHEATHING S5.1 A C S4.2 A S5.2 4" CONC. SLAB ON GRADE W/ W1.4xW1.4 6x6 WWM4" CONC. SLAB ON GRADE W/ W1.4xW1.4 6x6 WWM EXT. 4" SLAB W/ THICKENED EDGE (BEYOND) 4" EXTERIOR SLAB ON GRADE PER PLAN 5' - 0" S4.3 D (2)2x8 STUDS @ 24" O/C (3) 2x8 TOP PLATES PT 2x8 BOTTOM PLATES PER SHEARWALL SCH. 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAIN SCREEN PANEL EDGES PER A/S5.3 (3) 2x8 TOP PLATES 4" EXTERIOR SLAB ON GRADE PER PLAN (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAIN SCREEN PANEL EDGES PER A/S5.3 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAINSCREEN PANEL EDGES PER A/S5.3 PT 2x8 BOTTOM PLATES PER SHEARWALL SCH. 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE (3) 2x8 TOP PLATES (3) 2x8 TOP PLATES FINISH GRADE EXCAVATE AS REQ'D (SEE SPECS) DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S3.1 BUILDING SECTION SCALE: 1/4" = 1'-0" (22x34) A S3.1 TRANSVERSE BUILDING SECTION SCALE: 1/4" = 1'-0" (22x34) B S3.1 BULDING SECTION @ ENTRY (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR 100' - 0" ROOF 113' - 0" A S3.1 S4.2 A 18" BCI JOIST PER PLAN GLULAM BEAM PER PLAN SHEARWALL PER PLAN COLUMN PER PLAN @ RADIAL WALL 12" CONCRETE ELEVATOR PIT SLAB 4" CONC. SLAB ON GRADE W/ W1.4xW1.4 6x6 WWM S4.2 E A B C D E F F.2 G H T.O. PARAPET 114' - 9" (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAIN SCREEN PANEL EDGES PER A/S5.3 1 1/8" T&G PLYWOOD SHEATHING S4.1 D 4" EXTERIOR SLAB ON GRADE PER PLAN 6' - 0" PT 5 1/8"x18" GLULAM S5.2 A S4.3 D S4.3 A S5.2 C D S5.2 2x4 PARAPET WALL PER DETAIL D/S5.1 18" BCI BLOCKING @ 24" O/C 7/16" OSB SHEATHING, FASTEN PER SHEARWALL SCHEDULE 5" CONCRETE SLAB PER A/S2.2 EXCAVATE AS REQ'D (SEE SPECS) FINISH FLOOR 100' - 0" ROOF 113' - 0" A S3.1 ABCDEFF.2G T.O. PARAPET 114' - 9" B S3.1 (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAINSCREEN PANEL EDGES PER A/S5.3 S5.1 A S4.1 E 4" SLAB ON GRADE W/ W1.4xW1.4 6x6 WWM 18" BCI JOIST PER PLANGLULAM BEAM PER PLAN 1 1/8" T&G PLYWOOD SHEATHING GARAGE DOOR PER ARCH CONC. DRIVEWAY PER CIVIL S4.1 I EVAPORATIVE TRENCH J S4.1 2x4 PARAPET WALL PER DETAIL D/S5.1, TYP.18" BCI BLOCKING @ 24" O/C2x4 PARAPET WALL (3) 2x8 TOP PLATES PT 2x8 BOTTOM PLATES PER SHEARWALL SCHEDULE 7/16" OSB SHEATHING, FASTEN PER SHEARWALL SCHEDULE (2)2x8 STUDS @ 24" O/C, ALIGN STUD LAYOUT W/ RAINSCREEN PANEL EDGES A/S5.3 (3) 2x8 TOP PLATES 7/16" OSB SHEATHING, FASTEN PER SHEARWALL SCHEDULE EXCAVATE AS REQ'D (SEE SPECS) DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S3.2 BUILDING SECTION SCALE: 1/4" = 1'-0" (22x34) A S3.2 LONGITUDINAL BUILDING SECTION SCALE: 1/4" = 1'-0" (22x34) B S3.2 LONGITUDINAL BUILDING SECTION @ GARAGE (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR 100' - 0" 16"Wx24"D CONCRETE FOOTING , TYP. 4" SLAB ON GRADE W/ W1.4xW1.4 6x6 WWM 1 (4) #5 BARS, CONTINUOUS 10"x5/8" ANCHOR BOLT @ 48" O/C, UNLESS NOTED OTHERWISE ON SHEARWALL SCHEDULE PT BOTTOM PLATES PER SHEARWALL SCHEDULE 2" RIGID INSULATION GL #3 TIES @ 24" O/C 2' - 0"1' - 4" 7/16" OSB SHEATHING (2)2x8 STUDS @ 24" O/C FINISH FLOOR 100' - 0" FOOTING & REINFORCEMENT PER FOOTING SCHEDULE SLAB ON GRADE PER PLAN, CONTINUE REINFORCEMENT THROUGH FOOTING COLUMN PER PLAN 4.1 BASEPLATE & ANCHOR BOLTS PER FOUNDATION FINISH PLAN GL WIDTH PER PLAN FINISH FLOOR 100' - 0" WIDTH PER PLAN 10"x5/8" ANCHOR BOLT @ 48" O/C, UNLESS NOTED OTHERWISE ON SHEARWALL SCHEDULE 2x INTERIOR WALL SLAB ON GRADE PER PLAN, CONTINUE REINFORCEMENT THROUGH FOOTING REBAR PER SCHEDULE 7/16" OSB SHEATHING SLAB PER PLAN SAW CUT 1/4 OF SLAB DEPTH. FILL WITH 'SIKAFLEX' NOTE: CONTROL JOINTS CAN BE REPLACED W/ CONSTRUCTION JOINT PER F/S4.1 AS REQUIRED FOR CONTSRUCTION PHASING FINISH FLOOR 100' - 0" 1 4" SLAB ON GRADE PER PLAN FOOTING PER DETAIL A/S4.1 HOLDOWN PER PLAN. ALIGN W/ INSIDE EDGE OF STUD PT BOTTOM PLATES PER SHEARWALL SCHEDULE GL (2)2x8 STUDS @ 24" O/C THREADED ROD PER MFR W/ 3x3x1/4" WASHER, EMBED 8" FINISH FLOOR 100' - 0" FOOTING PER DETAIL D/S4.1 HOLDOWN PER PLAN. CENTER ON WALL. 2x INTERIOR WALL PER PLAN SLAB PER PLAN, CONINUE REINFORCEMENT THROUGH FOOTING THREADED ROD PER MFR W/3x3x1/4" WASHER, EMBED 9" FINISH FLOOR 100' - 0" G 5 3/4" CONC. W/(2) 2 1/4" INSULATION PANEL 'QUAD-LOK' FOUNDATION STEM WALL 6"Wx5"D MONOLITHIC FOOTING 2" RIGID INSULATION ABOVE "QUAD-LOK' FORM (2)2x8 STUDS @ 24" O/C HOLDOWN PER PLAN, ALIGN IN CENTER OF STEMWALL CONCRETE. THREADED ROD PER MFR W/3x3x1/4" WASHER, EMBED 7" INTO FOOTING FOOTING & STEMWALL PER DETAIL D/S4.2 1/2" DUROCK. FASTEN TO CONC. W/ POWER FASTENERS PER SPEC @ 12" O/C IN VERTICAL ROWS. SPACE 24" O/C MAX ALONG PANEL EDGES 7/16" OSB SHEATHING 4" SLAB PER PLAN #3 STIRRUPS @ 18" O/C (4) #5 REBAR LONGITUDINAL EAST JORDAN IRON WORKS #6904 TRENCH GRATE & FRAME1' - 2" GRATE 1' - 0" PIT CONC. DRIVEWAY PER CIVIL4" SLAB ON GRADE PER PLAN 24" LONG #5 SMOOTH REBAR @ 24" O/C 1/2" ASPHALT IMPREGNATED FIBERBOARD 2" RIGID INSULATION. TERMINATE @ BOTTOM OF THICKENED EDGE FOOTING PER DETAIL A/S4.1 SIKAFLEX SEALANT 1/2" RADIUS @ EDGE OF CONCRETE, TYP. PER ARCH'L GARAGE DOOR PER ARCH 4" CONC. SLAB ON GRADE W/W1.4xW1.4 6x6 WWM, TYP. 24" LONG #5 SMOOTH REBAR @ 24" O/C 1/2" EXPANSION MATERIAL DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S4.1 DETAILS SCALE: 1 1/2" = 1'-0" (22x34) A S4.1 TYP. EXTERIOR MONOLITHIC WALL FOOTING SCALE: 1 1/2" = 1'-0" (22x34) H S4.1 INTEROR MONOLITHIC COLUMN FOOTING SCALE: 1 1/2" = 1'-0" (22x34) D S4.1 TYP. INTERIOR MONOLITHIC WALL FOOTING SCALE: 3" = 1'-0" (22x34) C S4.1 TYPICAL CONTROL JOINT SCALE: 1 1/2" = 1'-0" (22x34) G S4.1 TYPICAL HOLDOWN @ EXT. WALL SCALE: 1 1/2" = 1'-0" (22x34) B S4.1 TYP. HOLDOWN @ INTERIOR WALL SCALE: 1" = 1'-0" (22x34) E S4.1 TYP. HOLDOWN @ STEM WALL SCALE: 1 1/2" = 1'-0" (22x34) J S4.1 EVAPORATIVE TRENCH DRAIN SCALE: 1 1/2" = 1'-0" (22x34) I S4.1 GARAGE DOOR THRESHOLD DETAIL SCALE: 1 1/2" = 1'-0" (22x34) F S4.1 TYPICAL CONSTRUCTION JOINT (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR 100' - 0" 1 1/2" CONC. SLAB W/ W1.4xW1.4 6x6 WWM 3/4" PLYWOOD SHEATHING2x8 JOIST @ 16" O/C 6" CONCRETE STEM WALL W/#4 REBAR @ 18" O/C, EACH WAY IN CENTER OF WALL 12" CONC. SLAB. SLOPE 1/8":12" TO SUMP 12"x12"x8" DEEP SUMP (BEYOND) SLAB PER PLAN D E 2x4 STUDS @ 16" O/C, TYP. CONC. FOOTING W/#5 REBAR @ 12" O/C, EACH WAY, T&B 6" TOP OF FOOTING B S4.2 WALL PER ARCH'L 12"Dx8"W THICKENED EDGE W/#5 REBAR, TYP. 96' - 0" 5 1/2"8' - 4"2" POWER FASTENERS @ 24" O/C, TYP. FINISH FLOOR 100' - 0" G 24"Wx10"D CONC. FOOTING W/(3) #5 REBAR CONT. 5 3/4" THICK CONC. WALL W/2 1/4" INSULATED 'QUAD-LOK' FORM #4 REBAR @ 16" O/C, EACH WAY 6"Wx5"D MONOLITHIC FOOTING PROVIDE 90 DEGREE HOOK @ EACH VERT. BAR 5" CONC. SLAB W/ REINFORCEMENT PER A/S2.5 24"LONGx2" RIGID INSULATION 1/2" DUROCK PANEL. ATTACH PER DETAIL E/S4.1 95' - 7" TOP OF FOOTING (=24.58' CIVIL) (=29.0' CIVIL) FINISH FLOOR 100' - 0" 5 3/4" THICK CONCRETE WALL W/ 2 1/4" INSULATED 'QUAD-LOK' FORM 4" CONC. SLAB W/ W1.4xW1.4 6x6 WWM #3x24" LONG SMOOTH DOWELED REBAR @ 48" O/C (GREASE ONE END) PT 5 1/8"x18" GLULAM BEAM G TYPE B 20GA METAL DECKING CUSTOM GLULAM SADDLE PER DETAIL A/S4.5 6"Wx5"D MONOLITHIC FOOTING 2" RIGID INSULATION FOOTING & REINFORCEMENT PER DETAIL D/S4.2 #4 REBAR @ 16" O/C, EACH WAY 5" CONC. SLAB W/ REINFORCEMENT PER A/S2.5 3/4"DIA THREADED ROD W/3x3x1/4" PLATE WASHER. REMOVE INSULATION AS REQ'D TO INSTALL WASHERS 95' - 7" TOP OF FOOTING (=29.0' CIVIL) (=24.58' CIVIL) SPRAY POLYURETHANE FOAM INSULATION PER ARCH. 60 MIL THICK POLYUREA COATING HOT DIPPED GALVANIZED HSS4x4x1/4" COLUMN THICKENED SLAB EDGE INCREASED TO 12" WIDE @ PILASTER 12" DIA PILASTER W/ (3) #5 REBAR VERT. EVENLY SPACED IN CIRCULAR LAYOUT, AND #3 TIES @ 8" O/C FOOTING & REINFORCEMENT PER FOOTING SCHEDULE BASEPLATE & ANCHOR BOLTS PER FOUNDATION FINISH PLAN (3) #3 TIES @ 2" O/C WRAP IN (2) LAYERS OF 6MIL POLYETHYLENE SHEETING PRIOR TO BACK FILL NFS GRAVEL 1 1/2" FINISH FLOOR 100' - 0" 5 6 7 CONC. FOOTING W/#5 REBAR @ 12" O/C, EACH WAY, T&B 2x6 INT. WALL, TYP.MONO FOOTING PER PLAN, TYP. TOP OF FOOTING 12"Dx8"W THICKENED EDGE W/#5 REBAR, TYP. 3/4" PLYWOOD SHEATHING2x8 JOIST @ 16" O/C 6" CONCRETE STEM WALL W/#4 REBAR @ 18" O/C, EACH WAY IN CENTER OF WALL 12" CONC. SLAB. SLOPE 1/8":12" TO SUMP 12"x12"x8" DEEP SUMP (BEYOND) 2x4 STUDS @ 16" O/C, TYP. 2x8 BLOCKING @ PERIMETER, TYP. 1 1/2" CONC. SLAB W/1.4x1.4 6x6 WWM 96' - 0" MONO FOOTING PER PLAN, TYP. SLAB PER PLAN 1' - 3 1/2"8' - 0"6 1/2" 6" POWER FASTENERS @ 24" O/C, TYP. DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S4.2 DETAILS SCALE: 1" = 1'-0" (22x34) A S4.2 ELEVATOR PIT TRANSVERSE SECTION SCALE: 1" = 1'-0" (22x34) D S4.2 FOUNDATION STEM WALL @ GL-G SCALE: 1 1/2" = 1'-0" (22x34) E S4.2 BEAM CONNECTION @ STEM WALL SCALE: 1" = 1'-0" (22x34) C S4.2 INDEPENDENT COLUMN BEARING SCALE: 1" = 1'-0" (22x34) B S4.2 ELEVATOR PIT LONGITUDINAL SECTION NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION (NO REVISIONS ON THIS SHEET)1 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR 100' - 0" H RADIAL WALL STUDS PER PLAN 4"X1/2"DIA. POST INSTALLED ANCHOR BOLTS @ 48" O/C. MIN. (2) PER WALL SECTION 5 1/4"Dx6"Wx1/4" BENT PLATE. FORM TO ALIGN W/ EDGE OF FRAMING 5 1/8"x18" GLULAM BEAM, TYP. 1 1/2" TYPE B 20GA METAL DECKING, TYP. 5" CONC. SLAB W/ REINFORCEMENT PER A/S2.5 ATTACH BENT PLATE W/4"x0.25" 'TIMBERLOK' FASTENERS @ 12" O/C 2" RIGID INSULATION (OVERHANG VARIES) HOLD BACK METAL DECKING 3" (R=29'-7 3/4") SPRAY POLYURETHANE FOAM INSULATION PER ARCH CEDAR 1x6 SOLID BLOCKING @ 16" O/C. THICKNESS VARIES ALONG RADIUS. EXTEND PHENOLIC PANELS 1/4" PAST BOTTOM OF GLULAMS 60 MIL THICK POLYUREA COATING FINISH FLOOR 100' - 0" H 16"x16" CONC. PILASTER 5 1/8"x18 GLULAM BEAM (3) #3 REBAR TIES @ 1 1/2" O/C @ TOP RADIAL WALL STUDS PER PLAN 5 1/4"Dx6"Wx1/4" BENT PLATE. FORM TO ALIGN W/ EDGE OF FRAMING (3) #3 REBAR TIES @ 1 1/2" O/C @ TOP BEAM SADDLE PER DETAIL B/S4.5 5" CONC. SLAB W/ REINFORCEMENT PER A/S2.5 1 1/2" TYPE B 20GA METAL DECKING 7/16" OSB WALL SHEATHING, TYP.S4.3 B 1' - 4" #3 HORIZ. TIES @ 8" O/C (8) #6 VERT. BARS SECTION AA 2' - 0" #3 HORIZ. TIES @ 8" O/C (11) #6 VERT. BARS SECTION BB A A B B VERT REBAR PER SECTION #3 REBAR TIES @ 8" O/C 16"x22" CONC. PILASTER VERT REBAR PER SECTION #3 REBAR TIES @ 8" O/C FOOTING & REINFORCEMENT PER FOOTING SCHEDULE 8" ELEV. = 95' - 11 1/4" TOP OF CONC. HOLD BACK METAL DECKING BACK 3" (R=29'-7 3/4") (3) DAYTON SUPERIOR DBDI SPLICE SYSTEM D102A 90DEG. HOOKED DOWEL BAR. #7 REBAR A=13". B=36" (3) DAYTON SUPERIOR DBDI SPLICE SYSTEM D103A 180DEG. HOOKED DOWEL BAR. #7 REBAR A=13". C=4" FINISH FLOOR 100' - 0" H 5 1/8"x18 GLULAM BEAM HSS4x2x1/4" POST, TYP. HOLD BACK METAL DECKING 3" (R=29'-7 3/4") 5 1/4"Dx6"Wx1/4" BENT PLATE. FORM TO ALIGN W/ EDGE OF FRAMING BASEPLATE & ANCHOR BOLTS PER FOUNDATION FINISH PLAN 1 1/2" TYPE B 20GA METAL DECKING #5 HAIRPIN, 36" LONG W/ 4" RADIUS TO EDGE OF FRAMING 3/4" EDGE OF POST ATTACH BENT PLATE W/4"x0.25" 'TIMBERLOK' FASTENERS @ 12" O/C 1x6 CEDAR PLATESPRAY POLYURETHANE FOAM INSULATION PER ARCH. 60 MIL THICK POLYUREA COATING 4" EXT. SLAB PER PLAN4" INT. SLAB PER PLAN 24" LONG #5 SMOOTH REBAR @ 24" O/C 1/2" EXPANSION MATERIAL 2" RIGID INSULATION FOOTING PER DETAIL A/S4.1 GL 2 1/2" PANELING 16"Wx24"D MONO FOOTING 24"Wx10"D FOOTING W/5 3/4" STEM WALL STEM WALL REINFORCEMENT PER DETAIL D/S4.2 (4) 30"x30" BENT #5 BARS ALIGNED W/ MONOLITHIC REINFORCEMENT FINISH FLOOR 100' - 0" 4" 4" SLAB ON GRADE REINFORCEMENT PER PLAN BEND REINFORCEMENT AS REQ'D TO MAINTAIN COVER 4" DIM PER ARCH'L 4" EXT. SLAB PER PLAN4" INT. SLAB PER PLAN 24" LONG #5 SMOOTH REBAR @ 24" O/C 2x2 NAILER 2" RIGID INSULATIONFOOTING PER DETAIL A/S4.1 GL 2x8 WALL (BEYOND) SLAB ELEVATION TO MATCH FINISH FLOOR @ DOOR.GRADE AWAY AS REQ'D TO MATCH SLAB ELEV. PER CIVIL 30" FROM DOOR. TEMPORARY DAYTON SUPERIOR PLUG DAYTON SUPERIOR DBD1 SPLICE SYSTEM RUBBER GASKET, TYP. 1 1/8" THREADED ROD W/ NUT & WASHER, TYP. DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S4.3 DETAILS SCALE: 1 1/2" = 1'-0" (22x34) B S4.3 RADIAL WALL BEARING SCALE: 1" = 1'-0" (22x34) A S4.3 RADIAL FOOTING & PILASTER @ OVERSLOPE SCALE: 1 1/2" = 1'-0" (22x34) C S4.3 COLUMN @ RADIAL WALL BEARING SCALE: 1 1/2" = 1'-0" (22x34) D S4.3 TYPICAL CONSTRUCTION JOINT @ EXT. SLAB SCALE: 1 1/2" = 1'-0" (22x34) E S4.3 MONO FOOTING TO STEM WALL SCALE: 1 1/2" = 1'-0" (22x34) F S4.3 2" SLAB RECESS SCALE: 1 1/2" = 1'-0" (22x34) G S4.3 MAN DOOR THRESHOLD COLUMN, FOOTING, AND STEEL BEAM SEATS ARE INCLUDED IN "COMBINED COLUMNS FOR HABROMASTER OFFICE/ BOARDWALK" BID ITEMS (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION (NO REVISIONS ON THIS SHEET)1 2 2 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands 2 1/4" 2" GL (W) DIM2 1 1/4"1 1/4" 1 1/4" GL 1/4" NOTE: 1). ALL BASEPLATES ARE 1/4" PLATE 2.) ELEVATION REFERS TO BOTTOM OF BASEPLATE 4 1/2" NOTE: 1). ALL BASEPLATES ARE 1/4" PLATE 2). ELEVATION REFERS TO BOTTOM OF BASEPLATE 3). PLATE B3.4, B3.5, AND B3.6 SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION. EQEQ 1 1/4" GL DIM2 GL (W) 1/4" NOTE: 1). ALL BASEPLATES ARE 1/4" PLATE 2).ELEVATION REFERS TO BOTTOM OF BASEPLATE GL GL 1 1/4" EQ EQ (W) DIM2 1/4" NOTES: 1). ALL BASEPLATES ARE 1/4" PLATE 2). ELEVATION REFERS TO BOTTOM OF BASEPLATE 3). ALIGN EDGE OF PLATE W/ EDGE OF FRAMING, TYP. 4). ANCHOR BOLTS TO BE WELDED TO BOTTOM SIDE OF BASEPLATE EQ EQ 1/4" PLATE TO COLUMN (W) OUTSIDE EDGE OF FRAMING 1 1/4"1 1/4" 1/4" ANCHOR BOLT TO PLATE GL DIM1 DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S4.4 FOUNDATION BASEPLATES SCALE: 3" = 1'-0" (22x34) A S4.4 BASEPLATE TYPE B1 SCALE: 3" = 1'-0" (22x34) C S4.4 BASEPLATE TYPE B3 SCALE: 3" = 1'-0" (22x34) B S4.4 BASEPLATE TYPE B2 BASEPLATE TYPE B1 SCHEDULE PLATE # LENGTH, L WIDTH, W COLUMN GL / DIM1 GL / DIM2 ELEVATION ANCHOR BOLT B1 6 3/4" 6 1/2" HSS3 1/2X3 1/2X5/16 F / 2 5/8" 2 / 5" 100'-0" 5/8"X10" LONG BASEPLATE TYPE B2 SCHEDULE PLATE #LENGTH, L WIDTH, W COLUMN GL / DIM1 GL / DIM2 ELEVATION ANCHOR BOLT B2.1 3 1/2" 8" HSS3X3X1/4 D / 1 3/4" 5 / 1'-1 3/4" 100'-0" 5/8" X 10" LONG B2.2 3 1/2" 8" HSS3X3X1/4 D / 1 3/4" 5 / 9'-5 1/4" 100'-0" 5/8" X 10" LONG B2.3 3 1/2" 8" HSS3X3X1/4 E / 1 3/4" 5 / 1'-1 3/4" 100'-0" 5/8" X 10" LONG B2.4 3 1/2" 8" HSS3X3X1/4 E / 1 3/4" 5 / 9'-5 1/4" 100'-0" 5/8" X 10" LONG B2.5 3 1/2" 8" HSS3X3X1/4 C / 4'-10 3/4" 6 / 2'-6 1/4" 100'-0" 5/8" X 10" LONG B2.6 3 1/2" 8" HSS3X3X1/4 D / 1 3/4" 6 / 2'-6 1/4" 100'-0" 5/8" X 10" LONG BASEPLATE TYPE B3 SCHEDULE PLATE # LENGTH, L WIDTH, W COLUMN GL / DIM1 GL / DIM2 ELEVATION ANCHOR BOLT B3.1 10" 5 1/2" HSS5x5x3/8" G / 0'-2 5/8" R4 / 0" 100'-0" 5/8"DIAx10" LONG B3.2 10" 5 1/2" HSS5x5x3/8" G / 4'-8" R4 / 0" 100'-0" 5/8"DIAx10" LONG B3.3 10" 5 1/2" HSS5x5x3/8" F.2 / 0" R4 / 0" 100'-0" 5/8"DIAx10" LONG B3.4 9" 4 1/2" HSS4x4x1/4" C / 5'-6" 3 / 3'-11" 99'-4" 5/8"DIAx10" LONG B3.5 9" 4 1/2" HSS4x4x1/4" C / 5'-6" 3 / 12'-11" 99'-4" 5/8"DIAx10" LONG B3.6 9" 4 1/2" HSS4x4x1/4" C / 5'-6" 5 / 6" 99'-4" 5/8"DIAx10" LONG SCALE: 3" = 1'-0" (22x34) D S4.4 BASEPLATE TYPE B6 BASEPLATE TYPE B6 SCHEDULE PLATE # LENGTH, L WIDTH, W COLUMN GL / DIM1 ELEVATION ANCHOR BOLT B6.1-B6.7 5 1/2" 4" HSS4x2x1/4" R1-R7 / 0" 100'-0" 5/8"x4" NELSON STUD B6.8-B6.15 5 1/2" 4" HSS4x2x1/4" R1-R7 / 4'-3 1/4" 100'-0" 5/8"x4" NELSON STUD B6.16 7" 4" HSS6x3x1/4" 8 / 3 3/4" 100'-0" 5/8"DIAx8"LONG (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands G R4 1 1/2" TYP. FRONT ELEVATION 5 1/4" 3/8" PLATE 3/4"DIA. BOLT, TYP. 1/4" PLATE, TYP. 1/4" FLARE TOP OF VERT. PLATE, TYP. 5 1/4" (SEE SECTION AA) TYP. SIDE ELEVATION 1/4" PLATE 3/8" PLATE 3/4"DIA. BOLT, TYP. 2" 8" SECTION AA @ R4 SECTION AA @ R5 & R3 SECTION AA @ R6 & R2 SECTION AA @ R7 & R1 1' - 0"1' - 0"1' - 2"1' - 4 3/4" 9 3/8"6"6" (MIRROR FOR R1) 1 1/2"1 1/2"1 1/2"1 1/2"1 1/2"1 1/2"1 1/2"1 1/2" SECTION AA @ R8 & R0 (MIRROR FOR R0)(MIRROR FOR R2)(MIRROR FOR R3) A A A A 7 1/2" 1' - 2" 1 1/2"1 1/2" 7 1/2" 3/4"DIA. BOLT W/1"x13/16" SLOTTED HOLE 3"x3"x1/4" PLATE WASHER, TYP. NOTE: ALL HARDWARE ON THIS SHEET SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION R.X 1/4" 1/4" TYP. 12"x9"x1" BASEPLATE 5/8"DIAx10" NELSON STUD, TYP. 1/4" TYP. 1/4" 1/4" TYP. 1/4" PLATE, TYP.5 1/4" 5 1/4" (4) 5/8"DIAx10" NELSON STUDS, BELOW, TYP. TYP. FRONT ELEVATION 12"x9"x1" BASEPLATE. 1/4" PLATE, TYP. CENTERLINE WORKING POINT COORDINATE. SEE SHEET S2.1 2 1/2"2 1/2" 3/4"DIA. BOLT, TYP. CENTER ON FLANGE 12"x9"x1" BASEPLATE 5/8"DIAx10" NELSON STUD, TYP. 1/4" TYP. 1/4" ANGLED PLATE TYP. SIDE ELEVATION 1 3/8"2 1/2" 3/4"DIA. BOLT, TYP. CENTER ON FLANGE SECTION BB A A A A PILASTER PER PLANPILASTER PER PLAN 16"x16" CONC. PILASTER BELOW 1/4" 1/4" TYP. 3/4"DIA. BOLT W/1"x13/16" VERTICAL SLOTTED HOLE DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S4.5 FOUNDATION BEAM SADDLES SCALE: 1 1/2" = 1'-0" (22x34) A S4.5 FOUNDATION STEM WALL RADIAL BEAM SADDLES SCALE: 3" = 1'-0" (22x34) B S4.5 RADIAL BEAM SADDLE @ PILASTER (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands ROOF 113' - 0" 1 1/8" T&G PLYWOOD SHEATHING (3) 2x8 TOP PLATES (2)2x8 STUDS @ 24" O/C 18" BCI 90 2.0 @ 24" O/C PARAPET WALL W/2x4 (FLAT) STUDS @ 16" O/C 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEUDLE BLOCK JOISTS @ BEARING LOCATIONS W/ 2x6 EACH SIDE OF WEB 1 1/4"x18" VERSARIM, TYP. 8 2x4 T-BRACE @ 16" O/C 7/16" OSB SHEATHING T.O. PARAPET 114' - 9" SIMPSON H3 @ EACH STUDS 2x6 TOP PLATE GL ATTACH STUD TO PLATE W/ SIMPSON H6 TIE @ EACH STUD (4) 16D NAILS 8D NAILS @ 6" O/C (2) 6"x0.25" TIMBERLOK FASTENERS EACH SIDE OF WEB (4 TOTAL) SIMPSON H6 @ EACH JOIST ROOF 113' - 0" F.2 B ELEVATION 1 1/8" T&G PLYWOOD SHEATHING16D NAILS @ 16" O/C COLUMN PER PLAN 2x4 WALL (BEYOND) SIMPSON ECCO 5 1/4" COLUMN CAP 5 1/8"x18" GLULAM BEAM @ 48" O/C18" BCI 90-1.2 @ 24" O/C B 1/4" 10D @ 4" O/C BEAM PER SCHEDULE BEAM PER SCHEDULE PLYWOOD SHEATHING JACK STUDS PER PLAN (NOT LESS THAN 2) KING STUDS PER PLAN (NOT LESS THAN 2) (6) ¼" DIA TIMBERLOK SCREWS W/ 3" EMBED INTO HEADER ELEVATIONSECTION 'AA' ROOF 113' - 0" 8 T.O. PARAPET 114' - 9" 1 1/8" T&G PLYWOOD SHEATHING (3) 2x8 TOP PLATES (2)2x8 STUDS @ 24" O/C. PARAPET WALL W/2x4 (FLAT) STUDS @ 16" O/C 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEUDLE PROVIDE (2)SIMPSON H6 STRAPS @ EACH BEAM 1 1/4"x18" VERSARIM, TYP. 2x4 T-BRACE @ 16" O/C 7/16" OSB SHEATHING SIMPSON H3 @ EACH STUD 2x6 TOP PLATE 3 1/8"x18" GLULAM BEAM (4) 16D NAILS 8D NAILS @ 6" O/C ATTACH STUD TO PLATE W/ SIMPSON H6 TIE @ EACH STUD 18" BCI 90 2.0 BLOCKING ABOVE BEARING WALL 18" BCI 90 2.0 @ 24" O/C, PER PLAN (2) 2x6 TOP PLATES 2x6 STUDS @ 24" O/C. ALIGN WITH JOISTS 7/16" OSB SHEATHING AS REQUIRED PER SHEARWALL PLAN 1 1/8" T&G PLYWOOD SHEATHING, TYP. BLOCK WEB W/2x6, EACH SIDE @ BEARING WALL BLOCK WEB W/2x6, EACH SIDE @ BEARING WALL 1 1/8" PLYWOOD SHEATHING, TYP. 18" BCI 90 2.0 BLOCKING ABOVE BEARING WALL 18" BCI 90 2.0 @ 24" O/C, PER PLAN (2) 2x6 TOP PLATES 2x6 STUDS @ 24" O/C. ALIGN WITH JOISTS ELEVATION SECTION CC 10D NAILS @ 6" O/C (2) 16D NAILS @ 8" O/C 2 F F.2 SECTION BB 2x4 INTERIOR SHEARWALL 2x6 INTERIOR SHEARWALL NOTE: BCI LAYOUT TO ORIGINATE DIRECTLY ADJACENT TO HSS COLUMN HSS3 1/2"x3 1/2"x5/16" (SCALE: 3/4"=1'-0") DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S5.1 DETAILS SCALE: 1 1/2" = 1'-0" (22x34) D S5.1 TYP. EXTERIOR JOIST BEARING SCALE: 1 1/2" = 1'-0" (22x34) C S5.1 JOIST & GLB BEARING @ INTERIOR WALL SCALE: 1 1/2" = 1'-0" (22x34) A S5.1 TYPICAL HEADER SCALE: 1 1/2" = 1'-0" (22x34) B S5.1 GLULAM BEARING @ EXTERIOR WALL SCALE: 1 1/2" = 1'-0" (22x34) E S5.1 TYP. JOIST BEARING @ INTERIOR WALL (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands C 2x10 LEDGER, TYP. 2x6 JOISTS @ 24" O/C, ALIGN W/ PANEL JOINTS PER ARCH'L 2x6 STUDS @ 16" O/C, ALIGN W/ PANEL JOINTS PER ARCH'L 4x10 3/4" T&G PLYWOOD SHEATHING 12" LONG L8x3x1/4" 1/4" (2)2x8 STUDS @ 24" O/C (4) 5/8" BOLTS, TYP.SIMPSON LU26 HANGER @ EACH JOIST (3) 4"x0.25" TIMBERLOK FASTENERS @ EACH STUD SIMPSON LU210 HANGER @ EACH JOIST 2x6 LEDGER 2x10 JOISTS @ 24" O/C 4"x0.25" TIMBERLOK FASTENERS @ 24" O/C BLOCK AS REQ'D 1/2" PLYWOOD SHEATHING ROOF 113' - 0" T.O. PARAPET 114' - 9" 2x4 STUDS @ 16" O/C SIMPSON ECCO 3 1/4" COLUMN CAP, TYP HSS4x2x1/4" 3 1/8"x18"GLB 1 1/8" T&G PLYWOOD ROOF SHEATHING 2x4 (FLAT) @ END OF EACH GLULAM BEAM, TYP. ATTACH 2x4(FLAT) STUD TO END OF GLULAM W/(5) 1/4"x5" TIMBERLOCK FASTENERS, TYP. 1/4" 3/4" 2 LAYERS 3/4" PLYWOOD PLATE 2 LAYERS 3/4" PLYWOOD PLATE HSS4x2x1/4" POST2x4 STUDS PER PLAN 7/16" OSB SHEATHING 3/4" PLYWOOD SHIM PHENOLIC PANEL & HAT CHANNEL PER ARCH'L1.5"Lx#12 SELF DRILLING STAINLESS STEEL NEOPRENE WASHERED FASTENER @ 12" O/C MAX. TYP. PANEL TO FURRING 2x8 EACH SIDE OF POST, TYP. ROOF 113' - 0" T.O. PARAPET 114' - 9" 2x4 STUDS @ 16" O/C 1 1/8" T&G PLYWOOD ROOF SHEATHING 2x4 (FLAT) @ 16" O/C ATTACH 2x4(FLAT) STUD W/(4) 2 1/2" #8 SCREWS SPACED 3" O/C 2 LAYERS 3/4" PLYWOOD PLATE 2 LAYERS 3/4" PLYWOOD PLATE 7/16" OSB SHEATHING, TYP. 1 1/4"x18" VERSARIM PLATE CURVED 2x8 TOP PLATE RADIAL WALL STUDS PER PLAN 2 1/2" #8 SCREWS @ 6" O/C 1/4" 1/4" 1/4" 1/4" 4x10 HEADER 5 1/8"x12" GLULAM BEAM HSS6x3x1/4" POST 2x8 PLATE EACH SIDE OF POST 1/4" PLATE BEAM HANGER ATTACH BEAM W/(2) 5/8"DIA. BOLTS, TYP.3 1/2" 3 1/2" 7 1/4"x3 1/2"x1/4" PLATE (3) 4"x0.25" TIMBERLOCK FASTENERS, EACH SIDE (6 TOTAL)1/4" TRIPLE TOP PLATE, TYP. ROOF 113' - 0" 1 1/8" PLYWOOD ROOF SHEATHING 1 3/4"x18" VERSALAM 18" 90 2.0 BCI JOISTS @ 24 O/C18" 90 2.0 BCI JOISTS @ 24 O/C MIU3.56/18 @ EACH JOIST, TYP. ROOF 113' - 0" 1 1/8" PLYWOOD ROOF SHEATIHNG SIMPSON MIU3.56/18 HANGER @ EACH JOIST, TYP.3 1/8"x18" GLULAM GIRDER BEAM 18" 90 2.0 BCI JOIST @ 24" O/C18" 90 2.0 BCI JOIST @ 24" O/C SHEARWALL EDGE NAILING PER SHEARWALL SCHEDULE SHEARWALL EDGE NAILING PER SHEARWALL SCHEDULE BLOCKING AS REQ'D COLUMN PER PLAN SIMPSON 2 3/8" TB SCREWS @ 12" O/C, TYP. SHEATHING PER SHEARWALL SCHEDULE PANEL EDGE NAILING PER SHEARWALL SCHEDULE16D NAILS @ 4" O/C 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE 7/16" OSB SHEATHING. FASTEN PER SHEARWALL SCHEDULE DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S5.2 DETAILS SCALE: 1" = 1'-0" (22x34) A S5.2 ENTRY CANOPY FRAMING SCALE: 1 1/2" = 1'-0" (22x34) C S5.2 POST CAP @ RADIAL WALL SCALE: 3" = 1'-0" (22x34) D S5.2 POST @ RADIAL WALL SCALE: 1 1/2" = 1'-0" (22x34) B S5.2 TYP. EAVE @ RADIAL WALL SCALE: 1 1/2" = 1'-0" (22x34) E S5.2 BEAM & HEADER CONNECTION TO POST SCALE: 1 1/2" = 1'-0" (22x34) F S5.2 JOIST HANGER @ BCI GIRDER SCALE: 1 1/2" = 1'-0" (22x34) G S5.2 JOISTS HANGER @ GLULAM GIRDER SCALE: 3" = 1'-0" (22x34) H S5.2 SHEARWALL END MEMBER TO HSS COLUMN SCALE: 1 1/2" = 1'-0" (22x34) I S5.2 SHEARWALL SPLICE 1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands ALIGN WALL STUD LOCATION WITH PANEL JOINTS NOTE: FASTEN FURRING INTO ALIGNED STUD. IN THE CASE OF MISALIGNED STUDS PROVIDE HORIZONTAL BLOCKING PREFINISHED EXTRUDED ALUMIN VERTICAL FURRING. PROVIDE 0.09" THICK NORTHCLAD HATS, ZEES AND CLOSURES AS REQUIRED 1.5" LONG X #12 SELF DRILLING STAINLESS STEEL NEOPRENE WASHERED FASTENER @ 12" O/C MAX. TYPICAL FURRING TO STUD. #12 SELF DRILLING STAINLESS STEEL NEOPRENE WASHERED FASTENER @ 24" O/C MAX. TYPICAL PANEL TO FURRING . RAINSCREEN PANEL SEE ARCH INTERIOR FINISH SEE ARCH EXTERIOR SHEATHING ROOF 113' - 0" F 3 1/8"x18" GLULAM BEAM 3 1/8"x18" GLULAM BEAM SIMPSON HGUS3.25/10 HANGER 1 1/8" T&G PLYWOOD SHEATHING 2x FRAMING BEAM PER PLAN TRIPLE TOP PLATE (2) 2x STUDS @ EACH SIDE OF BEAM BLOCK SOLID UNDERNEATH BEAM DOWN TO FOOTING BEAM PER PLAN PLAN VIEW SECTION AA AA PLAN VIEW SECTION BB (3) 2x8 TOP PLATES 6 3/4"x24" GLULAM BEAM (2) SIMPSON LS70 ANGLES 2x HORIZ. BLOCKINGSIMPSON CS16 STRAP (3)4"x0.25" TIMBERLOK FASTENERS, EACH SIDE BLOCK SOLID UNDERNEATH BEAM, DOWN TO FOOTING 6 3/4"x24" GLULAM BEAM SIMPSON CS16 STRAP CUT BACK BEAM & WALL AS REQUIRED 16D NAILS @ 6" O/C (2) SIMPSON LS70 ANGLES, EACH SIDE OF TOP PLATES ROOF 113' - 0" R8 GLULAM BEAM PER PLAN 2x6 LEDGER, TYP. 4"x0.25" TIMBERLOK FASTENERS @ 4" O/C 2x10 JOISTS @ 12" O/C 1 1/8" T&G PLYWOOD SHEATHING SIMPSON L70 SKEWED ANGLE @ EACH JOIST, TYP. HEADER PER PLAN WINDOW OPENING 1' - 0" MIN SIMPSON CS16 STRAP, TYP. EXTEND MIN. 12" BEYOND KING STUD W/(18) 8D NAILS BEYOND KING STUD KING STUD PER PLAN JACK STUD PER PLAN BLOCK BEHIND STRAP AS REQ'D RAINSCREEN PANEL SEE ARCH EXTERIOR SHEATHING ATTACH W/(2) 5"LONGx#12 SELF DRILLING STAINLESS STEEL NEOPRENE WASHERED FASTENER, ALIGN WITH STUDS, TYP. ROOF ACCESS LADDER PER ARCH'L. ALUMINUM BRACKET PER MFR STUDS PER PLAN DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S5.3 DETAILS SCALE: 1 1/2" = 1'-0" (22x34) A S5.3 RAINSCREEN PANEL TYPICAL ATTACHMENT PLAN VIEW SCALE: 1 1/2" = 1'-0" (22x34) B S5.3 GLULAM BEAM HANGER SCALE: 1 1/2" = 1'-0" (22x34) C S5.3 TYP. BEAM POCKET SCALE: 1 1/2" = 1'-0" (22x34) D S5.3 RADIAL WALL FRAMING @ CORNER SCALE: 1 1/2" = 1'-0" (22x34) E S5.3 JOIST LEDGER CONNECTION SCALE: 1 1/2" = 1'-0" (22x34) F S5.3 HORIZONTAL WINDOW STRAPPING SCALE: 1 1/2" = 1'-0" (22x34) G S5.3 LADDER ATTACHMENT (NO REVISIONS ON THIS SHEET)1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION (NO REVISIONS ON THIS SHEET)1 240320 PACAB Work Session Laydown-Uplands 1 1/4" 10 3/4" 5 1/4" 8" 1/4" PLATE SADDLE 3/8" PLATE 1/4" 1/4" 3/8" PLATE (4) 3/4"DIA BOLTS, TYP. (2) 3/4"DIA BOLTS, TYP. TYP. FRONT ELEVATION TYP. SIDE ELEVATION 5 1/4" 10 3/4" 1 1/4"1 1/4" 5 3/8" FLARE TOP OF VERT. PLATE,TYP. (10)SECTION BB @ F2 B B B B 1' - 1" 7" 1 1/4"1 1/4" 1' - 0 1/4" 6 1/2" 1 1/4"1 1/4" 3 F.2 1'-10 9/16" (NTS) (11)SECTION BB @ R2 & R6 (12)SECTION BB @ R8 G R8 6 0'-8 7/8" (NTS) (MIRROR FOR R6) 6" 1 1/4" 8 3/4" 3 1/4" 8" 1/4" PLATE SADDLE 3/8" PLATE 1/4" 3/8" PLATE (4) 3/4"DIA BOLTS, TYP. (2) 3/4"DIA BOLTS, TYP. FLARE TOP OF VERT. PLATE, TYP. TYP. FRONT ELEVATION TYP. SIDE ELEVATION 8 3/4" 1 1/4"1 1/4" 4 3/8" 3 1/4" 9" 1 1/4" 4 1/2" 9" 1 1/4" 4 1/2" 9" 1 1/4" 4 1/2" 9 3/4" 5 1/8" 9" 4 1/2" 9" 4 1/2" (1)SECTION AA @ F.4 (2)SECTION AA @ R0.5 & R7.5 (3)SECTION AA @ R1 & R7 (4)SECTION AA @ R1.5 & R6.5 (5)SECTION AA @ R2.5 & R5.5 (6)SECTION AA @ R3 & R5 (7)SECTION AA @ R3.5 & R4.5 (MIRROR FOR R7.5)(MIRROR FOR R7)(MIRROR FOR R6.5) (MIRROR FOR R5.5)(MIRROR FOR R5)(MIRROR FOR R4.5) A A A A 1 1/4"1 1/4"1 1/4"1 1/4"1 1/4"1 1/4" 1 1/4"1 1/4"1 1/4" F.2 3 3'-9 1/2" (NTS)EQ. G G G (2) 3/4"DIA BOLTS, TYP. R0 &R8 SIDE ELEVATION 6 1/2" MIN. 1/4" PLATE SADDLE 6" 6" 1 2 1' - 8" 7 1/2" (8)SECTION AA @ R0 & R8 (MIRROR FOR R8) 1 1/4"1 1/4" R0 (SCALE: 1 1/2" = 1'-0") 2' - 0" 1 1/4" 1' - 2" 1 1/4" R0 (9)SECTION BB @ RO & R8 (MIRROR FOR R8) (SCALE: 1 1/2" = 1'-0") DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S5.4 DETAILS SCALE: 3" = 1'-0" (22x34) B S5.4 5 1/4" GLULAM BEAM HANGER SCALE: 3" = 1'-0" (22x34) A S5.4 3 1/4" GLULAM BEAM HANGER 1 1 1 1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands R0 1' - 0 1/4" 1 1/4"1 1/4" 6" 5 3/4" 1 1/4" 10 3/4" 5 1/4" 1/4" PLATE SADDLE 3/8" PLATE 1/4" 1/4" 3/8" PLATE (4) 3/4"DIA BOLTS, TYP. (2) 3/4"DIA BOLTS, TYP. TYP. FRONT ELEVATION TYP. SIDE ELEVATION FLARE TOP OF VERT. PLATE,TYP. A A A A (13) SECTION AA @ R0 1 1/4" 8"8" 5 1/8" R4 G 1 1/4" 10 3/4" 5 1/4" 4" 1/4" PLATE SADDLE 3/8" PLATE 1/4" 1/4" 3/8" PLATE (4) 3/4"DIA BOLTS, TYP. (2) 3/4"DIA BOLTS, TYP. TYP. FRONT ELEVATION TYP. SIDE ELEVATION FLARE TOP OF VERT. PLATE,TYP. B B B B 4" (14) SECTION BB @ R4 5 1/4" 1' - 1" R4 F.2 (15)SECTION CC 1' - 1" 3/8" PLATE TYP. FRONT ELEVATION SIDE ELEVATION C C ANGLED BEAM HANGER PERP. BEAM HANGER (BEYOND) ANGLED BEAM HANGER (BEYOND) 1/4" COLUMN TO CAP 1/4" COLUMN TO CAP 1' - 4 1/2" COLUMN PER PLAN 4 7/8" (2) 3/4"DIA. BOLTS, TYP. DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S5.5 DETAILS SCALE: 3" = 1'-0" (22x34) A S5.5 SKEWED DOUBLE BEAM HANGER SCALE: 3" = 1'-0" (22x34) B S5.5 DOUBLE BEAM HANGER SCALE: 3" = 1'-0" (22x34) C S5.5 MULTI BEAM COLUMN CAP 1 1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FINISH FLOOR 100' - 0" ROOF 113' - 0" T.O. PARAPET 114' - 9" CURVED 2x8 TOP PLATE RADIAL WALL STUDS PER PLAN ATTACH END STUD TO STEEL POST W/(6) HILTI X-AL-H POWER FASTENERS @ EQUAL SPACE, TYP. ATTACH HEADER TO END STUD W/(4) 16D NAILS, TYP. (EACH SIDE) 2x8 HEADER STEEL POST PER PLAN CURVED 2x8 PLATE, TYP. (OPENING)(OPENING) SECTION AA SECTION BB B B 2x8 HEADER, LOCATE @ CENTER OF HSS POST, TYP 2x8 STUD @ EACH END OF WALL PANEL STUDS PER S2.6 (ENLARGED ROOF FRAMING @ OVERSLOPE) 2x8 HEADER, LOCATE @ CENTER OF HSS POSTS, TYP. R2 1' - 0 1/4" 1 1/4"1 1/4" 6" 5 3/4" 1 1/4" 10 3/4" 5 1/4" 1/4" PLATE SADDLE 3/8" PLATE 1/4" 1/4" 3/8" PLATE (4) 3/4"DIA BOLTS, TYP. (2) 3/4"DIA BOLTS, TYP. TYP. FRONT ELEVATION TYP. SIDE ELEVATION FLARE TOP OF VERT. PLATE,TYP. A A A A (19) SECTION AA @ R2 & R6 1 1/4" (MIRROR FOR R6)DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: SHEET NUMBER SHEET CONTENTS REVISIONS: 4321 4321 D C B A D C B A ZSR CAM WJN 07/11/2014 CONFORMED DRAWING SET 1358 7-11-14 S5.6 DETAILS SCALE: 1" = 1'-0" (22x34) A S5.6 FRAMING ELEVATION @ RADIAL WALL 1 SCALE: 3" = 1'-0" (22x34) B S5.6 SKEWED DOUBLE BEAM HANGER (2) 1 NO. DATE 1 06/10/14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 2 2 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION Upgrade includes electrofin coating on evaporator, condenser and hot water coils Kohler Kingston K-2007-0 Lavatory Sloan Optima 4 Faucet1 1 1 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 1 1 Record Drawings 11-2016 1 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION With Manual Dampers (Typical) 1 1 1 1 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 1 1 Record Drawings 11-2016 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1 240320 PACAB Work Session Laydown-Uplands CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands DENOTES AVAILABLE FAULT CURRENT PHOTOCELL CONTROL LUMINAIRE TYPE AS NOTED ON PLAN SWITCH LEGEND 3 (THREE WAY);4 (FOUR WAY); L (LOW VOLTAGE); D (DIMMER); K (KEYED); P (PILOT LIGHT); V (VARIABLE SPEED CONTROL); OC (OCCUPANCY SENSOR); T (INTEGRAL MOTOR OVERLOAD [WHERE FHP MOTOR REQUIRES AUTOMATIC CONTROL PROVIDE MOTOR RATED "RELAY IN BOX"]) FUSEDSAFETY SWITCH / DISCONNECT METERING DEVICE MOTOR CONNECTION NON FUSEDSAFETY SWITCH / DISCONNECT ENCLOSED CIRCUIT BREAKER SWITCH MOTOR STARTER PUSH BUTTON CONTROL STATION SIMPLEX RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE GFCI PROTECTED POWERDISTRIBUTION PANELBOARD EXTERIOR LIGHT FIXTURE, POLE MOUNTED, HEADS AS SHOWN LUMINAIRE WALL MOUNTED: TYPE AS NOTED ON PLAN TRACK LIGHTING TRACK LENGTH AS SCALED: TYPE AS NOTED ON PLAN EMERGENCY LIGHTING UNIT (WALL;CEILING; REMOTE HEAD) EXIT SIGN (CEILING; WALL);SHADE DENOTES FACE; ARROWS AS INDICATED SWITCH SINGLE POLE, SINGLE THROW, UON JUNCTION BOX OR EQUIPMENT CONNECTION FLEX OR RECEPTACLE AS REQUIRED (CEILING; WALL; FLOOR) RECEPTACLE FLUSH MOUNTED IN CEILING POWER PANELBOARD TRANSFORMER: APPROX. PHYSICAL SIZE AS SCALED; ACTUAL RATING AS NOTED ON ONE LINE DIAGRAMS COMBINATION MOTOR STARTER SAFETY SWITCH / DISCONNECT COMBINATION BATHROOM FAN/LIGHT: TYPE AS NOTED ON PLAN DUPLEX RECEPTACLE SPLIT WIRED FOR SWITCH CONTROL OF LOWER OUTLET DUPLEX RECEPTACLE GFCI PROTECTEDMOUNTED ABOVE COUNTERTOP DUPLEX RECEPTACLE FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLOOR MOUNTED RECEPTACLE PENDANT MOUNTED FROM CEILING WITHKELLUM GRIPS DRYER RECEPTACLE 30A, 3 POLE, 4 WIRE NEMA 14 30R ELECTRIC RANGE RECEPTACLE 50A, 3 POLE, 4 WIRE, NEMA 14 50R SPECIAL RECEPTACLE COORDINATE EXACT NEMA CONFIGURATION IF NOT NOTED (SURFACE; WALL) TELECOMMUNICATION OUTLET(WALL; FLOOR) TELEPHONE VOICE OUTLET LINETYPE/LINEWEIGHT DENOTING DEMO WORK LINETYPE/LINEWEIGHT DENOTING NEW WORK LINETYPE/LINEWEIGHT DENOTINGEXISTINGWORK TO REMAIN LINETYPE/LINEWEIGHT DENOTING FUTURE WORK GROUND CONNECTION POINT CONTROL PANEL TYPE AS NOTED (SURFACE; RECESSED) LUMINAIRE EMERGENCY LIGHT TELEVISION OUTLET RG 6 QUAD SHIELD HOMERUN, UON 2H 15a A3[6] a THE NUMBERIN BRACKETS INDICATES HOW MANY TYPICAL LUMINAIRES OF THIS TYPE ARE IN THIS AREA EQUIPMENT TAG LEGEND ELECTRICAL LEGEND CIRCUIT AND SWITCHLEG PANEL TYPICAL LUMINAIRE LOWER CASE LETTER DENOTES SWITCH LEG FOR CORRESPONDING LUMINAIRE CONTROL LUMINAIRES CONTROL SWITCHES LUMINAIRE TYPE (UNDERLINED) UPPERCASE LETTER OR NUMBER DENOTES SWITCH CONFIGURATION EQUIPMENT ID (UNDERLINED) REFER TO EQUIPMENT CONNECTION SCHEDULE FOR REQUIREMENTS EQUIPMENT CONNECTIONS TYPICAL EQUIPMENT (MOTOR STARTER SHOWN) AHU 1 A 1,3,5 PANEL CIRCUIT NUMBER(S) RECEPTACLES NEMA CONFIGURATION FOR SPECIAL RECEPTACLES (UNDERLINED) MOUNTING HEIGHT AFF PANEL L5 20R +48" CIRCUIT NUMBER(S) 2L 1,3 (NOTE: THIS IS A STANDARD LEGEND AND NOT ALL SYMBOLS ARE NECESSARILY USED.) X PC T F J J J G D X 3 SMOKE DETECTOR PHOTO ELECTRIC M SMOKE DETECTOR MULTI SENSOR TECHNOLOGY BR SMOKE DETECTOR BEAM RECEIVER BT SMOKE DETECTOR BEAM TRANSMITTER HEAT DETECTOR RATE OF RISE 135°HEAT DETECTOR FIXED TEMPERATURE ASNOTED LINE TYPE HEAT SENSITIVE CABLE DETECTOR SMOKE DETECTOR DUCT MOUNTED FIRE ALARM CONTROLLED MAGNETIC DOOR HOLDER / RELEASE FIRE ALARM HORN FIRE ALARM STROBE FIRE ALARM COMBINATION HORN/STROBE P FIRE ALARM PULL STATION DUCT SMOKE DETECTOR REMOTE MONITOR/TEST STATION TV ALARM STROBE MULTIPLE STATION 120VAC SMOKE AND CARBON MONOXIDE ALARM MULTIPLE STATION 120VAC/12VDC SMOKE ALARM MULTIPLE STATION 120VAC/12VDC DC INTRUSION DETECTION DOOR CONTACT MS INTRUSION DETECTION MOTION SENSOR GB INTRUSION DETECTION GLASSBREAK SENSOR KP INTRUSION DETECTION KEYPAD S INTRUSION DETECTION ALARM SIREN 26 05 00 COMMON WORK REQUIREMENTS FOR ELECTRICAL: ALL ELECTRICAL WORK SHALLBE INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE, STATE, MUNICIPAL, FEDERAL LAWS, AND AMENDMENTS GOVERNING THE PROJECT. ALL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A CERTIFIED ADMINISTRATOR JOURNEYMAN ELECTRICIAN. CONTRACTOR SHALL SUBMIT REQUEST FOR SUBSTITUTION IN WRITING TO THE ENGINEER. THE CONTRACTORSHALL OBTAIN ALL REQUIRED CONSTRUCTION PERMITS ANDPAY ALL ASSOCIATED FEES. MATERIALS AND EQUIPMENT SHALL BE NEW COMMERCIAL GRADE ANDACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION AS SUITABLE FOR THE USE INTENDED. ALL ELECTRICAL EQUIPMENT SHALL INCLUDE THE SEAL OF A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE PURPOSE FOR WHICH IT IS INSTALLED. THE CONTRACTOR IS REQUIRED TO COORDINATE THE MINIMUM WORKING CLEARANCES REQUIREDBY THE NATIONAL ELECTRICAL CODE 110.26. THE CONTRACTOR ISREQUIRED TO COORDINATE WITH ALL SUBCONTRACTORS SO THAT ENCROACHMENTS INTO THIS RESTRICTED SPACE ARE PREVENTED. ALL CABLING, RACEWAYS, CABLE TIESAND COMPONENTS LOCATED IN CEILING SPACES THAT ARE PLENUMS SHALL BE PLENUM RATED. PENETRATIONS OF FIRE BARRIERS: ALL ELECTRICALPENETRATIONS THROUGH FIRE RATED BARRIERS SHALL BE SEALED IN ACCORDANCE WITH NEC ARTICLE 300.21. ACCESS PANELS: PROVIDE ACCESS PANELS FOR ALL LOCATIONS NECESSARY TO ACCESS ELECTRICAL EQUIPMENT AND JUNCTION BOXES. ACCESS PANELS SHALL BE FIRE RATEDEQUAL TOOR EXCEEDING THE ADJACENT WALL OR CEILING CONSTRUCTION AND PAINTED TO MATCH. SEISMIC: CONTRACTOR TO PROVIDE DEFERRED SUBMITTAL FOR SEISMIC ANCHORING DESIGN FOR ALLEQUIPMENT OVER 300 POUNDS. 26 05 19 POWER CONDUCTORS: ALL POWER AND CONTROL CONDUCTORS SHALLBE COPPER UNLESS NOTEDOTHERWISE. ALL CONDUCTORS ROUTEDIN UNHEATED SPACES OF THE BUILDING, UNDERGROUND, OR LOCATED OUTSIDE OF THE BUILDING ARE REQUIRED TO HAVE TYPE XHHW 90 DEGREE C INSULATION. ALL CONDUCTORS LOCATED IN HEATEDSPACES CAN BE XHHW OR THHN 90 DEGREE C INSULATION UNLESS NOTED OTHERWISE. CONDUCTOR AMPACITY SHALL BE BASED ON TABLE 310 16OF THE NEC. USE 60 DEGREE C. RATING COLUMN FOR CIRCUITS TERMINATING ON DEVICES RATEDBELOW 100A. USE 75 DEGREE C RATING COLUMN FOR CIRCUITS TERMINATING ON DEVICES ANDIN ENCLOSURES RATED 100A ANDOVER. 90 DEGREE C. RATING COLUMN CAN BE USED FOR DERATING CALCULATIONS ONLY. PROVIDE UNSHARED DEDICATEDNEUTRAL FOR EACH CIRCUIT. MINIMUM SIZE CONDUCTORS FOR 15 AND 20 AMP BRANCH CIRCUITS MEASURED FROM THE PANELBOARD TOTHE FURTHEST DEVICE ON THE CIRCUIT UNLESS OTHERWISE NOTED ON THE DRAWINGS. 120 VOLT BRANCH CIRCUITS: 12 AWGUP TO 75 FEET. 10 AWG75 FEET TO 120 FEET. 8 AWGGREATER THAN 120 FEET. INSTALL IN ACCORDANCE WITH NEC REQUIREMENTS FOR AMBIENT TEMPERATURE DERATING, CONDUIT FILL DERATINGAND BOX FILL. COLOR CODE CONDUCTORS BLACK, RED, WHITE, AND GREEN FOR 240/120V 1 PHASE 3 WIRE CIRCUITS;BLACK, RED, BLUE, WHITE, AND GREEN FOR 208Y/120V 3 PHASE 4 WIRE CIRCUITS AND BROWN, ORANGE, YELLOW, GRAY FOR ALL 480Y/277V 3 PHASE CIRCUITS. IDENTIFY GROUNDEDCONDUCTORS PER NEC FOR ALLCIRCUITS. 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS: ALL CLASS 1 CIRCUITS SHALL BE INSTALLED IN CONCEALED METALLIC RACEWAY EXCEPT WHERE SPECIFICALLY INDICATED ELSEWHERE INTHE SPECIFICATIONS OR SHOWN ON THE DRAWINGS. CLASS 2 CIRCUITS MAY BE INSTALLED IN CABLE TRAYS OR CAT 5 RATED J HOOKS SPACED NO MORE THAN 4 FT APART WHERE NO CABLE TRAY ISDENOTED. WHERE WIRING OR CABLING IS ROUTED IN NON ACCESSIBLE LOCATION, A RACEWAY SYSTEM IS TO BE PROVIDED. BELOW GRADE: PVC, HDPE OR RMC (RMC MUST BE USEDFOR 90 DEGREE BENDS AND STUB UPS). EXPOSED INTERIOR: RMC, IMC, OR EMT. CONCEALED INTERIOR: RMC, IMC, OR EMT. MC IS ACCEPTABLE FOR LOCAL BRANCH CIRCUITING, BUT ALL HOME RUNS SHALL BE INSTALLED IN CONDUIT. HAZARDOUS CLASSIFIED WIRING: RMC OR MC HL. (CONDUIT SEALS PER NEC REQUIREMENTS). EXPOSED TO PHYSICAL DAMAGE (INSTALLED EXPOSED BELOW 8 FT): RMC. ALSO PROVIDE RMC FOR ALL PENETRATIONS AND STUB UPS FROM CONCRETE STRUCTURES ANDFLOORS. PROVIDE 10 FT MINIMUM STUB OUT FROM UNDERGROUND LIGHT POLE BASES. MAKE CONNECTIONS TO MOTORS, TRANSFORMERS AND OTHER EQUIPMENT WITH FLEXIBLE METAL CONDUIT (FMC) OF GALVANIZED STEEL. USE FITTINGS LISTED FOR USE WITH FLEXIBLE METAL CONDUIT OF ELECTRO ZINC GALVANIZEDMALLEABLE IRONOR STEEL CONSTRUCTION. USE LIQUID TIGHT FLEXIBLE CONDUIT FOR ALL FLEXIBLE EXTERIOR LOCATIONS, WET LOCATIONS AND CONNECTIONS TO PUMPS. CONCEAL ALL ELECTRICAL RACEWAYS, BOXES, CABLING, CONDUCTORS AND THE LIKE IN WALLS, BELOW FLOORS, SLABS OR ABOVE FINISHED CEILING SPACES. ELECTRICAL EQUIPMENT AND WIRING CAN BE EXPOSED IN MECHANICAL ROOMS, TELECOMMUNICATIONROOMS OR WHERE SPECIFICALLY NOTED. DO NOT ROUTE RACEWAYS ON THE EXTERIOR SURFACE OF THE BUILDING OR THE ROOF UNLESS SPECIFICALLY NOTED OTHERWISE. PROVIDE ALL WIRING AND EQUIPMENT IN ELEVATOR PITS, WET OR EXTERIOR LOCATIONS USING EQUIPMENT ANDWIRING METHODS RATED FOR WET ENVIRONMENTS. BOXES: PROVIDE PULL AND JUNCTION BOXES AS REQUIRED PER NEC REQUIREMENTS RATEDFOR THE ENVIRONMENT INSTALLED. BRANCH CIRCUIT JUNCTIONBOXES TO BE ELECTRO GALVANIZED, 4"SQUARE BY 1 1/2" DEEP MINIMUM FOR USE IN INTERIORAREAS. PROVIDE 4 11/16" SQUARE BY 2 1/8" DEEP OUTLET BOXES FOR ALLVOICE AND DATA OUTLETS. DO NOT INSTALL BOXES BACK TO BACK IN WALLS. PROVIDE SEPARATIONTO MINIMIZESOUND TRANSFER. PROVIDE FIRE RATED PADS TO COVER EACH BOX IN FIRE RATED WALLSWHERE NECESSARY TO MAINTAIN FIRE WALLRATING. 26 2416 PANELBOARDS AND SWITCHBOARDS: BRANCH CIRCUIT: PROVIDE ANDINSTALL NEMA PB1; BOLT ON CIRCUIT BREAKER TYPE.FS W P 115; TYPE I, CLASS 1 PANELBOARD OF THE RATING AND CONFIGURATION AS SHOWN ON THE SINGLE LINE DIAGRAM AND PANEL SCHEDULES. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING CIRCUITING ARRANGEMENT. DISTRIBUTION: PROVIDE AND INSTALLI LINE TYPE; CIRCUIT BREAKER TYPE. CLASS 1 PANELBOARD OR SWITCHBOARD OF THE RATING AND CONFIGURATION AS SHOWN ON THE SINGLE LINE DIAGRAMAND PANEL SCHEDULES. COORDINATE AND PROVIDE THE EQUIPMENTWITH THE SHORT CIRCUIT CURRENT RATING (SCCR) FOR THE AVAILABLE FAULT CURRENT AT THE POINT OF THE SYSTEM WHERE INSTALLED. 26 2713 ELECTRICAL SERVICES: THE ELECTRICAL CONTRACTOR SHALL CONTACT EACH SERVING UTILITY CO. AND VERIFY EXACT SERVICE REQUIREMENTS FOR POWER, TELEPHONE AND CABLE TV. THE CONTRACTOR SHALL COORDINATE AND PROVIDE ALL REQUIREMENTS OF EACH SERVING UTILITY ANDALL EQUIPMENT SHALL CONFORM TO THE SERVING UTILITY STANDARDS ANDREQUIREMENTS. 26 51 00 LIGHTING EQUIPMENT: PROVIDE AND INSTALL ALL LIGHTING EQUIPMENT AS SHOWN ON THE DRAWINGS AND DESCRIBEDIN THE LIGHTING FIXTURE SCHEDULE. PROVIDE FLUORESCENT FIXTURES WITH RAPID START, CLASS P, CONSTANT WATTAGE, ELECTRONIC BALLASTS. BALLASTS SHALL BE SOUND RATED A. EXTERIOR FIXTURES SHALL BE RATEDFOR OPERATION AT LEAST 20 DEG F. CONNECT ALL EMERGENCY LIGHTING UNITSAND MODULES TO THE LOCAL AREA LIGHTING CIRCUITS AHEAD OF ANY SWITCHES OR RELAYS. LOCATE REMOTE TEST SWITCHES ANDINDICATOR LIGHTS AS NECESSARY FOR TEST SWITCHES ON EMERGENCY MODULES. GENERAL REQUIREMENTS SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E0.1 ELECTRICAL LEGEND & GENERAL REQUIREMENTS EIC JOB NO: E13 2002 7-11-2014 ABBREVIATIONS (D) DEMOLISH (E) EXISTING (N) NEW (R) RELOCATED A AMPERES AC ABOVE COUNTER AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AIC AMPS INTERRUPTING CAPACITY C CONDUIT OR CELCIUS CAT CATEGORY CB CIRCUIT BREAKER CO, C.O. CONDUIT ONLY CT CURRENT TRANSFORMER DISC DISCONNECT EGC EQUIPMENT GROUNDING CONDUCTOR ERCSP ELEVATORRECALL CONTROL AND SUPERVISORY PANEL F FARENHEIT FAA FIRE ALARM ANNUCIATOR FACP FIREALARM CONTROL PANEL FHP FRACTIONAL HORSEPOWER FLA FULL LOAD AMPS FSD FIRE SMOKE DAMPER FT FEET FU FUSE G, GFCI GROUND FAULT CIRCUIT INTERRUPTER GEC GROUNDINGELECTRODE CONDUCTOR GFEP GROUND FAULT EQUIPMENT PROTECTION HP HORSEPOWER ID IDENTIFICATION IN INCHES KVA KILOVOLT AMPERE KW KILOWATT LRA LOCKED ROTOR AMPS LTG LIGHTING MCA MINIMUM CIRCUIT AMPACITY MDP MAIN DISTRIBUTION PANEL MDS MAIN DISTRIBUTION SWITCHBOARD MFS MAXIMUM FUSE SIZE NC NORMALLY CLOSED NO NORMALLY OPEN P POLES PC PHOTOCELL PH,Ø PHASE PNL PANEL PRI PRIMARY REC RECEPTACLE RIB RELAY IN A BOX (MOTOR RATED) SCCR SHORT CIRCUIT CURRENT RATING SE SERVICE ENTRANCE RATED SEC SECONDARY SSEBJ SUPPLY SIDE EQUIPMENT BONDINGJUMPER SVC SERVICE TELECOM TELECOMMUNICATION TGB TELECOMMUNICATION GROUNDING BUSBAR TMGB TELECOMMUNICATION MAIN GROUNDING BUSBAR TYP TYPICAL UON UNLESS OTHERWISE NOTED V VOLTS VA VOLTS AMPERES VFD VARIABLE FREQUENCY DRIVE W WATTS OR WIRE WG WIRE GUARD WP WEATHERPROOF(NEMA 4 RATED) XFMR TRANSFORMER ELECTRICAL SHEET LIST NUM SHEET TITLE E0.1 ELECTRICAL LEGEND & GENERAL REQUIREMENTS E0.2 ELECTRICAL SCHEDULES E1.1 ELECTRICAL SITE PLAN E2.1 ELECTRICAL LIGHTING PLAN E3.1 ELECTRICAL POWER & SIGNAL PLAN E3.2 ROOF POWER & SIGNAL PLAN E4.1 ELECTRICAL DIAGRAMS & DETAILS E4.2 ELECTRICAL DIAGRAMS & DETAILS E5.1 ELECTRICAL PANEL SCHEDULES Grand total: 9 MOUNTING HEIGHT SCHEDULE EQUIPMENT HEIGHT PANELBOARDS (TOP) 72" SPECIAL SYSTEM PANELS (TOP) 72" POWER METER BASE (CENTER LINE OF SOCKET) PER UTILITY CONTACTORS, MOTOR STARTERS, DISCONNECT SWITCHES (TOP) 66" RECEPTACLES IN OFFICE AREAS 18" RECEPTACLES LOCATED IN HAZARDOUS OR S 2 OCCUPANCIES 24" MINIMUM RECEPTACLES IN NON FINISHED ANDMECHANICAL SPACES 46" ABOVE COUNTER DEVICES (DENOTED "AC" OR BY SYMBOL) SEE NOTES WALL MOUNTED SWITCHES 46" TELECOMMUNICATION OUTLETS (WALL MOUNTED DENOTED "W") 18" (WALL MOUNTED 54") CLOCK OUTLETS (BOTTOM) 80" HORNS/STROBES/HORN STROBES/DOORBELL RINGER (BOTTOM) 80" PULL STATIONS, PUSH BUTTONS, DOORBELL PUSHBUTTON 46" NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E0.2 ELECTRICAL SCHEDULES EIC JOB NO: E13 2002 7-11-2014 LUMINAIRE SCHEDULE NOTES REF NOTE 'KEY' '(x)' DENOTES A GENERAL, NON REFERENCED, NOTE. NUMBERED NOTES ARE REFERENCEDFROM THE LUMINAIRE SCHEDULE. (A) QUANTITIES/COUNTS SHOWN IN SCHEDULES ARE FOR CONVENIENCE ONLY. CONTRACTOR TO VERIFY ALL QUANTITIES/COUNTS FROM PLANS. (B) CATALOG NUMBERS ARE FOR GENERAL REFERENCE AND ARE NOT INCLUSIVE OF ALL OPTIONS OR REQUIREMENTS DENOTED ON PLANS AND SPECIFICATIONS. (C) REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND PROVIDE MOUNTING HARDWARE/FLANGES ETC FOR ALL LUMINAIRES FOR CEILING TYPES SHOWN. (D) ALL FLUORESCENT BALLASTS TO BE ELECTRONIC. (E) ALL FLUORESCENTLAMPS TO BE 3500K. (F) PROVIDE ROUGH SERVICE LAMPS FOR ALL INCANDESCENT LUMINAIRES. (G) LUMINAIRES NOTEDON THE FLOOR PLANS AS 'NL' (NIGHTLIGHT) SHALL BE CONNECTED TOUNSWITCHED POWER CIRCUIT NOTED ON DRAWINGS. 1 COORDINATE LUMINAIRE FINISH/COLOR WITH ARCHITECTURAL. 2 PROVIDE CANOPY, ELECTRIC TRANSFORMER, CONNECTORS, AND MOUNTING HARDWARE AS NECESSARY FOR A COMPLETE INSTALLATION. 3 PROVIDE WITH FIELD CUTABLE AIRCRAFT CABLE MOUNTS. COORDINATE EXACT MOUNTING HEIGHT WITH ARCHITECTURAL. MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES REF NOTE 'KEY' '(x)' DENOTES A GENERAL, NON REFERENCED, NOTE. NUMBERED NOTES ARE REFERENCED FROM THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. (A) QUANTITIES/COUNTS SHOWN IN SCHEDULES ARE FOR CONVENIENCE ONLY. CONTRACTOR TO VERIFY ALL QUANTITIES/COUNTS FROM PLANS. (B) REFER TO FLOOR PLAN DRAWINGS FOR EQUIPMENT TYPE REQUIREMENTS, LOCATIONS AND QUANTITIES. (C) COORDINATE ALL CONNECTION REQUIREMENTS WITH MECHANICAL AND ACTUAL EQUIPMENT SUPPLIEDPRIOR TO ROUGH IN. 1 PLUG ANDCORD CONNECTION. 2 PROVIDE INTERCONNECTION WIRING BETWEEN CU 1 AND CRU 1 AS NECESSARY. COORDINATE REQUIREMENTS WITH MECHANICAL. 3 PROVIDE HP RATEDRELAY IN A BOX (RIB) AS NECESSARY FOR MOTOR CONTROL. COORDINATE ALL CONTROL REQUIREMENTS WITH MECHANICAL. MECHANICAL EQUIPMENT CONNECTION SCHEDULE QTY EQUIP ID LOCATION OR FUNCTION KVA HP FLA MCA MFS V PH FEEDER NOTES 1 AC 1 AIR COMPRESSOR 3.536 3.7 15 208 1 1/2"C, (2)10 AWG, (1)10 AWG EGC 1 B 1 BOILER 1.500 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 1 CP 1 BOILER CIRCULATIONPUMP 1.260 3/4 208 3 1/2"C, (3)12 AWG, (1)12 AWG EGC 1 CP 2 HEADER CIRCULATION PUMP 1.260 3/4 208 3 1/2"C, (3)12 AWG, (1)12 AWG EGC 1 CP 3 HWG 1 CIRCULATION PUMP 0.528 1/6 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 3 1 CP 4 HEATING CIRCULATION PUMP 1.260 3/4 208 3 1/2"C, (3)12 AWG, (1)12 AWG EGC 1 CP 5 HOT WATER RE CIRCULATION PUMP 0.192 1/25 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 3 1 CRU 1 COMPUTER ROOM AC EVAPORATOR UNIT 0.208 1 208 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 2 1 CU 1 COMPUTER ROOM AC CONDENSING UNIT 2.496 12 15 208 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 2 1 CUH 1 CABINET UNIT HEATER 0.120 FHP 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 1 EF 1 EXHAUST FAN 0.528 1/6 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 3 1 GMT 1 GLYCOL MAKE UP TANK 0.360 FHP 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 1 1 RTU 1 ROOF TOP UNIT 13.080 36.3 45 208 3 SEE ONE LINE DIAGRAM 1 UH 1 UNIT HEATER 0.064 FHP 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC 1 UH 2 UNIT HEATER 0.192 1/20 120 1 1/2"C, (2)12 AWG, (1)12 AWG EGC LUMINAIRE SCHEDULE QTY TYPE DESCRIPTION WATTS LAMPS MOUNTING MANUFACTURER MODEL NOTES 10 CF1 4FT FLUORESCENT STRIP 34 (1) 28W T5 SOFFIT SURFACE LITHONIA Z 1 28 MVOLT GEB10PS 4 CF1H 4FT HIGH OUTPUT FLUORESCENT STRIP 60 (1) 54W T5HO SOFFIT SURFACE LITHONIA Z 1 54T5HO MVOLT GEB10PS 4 CF2H 8FT HIGH OUTPUT FLUORESCENT STRIP 120 (2) 54W T5HO CEILING/SURFACE LITHONIA TZ 1 54T5HO MVOLT GEB10PS 11 DL4 4" LEDDOWNLIGHT W/ OPEN REFLECTOR 21 LED CEILING RECESSED GOTHAM EVO 35/10 4AR MVOLT 16 DL4D 4" LED DOWNLIGHT W/ OPEN REFLECTOR & 0 10V DIMMINGDRIVER 21 LED CEILING RECESSED GOTHAM EVO 35/10 4AR MVOLT 7 E1 LED EMERGENCY LIGHTING UNIT W/ TWO ADJUSTABLE HEADS 1 LED WALL +7'0" OR CEILING LITHONIA ELM2 LED 4 ERL LED EMERGENCY REMOTE HEAD W/ EXTERIOR RATING 2 LED WALL ABOVE DOOR LITHONIA ELA QWP L039 13 GR2 2' X 4' VOLUMETRIC TROFFER 60 (2) 28W T5 CEILING GRID LITHONIA 2RT5 28T5 MVOLT GEB95 8 GR2D 2' X 4' VOLUMETRIC TROFFER W/ STEP DIMMING BALLAST 60 (2) 28W T5 CEILING GRID LITHONIA 2RT5 28T5 MVOLT GEB95S 1 LB2 LOW PROFILE ARCHITECTURAL WRAP W/ PRISMATIC LENS 58 (2) 28W T5 CEILING/SURFACE LITHONIA LB 2 28T5 MVOLT GEB10PS 4 LB3 LOW PROFILE ARCHITECTURAL WRAP W/ PRISMATIC LENS 88 (3) 28W T5 CEILING/SURFACE LITHONIA LB 3 28T5 MVOLT GEB10PS 43 SF2 ARCHITECTURAL SUSPENDED DIRECT/INDIRECT FLUORESCENT 70 (2) 28W T5 CEILING SUSPENDED PINNACLE EX3B A 0 T5 1 1 4 120 1,3 1 T1 LOW VOLTAGE MONORAIL TRACK LIGHTING W/ ADJUSTABLE SPOT HEADS 150 (1) 50W MR16 MAX PER HEAD CEILING SURFACE TECH LIGHTING 700MOA 96 S TRACK & (3) EACH #700MO SPT6 06 S HEADS 2 2 WF1 2FT ARCHITECTURAL FLUORESCENT WALL MOUNT VANITY LIGHT 30 (1) 24W T5HO WALL ABOVE MIRROR EUREKA 3530 23 F.T5.24 120 SC WH 7 WF2 4FT ARCHITECTURAL FLUORESCENT WALL MOUNT DIRECT/INDIRECT 58 (2) 28W T5 WALL +8'6" PINNACLE EX3B A 0 T5 1 1 4 WA 120 1 3 X LED EXIT SIGN W/ BATTERY BACKUP 1 GREEN LED WALL OR CEILING LITHONIA LQM S W 3 G 120/277 ELN 2 XE LED COMBO EXIT SIGN & EMERGENCY LIGHTINGUNIT W/ BATTERY BACKUP 3 GREEN LED WALL OR CEILING LITHONIA LHQM LED G 4 XER LED COMBO EXIT SIGN & EMERGENCY LIGHTING UNIT W/ BATTERY BACKUP & CAPACITY TO POWER REMOTE HEAD 3 GREEN LED WALL OR CEILING LITHONIA LHQM LED G HO 4 ZDL6 6" LED DOWNLIGHT W/ WET LABEL 20 LED CEILINGRECESSED KIRLIN LRR 06018 41K 5 ZW1 WALL MOUNTED LED AREA LIGHT W/ FORWARD THROW DISTRIBUTION & CUTOFF OPTICS 14 LED WALL +8'6" LITHONIA DSXW1 LED 10C 350 40K TFTM MVOLT 1 3 ZW2 WALL MOUNTED LED AREA LIGHT W/ TYPE II DISTRIBUTION & CUTOFF OPTICS 14 LED WALL +8'6" LITHONIA DSXW1 LED 10C 350 40K T2S MVOLT 1 1 NO. DATE 1 06-30-14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands ELECTRICAL SERVICE EQUIPMENT T PROPOSEDHEA SERVICE TRANSFORMER UNDERGROUND SERVICE LATERAL 1 2 TTB SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E1.1 ELECTRICAL SITE PLAN EIC JOB NO: E13 2002 7-11-2014 SCALE:1" = 10'0"E1.1 1 ELECTRICAL SITE PLAN SHEET NOTES 1 CONTRACTORTO COORDINATE EXACT POWER SERVICE TRANSFORMER LOCATION WITH UTILITY. 2 PROVIDE CONDUIT(S) FROM TELECOM TERMINATIONS BACKBOARD (TTB) STUBBED OUT TO PROPERTY LINE FOR FOR TELECOM SERVICE. CONTRACTOR TO COORDINATE EXACT CONDUIT SIZE, QUANTITY, ROUTING, AND REQUIREMENTS WITH UTILITY. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FD FD FD FD FD FD 3 3 3 3 3 3 3 3 A C G 8 521 H B E F 7634 D F2 4.1 108 CONFERENCE ROOM 103ADMIN HALL 109 ELECTRICAL/IT ROOM 110 HARBOR MASTER OFFICE 111 ADMIN STORAGE 112 ADMIN OPEN OFFICE 114OPERATIONS 115 DEPUTY HARBORMASTER OFFICE 116 MULTI PURPOSE BREAK ROOM 118PRIVATE HALL 120 MECHANICAL ROOM 117STORAGE 119 MEETING ROOM 121LOCKER ROOM 123 SHOP/GARAGE 122 UNISEX RESTROOM 101 ARCTIC ENTRY 106 MEN'S R.R. 105 WOMEN'S R.R. 102 ENTRY HALL 104LOBBY 107JANITOR A 2eDL4DA2eDL4DA2eDL4DA2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2eDL4D A 2cSF2 A 6fGR2 A 6fGR2 A 4LB3A4LB3 A 4GR2D A 4GR2D A 4GR2D A 4GR2D A 4SF2 A 10hSF2 A 10hSF2 A 10hSF2 A 10hSF2 A 10hSF2 B 6zSF2 B 6zSF2 B 6zSF2 B 6zSF2 A 8gSF2 A 8gSF2 A 6LB2 A 14DL4 A 12DL4 A 12DL4 B 4GR2D B 4GR2D B 4GR2D B 4GR2D B 4GR2 B 4GR2 B 4GR2 B 4GR2 B 6xGR2 B 10LB3 B 10LB3 B 8GR2B8GR2 B 8GR2 B 8CF2H B 8CF2H B 8CF2H B 8CF2H A 12wWF2 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 2dCF1 A 8gSF2 A 8gSF2 A 8gSF2 A 8gSF2 A 12XE A 12XER A 2cSF2 A 2cSF2 A 4SF2 A 10hSF2 A 10hSF2 A 10hSF2 A 10hSF2 B 6zSF2 B 6zSF2 B 6zSF2 B 6zSF2 B 6X B 6XER B 6xGR2 B 6zSF2 B 6zSF2 B 8XE B 8XER A 6XER A 6X A 12X A 8gSF2 A 12wWF2 A 8gSF2 A 8gSF2 A 8gSF2 A 8gSF2 A 8gSF2 A 8gSF2A8gSF2 A 8gSF2 A 8gSF2 A 8gSF2 A 8gSF2 A 8SF2 A 10hSF2 A 6fWF2 B 6xGR2 B 6yDL4 B 6yDL4 B 6yDL4 B 6yDL4 ERL ERL ERL ERLB6E1 B 6E1 A 8E1 A 10E1 A 12E1 A 6E1 B 6E1 B 6zWF2 B 6zWF2 A 10hWF2 A 10hWF2 a b 1 ab 1 2 2 2 2 2 B 2DL4 B 2DL4 B 2WF1 B 2DL4 A 20ZW1 A 20ZW2 A 20ZW2 A 20ZW2 A 20ZW1 A 20ZW1 A 20ZW1 A 18ZDL6 A 18ZDL6 A 18ZDL6 A 18ZDL6 3 3 3 3 3 3 3 A 12wT1 113 PRINTER ALCOVE edc w w y x yz z 124 WASH DOWN PATIO x z f f g h g h 3 3 3 3 A 16CF1H A 16WF1 A 16CF1H A 14CF1H A 14CF1H A 14DL4 A 20ZW13 PNL 'A' PNL 'B' LIGHTING CONTACTOR 'LC 1' A 6fGR2 1 SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E2.1 ELECTRICAL LIGHTING PLAN EIC JOB NO: E13 2002 7-11-2014 SHEET NOTES 1 PROVIDE MULTI LEVEL SWITCHING. SWITCHES 'a' AND 'b' CONTROL STEP DIMMING BALLAST IN EACH TYPE 'GR2D' LUMINAIRE FOR 0 50 100% LIGHTING CONTROL. SCALE:3/16" = 1'0"E2.1 1 LIGHTING PLAN 2 PROVIDE WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. 3 LUMINAIRE CONTROLLED BY PHOTOCELL THRU LIGHTING CONTACTOR 'LC 1'. SEE 4/E4.1 FOR DETAIL. NO. DATE 1 06-30-14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FD FD FD FD FD FD J T T J J J J DC DCMS MS MS FD T TTT A C G 8 521 H B E F 7634 D F2 4.1 108 CONFERENCE ROOM 103ADMIN HALL 109 ELECTRICAL/IT ROOM 110 HARBOR MASTER OFFICE 111 ADMIN STORAGE 112 ADMIN OPEN OFFICE 114OPERATIONS 115 DEPUTY HARBORMASTER OFFICE 116 MULTI PURPOSE BREAK ROOM 118 PRIVATE HALL 120 MECHANICAL ROOM 117 STORAGE 119 MEETING ROOM 121 LOCKER ROOM 123 SHOP/GARAGE 122 UNISEX RESTROOM 101ARCTIC ENTRY 106MEN'S R.R. 105WOMEN'S R.R. 102ENTRY HALL 104LOBBY 107 JANITOR G +48" G +24" G +48" G B 17 REFRIGERATOR G +48"G B 19 COFFEE MAKER G G B 23 MICROWAVE G G B 25 MICROWAVE G G WP G +30" G G G A 5 COFFEE MAKER A 7 U/C REFRIGERATOR WP G+18" WP G +18" WP G+30" WP G +30" B 9 RADIO EQUIPMENT B 35 UH 2 E3.1 2 E3.1 3 METER BASE CT ENCLOSURE SERVICE DISCONNECT A 17 CUH 1 1 4 42 +48" 3 3 B 36,38 ELECTRIC DRYER +48" B 34 WASHER +24" +24" A 1 B 40,42 AC 1 B 31 B 31 B 33 B 31 B 2 B 37 B 37 B 21 B 21 B 7 B 5 B 5 B 5 B 5 B 3 B 3 B 1 B 7 B 1 B 1 B 1 B 1 B 7B1 A 25 A 25 A 19 A 21 A 21 A 15 A 15 A 15 A 17 A 33 A 33 A 1A1 A 1 A 1 A 3 A 3 A 9 A 9 A 9A9 A 9 A 13 A 14 A 16A13 A 11 A 11 A 11 A 11 A 13 A 19 A 23 A 23 A 25 A 27 A 29 A 27 A 27 A 29 A 27 B 11 B 13 B 15 B 11 B 13 B 15 B 11 B 13 B 15 B 11 +24" B 29 B 29 B 29 A 16 A 14 G B 27 DISPOSAL B 3 A 15 1 124 WASH DOWN PATIO 6 A 32,34 CU 1 G G G G B 35 B 35 B 35 B 35 WP +24" A 227 WP G WP +24" A 35 A 41 A 41 5 5 PANIC BUTTON PANIC BUTTON 8 8 A 9 A 14G +48" A 31 COPIER/PRINTERA29 S WP S WP S S D PNL 'MDP'PNL 'A'PNL 'B'TTB A 24 INTRUSION DETECTION PANEL A 40,42 TELECOM RACK A 36,38 TELECOM RACK A 37 A 39 A 39 6 CRU 1 LIGHTING CONTACTOR 'LC 1' 109 ELECTRICAL/IT ROOM A 26 FIRE ALARM PANEL E B 10 EF 1 B 14 B 1 B 28,30,32 CP 1 B 28,30,32 CP 2 B 16 CP 3 B 28,30,32 CP 4 B 16 CP 5 B 10 UH 1 B 12 GMT 1 G +48 G +48 G +48 B 12 B 12 120 MECHANICAL ROOM SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E3.1 ELECTRICAL POWER & SIGNAL PLAN EIC JOB NO: E13 2002 7-11-2014 SHEET NOTES 1 PROVIDE POWER ANDSIGNAL CONNECTIONS FOR WALL MOUNTED TELEVISION. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH OWNER PRIOR TO ROUGH IN. SCALE:3/16" = 1'0"E3.1 1 POWER AND SIGNAL PLAN SCALE:3/8" = 1'0"E3.1 2 ENLARGED SCALE ELECTRICAL/IT ROOM SCALE:3/8" = 1'0"E3.1 3 ENLARGED SCALE MECHANICAL ROOM 2 PROVIDE 1.25" CONDUIT FROM FLOOR JUNCTION BOX TO WALL BOX AT TV LOCATION FOR ROUTING A/V CABLES. 3 PROVIDE WIREMOLD 6000 SURFACE MOUNT MULT CHANNEL RACEWAY FOR RECEPTACLES AND TELECOM OUTLETS. 4 PROVIDE POWER CONNECTION FOR AUTOMATED PAPER TOWEL DISPENSER. COORDINATE EXACT LOCATION ANDREQUIREMENTS WITH OWNER/ARCHITECTURAL PRIOR TO ROUGH IN. 5 PROVIDE ROUGH IN CONNECTIONS AS NECESSARY FOR FUTURE HANDICAP DOOR OPERATORS ANDPUSHBUTTON CONTROLS. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH ARCHITECTURAL/OWNER PRIOR TO ROUGH IN. 6 PROVIDE INTERCONNECTION WIRING AS NECESSARY FROM CU 1 TO CRU 1. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL. 7 PROVIDE JUNCTION BOX WITH CIRCUIT FOR FUTURE SITE ILLUMINATED SIGN. CONTROL VIA PHOTOCELL THRULIGHTING CONTACTOR 'LC 1'. SEE 4/E4.1 FORDETAIL. CONTRACTORTO PROVIDE TELECOM ROUGH IN ONLY.TELECOM HORIZONTAL CABLING, TERMINATIONS, WALL PLATES, EQUIPMENT RACKS, AND RACK EQUIPMENT TOBE PROVIDEDBY OTHERS UNDERSEPARATE CONTRACT WITHOWNER. ROUGH IN TO INCLUDE TELECOM OUTLET WALL BOXES, CONDUITS TOCEILING SPACE, J HOOKS, CABLE TRAYS, ANDUTILITY CABLE DEMARCATION EQUIPMENT. 8. 8 COORDINATE EXACT LOCATION OF INTRUSION DETECTION SYSTEM PANIC BUTTON WITH OWNER PRIOR TO ROUGH IN. THE INTRUSION DETECTION SYSTEM IS A DESIGN/BUILD COMPONENT OF THE PROJECT. ALL DEVICES SHOWN ON PLANS ARE FOR REFERENCE ONLY AND ARE MEANT TO SHOW SYSTEM FUNCTIONALITY ONLY. SECURITY SYSTEMCONTRACTOR TO DETERMINE EXACT DEVICE PLACEMENT AND REQUIREMENTS BASED ON SYSTEM PROVIDED, DEVICE COVERAGE, AND MANUFACTURER RECOMMENDATIONS. SEE 2/E4.2 FOR SYSTEM DETAIL. 9. THE FIRE ALARM SYSTEM IS A DESIGN/BUILD COMPONENT OF THE PROJECT. CONTRACTORTO PROVIDE SYSTEM SHOP DRAWINGSTO STATE FIRE MARSHAL FOR APPROVAL. SEE 1/E4.2 FOR SYSTEM DETAIL. 10. 2 NO. DATE 2 07-11-14 CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands A C G 8 521 H B E F 7634 D F2 4.1 MDP 13,15,17 RTU 1 G WP +24" B 39 WP G WP +24" B 39 1 SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E3.2 ROOF POWER & SIGNAL PLAN EIC JOB NO: E13 2002 7-11-2014 SCALE:3/16" = 1'0"E3.2 1 ROOF POWER AND SIGNAL PLAN SHEET NOTES 1 MOUNT RECEPTACLES TO EITHER SIDE OF ROOF TOP UNIT. COORDINATE EXACT LOCATION WITH ROOF TOP UNIT ACCESS PANELS. NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 1,3,5 240320 PACAB Work Session Laydown-Uplands PANEL 'A' 150/3 150/3 45/3 100/3 RTU 1 WP PANEL 'MDP' 400A M (2)4" C.O. CT ENCLOSURE NEMA 3R METER BASE NEMA 3R HEA POWER SERVICE: 208Y/120V, 3 PHASE, 4 WIRE N G 400 4A SERVICE DISCONNECT SE RATED NEMA 3R 400 4B PANEL 'B' 150 4A 150 4A 100/3 100/3 45 3A SPACE SPACE SPACE FEEDER SCHEDULE TAG COPPER OPTIONAL ALUMINUM NOTES 45 3A 1"C, (3)6 AWG, (1)10 AWG EGC N/A 150 4A 2"C, (4)1/0 AWG, (1)6 AWG EGC 2"C, (4)3/0 AWG, (1)4 AWG EGC 400 4A 2EA: 2"C, (4)3/0 AWG, (1)1/0 AWG SSEBJ 2EA: 2.5"C, (4)250 KCMIL, (1)3/0 AWG SSEBJ 400 4B 2EA: 2"C, (4)3/0 AWG, (1)2 AWG EGC 2EA: 2.5"C, (4)250 KCMIL, (1)1 AWG EGC STANDARD NOTES A) ALUMINUM CONDUCTORS MAY BE USED IN LIEU OF COPPER IF ACCEPTABLE TO OWNER. REFERENCED NOTES 1) NOT USED. SERVICE NEUTRAL NEUTRAL BUS GROUND BUS SERVICE DISCONNECT MAIN BONDING JUMPER, 1/0 AWG (NOTE: DO NOT BOND NEUTRAL TO GROUNDAT ANY OTHER POINT IN THE SYSTEM, U.O.N) EQUIPMENT BONDING JUMPER, 1/0 AWG GAS PIPING(TYP) WATER METER, VALVE OR DISCONTINUITY 10' MINIMUM CONCRETE ENCASED ELECTRODE (UFER) 25' 4 AWG MIN. BARE COPPER IN CONCRETE FOOTING 2" COVER BUILDING STEEL TO TELECOMMUNICATIONS TERMINATION BACKBOARD (TTB) DETAIL NOTES: 1. ALL CONDUCTOR SIZES SHOWN ARE COPPER. 2. BOND ALL PIPING ANDBUILDING DISCONTINUITIES TO PROVIDE ELECTRICALLY CONTINUOUS SYSTEM. PROVIDE BOND JUMPER EQUAL TO GROUNDING ELECTRODE CONDUCTORFOR THAT SYSTEM. 3. PROVIDE RACEWAY FOR ALL CONDUCTORS. RACEWAY TO BE METALLIC IN PLENUM AIRSPACES. WHERE METALLIC RACEWAY IS USED, BOND EACH END TO CONDUCTOR. 6 AWG 1/0 AWG 1/0 AWG 6 AWG MIN. EXTERIOR DRIVEN GROUND ROD3/4" X 8'0" (TYP OF 2) (MAY BE OMITTEDWITH CITY INSPECTOR APPROVAL) CT ENCLOSURE SUPPLY SIDE EQUIPMENT BONDING JUMPER (SSEBJ), 1/0 AWG TELECOM SERVICE CONDUIT(S) UTILITY CABLE TELEPHONE PROTECTOR 6 AWG GROUND CONDUCTOR, TYPICAL. 66 PUNCH DOWN BLOCKS 6 AWG CU GROUNDCONDUCTOR TO MAIN POWER SERVICE GROUND BUS TELECOM TERMINATION BACKBOARD (TTB) HORIZONTAL MODULAR PATCH PANEL VOICE MODULAR PATCH PANEL FLOORMOUNTED EQUIPMENT RACK 25 PAIR CAT3 CABLE 4'X8' PLYWOOD BACKBOARD TELECOMMUNICATIONS MAIN GROUND BUSBAR (TMGB) NOTES: 1. ALL CABLING LOCATED IN PLENUM CEILING SPACES SHALL BE PLENUM RATED. 2. PROVIDE INSULATED STRANDED COPPER GROUNDING/BONDING CONDUCTORS. 3. PROVIDE CONDUIT RACEWAYS FOR ALL GROUND/BONDING CONDUCTORS LONGER THAN 6 FEET. 4. BOND ALL TELECOM CONDUITS, CABLE TRAY, EQUIPMENT RACKS, ETC. 5. DIAGRAM SHOWN IS FOR TYPICAL INSTALLATION. CONTRACTOR TO COORDINATE EXACT REQUIREMENTS WITH OWNER. DATA MODULAR PATCH PANEL DATA EQUIPMENT (BY OWNER) HORIZONTALCABLING: (2)CAT6 4 PAIR CABLES, TYPICAL TYPICAL TELECOM OUTLET 3/4"CONDUIT STUB TO ACCESSIBLE CEILING SPACE PROVIDE J HOOK OR CONDUIT SUPPORT IN CEILING SPACE, TYPICAL. PHONE SWITCH (BY OWNER) DATA SWITCH (BY OWNER) QUAD RECEPTACLE, SEE POWER PLAN FOR CIRCUIT NUMBER. C PC TO EXTERIOR & SITE LIGHTING AUTO OFF ON HAND OFF AUTO SWITCH IN COVER OF CONTACTOR ENCL. LABEL SWITCH POSITIONS "AUTO", "ON", "OFF" LIGHTING CONTACTOR 30A, ELECTRICALLY HELD, NEMA 1 ENCLOSURE, 120VCOIL& CONTACTS NN DETAILNOTES 1. CONTACTOR & CONTROLS SHOWN WITHLIGHTING DE ENERGIZED OR "OFF". 2. MOUNT PHOTOCELL ON NORTH SIDE OF BUILDING BELOW ROOF LINE. RED PILOT LIGHT IN COVER PHOTO CELL 22 20/1 20 20/1 18 20/1 PANEL 'A' CIRCUITS SPARE N.O. CONTACT SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E4.1 ELECTRICAL DIAGRAMS & DETAILS EIC JOB NO: E13 2002 7-11-2014 SCALE:NONEE4.1 1 POWER ONE LINE DIAGRAM SCALE:NONEE4.1 2 GROUNDING SYSTEM ONE LINE DIAGRAM SCALE:NONEE4.1 3 TYPICAL TELECOMONE LINE DIAGRAM SCALE:NONEE4.1 4 EXTERIOR LIGHTING CONTACTOR 'LC 1' DIAGRAM NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands FIRE ALARM CONTROL PANEL (ELEC/IT RM) 120V DEDICATED CIRCUIT TOTTB TWO PHONE LINES TYP. INDICATING DEVICES OUTPUT CIRCUITS AS NECESSARY TO ADDITIONAL DEVICES BATTERY BACKUP TYP. MANUAL INITIATING DEVICES TYP. INITIATING DEVICES SPARE INPUT CIRCUIT NOTES: 1.THE FIRE ALARM SYSTEM IS A DESIGN/BUILD COMPONENT OF THIS PROJECT. PROVIDE SHOP DRAWINGS OF SYSTEM DESIGN TO FIRE MARSHAL CERTIFIED BY NICET LEVEL 3 REGISTERED DESIGNER. SEE SPECIFICATIONS FOR MORE DETAIL. 2.INTERLOCK AIR HANDLINGUNITS >2000 CFMWITH DUCT SMOKE DETECTORS TO SHUT DOWN THE UNIT UPON DETECTION OF SMOKE. 3.ALLOW 25% SPARE CAPACITY IN EACH INPUT AND OUTPUT DEVICE CIRCUIT. 4.PROVIDE ADDRESSABLE RELAYS AS NECESSARY TO CLOSE SMOKE FIRE DAMPERS UPON SYSTEM ALARM. 5.PROVIDE 100% FUNCTIONALTEST UPON COMPLETION OF THE SYSTEM INSTALLATION PER NFPA REQUIREMENTS. 6.PROVIDE REMOTE TEXT ANNUNCIATOR AT MAIN ENTRY. 7.PROVIDE TWO PHONE LINES. AUTOMATIC DIALER REMOTE ANNUCIATOR (MAIN ENTRY) P P TYP.DOOR HOLDERS SPRINKLER FLOW AND TAMPER SWITCHES SPRINKLER FLOW BELL INTRUSION DETECTION SYSTEM CONTROL PANEL (ELEC/IT RM) 120V DEDICATED CIRCUIT TO TTB TWO PHONE LINES TO ADDITIONAL DEVICES BATTERY BACKUP TYP. MOTION SENSOR NOTES: 1.THE INTRUSION DETECTION SYSTEMIS A DESIGN/BUILDCOMPONENT OF THIS PROJECT. CONTRACTOR TO PROVIDE SYSTEMWITH FUNCTIONALITY AND DEVICES NOTED. SEE SPECIFICATIONS FOR MORE DETAIL. 2.PROVIDE DOOR CONTACTS, MOTION SENSORS, ANDGLASS BREAK DETECTORS FOR AUTOMATIC INTRUSION DETECTION. 3.ALL DEVICES SHALL BE HARD WIRED. PROVIDE DEDICATED WIRING FOR EACH SENSOR DEVICE. 4.PROVIDE PANIC BUTTONS AT OWNER REQUESTED LOCATIONS. PANIC BUTTONS SHALL MANUALLY INITIATE AN ALARMWHEN ACTIVATED BY BUILDING PERSONNEL. 5.PROVIDE ALARM SIRENS INSIDE BUILDING ANDAT BUILDING EXTERIOR. 6.PROVIDE A CONTROL KEYPAD AT OWNER REQUESTED LOCATION FOR ARMING/DISARMING SYSTEM. 7.PROVIDE SYSTEMPANEL WITH 7 HOUR MINIMUM BATTERY BACKUP. 8.PROVIDE WITH AUTOMATIC DIALER TO CALL MONITORING PERSONNEL IN THE EVENT OF ALARM. PROVIDE TWO PHONE LINES FOR DIALER. 9.PROVIDE SYSTEMWITH CAPABILITY FOR NETWORK INTERFACE ANDREMOTE CONTROL AND MONITORING. 10.PROVIDE 100% FUNCTIONAL TEST UPON COMPLETION OF THE SYSTEM. 11.PROVIDE SPARE ZONE INPUTS FOR FUTURE GROWTH. AUTOMATIC DIALER CONTROL KEYPAD MS S NETWORK INTERFACE FOR REMOTE CONTROL & MONTIORING PANIC BUTTONS TYP. DOOR CONTACT DC TYP. GLASS BREAK SENSOR GB TYPICAL ALARM INITIATING DEVICES SPARE INPUTS FOR FUTURE S TYPICAL ALARM SIRENS SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A E IC E NGINEE RS , INC E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: D C B CONFORMED DRAWING SET E13-2002 EDC BLS BLS 7-11-2014 E4.2 ELECTRICAL DIAGRAMS & DETAILS EIC JOB NO: E13 2002 7-11-2014 SCALE:NONEE4.2 1 TYPICAL FIRE ALARM ONE LINE DIAGRAM SCALE:NONEE4.2 2 TYPICAL INTRUSION DETECTION SYSTEM ONE LINE DIAGRAM NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION 240320 PACAB Work Session Laydown-Uplands SHEET NUMBER SHEET CONTENTS 4321 4321 D C B A D C B A IS S U E D F O R C O N S T R U C T I O N E IC E NGI N EE RS , I N C E L E C T R I C A L E N G I N E E R S 6927 OLD SEWARD HWY SUITE 200 ANCHORAGE, AK 99518 T 907.349.9712 F 907.349.9713 www.eiceng.com DATE: JOB NO: DRAWN: CHECKED: DESIGN BY: REVISIONS: Kl a u d e r & C o m p a n y Ar c h i t e c t s , I n c . 606 Petersen Way Kenai, AK 99611 Office: (907) 283-1919 Fax: (907) 283-0450 klauder@alaska.net CLIENT: PROJECT: D C B CONFORMED DRAWING SET P:\E13\E13-2002 Homer Harbor Masters Office\050 DWG\E13-2002_HOMER HARBORMASTER_ELECTRICAL.rvt 7/9/2014 9:33:00 AM E13-2002 EDC BLS BLS 7-11-2014 E5.1 HO M E R H A R B O R MA S T E R ' S O F F I C E CI T Y O F H O M E R 49 1 E . P I O N E E R A V E N U E HO M E R , A L A S K A 9 9 6 0 3 ELECTRICAL PANEL SCHEDULES EIC JOB NO:E13 2002 7-11-2014 LOAD CLASSIFICATIONS SCHEDULE NOTES REF NOTE 'KEY' '(x)'DENOTES A GENERAL,NON REFERENCED,NOTE.NUMBERED NOTES ARE REFERENCED FROM THE LOAD CLASSIFICATIONS SCHEDULE. (A) NOT ALL LOAD CLASSIFICATIONS ARE NECESSARILY USED.ONLY CLASSIFICATIONS FROM LOADS THAT ARE CONNECTED TO EACH PANEL ARE SHOWN IN THE SUMMARY SECTION OF THE PANEL SCHEDULES. 1 THE NEC DEMAND PERCENTAGE IS SHOWN AS A WEIGHTED AVERAGE.FOR EXAMPLE 125%OF 100VA PLUS 100%OF 100VA WILL SHOW THE WEIGHTED AVERAGE PERCENTAGE OF 112.5%RESULTING IN 225VA. LOAD CLASSIFICATIONS SCHEDULE CLASS. NEC REFERENCE DESCRIPTION APLNC NEC 2011:220.53 75%OF FOUR OR MORE APPLIANCES CONT NEC 2011:210.20(A) 125%OF THE CONTINUOUS LOAD DRYR NEC 2011:220.54 TABLE 220.54 ELECTRIC CLOTHES DRYERS DWELLING UNIT(S). ETR NEC 2011:220.87 RECORDED DEMAND LOAD *125% GNR NEC 2011:220.12;220.14(J); 200.42 GENERAL LIGHTING LOADS (DWELLING)3VA PER SQ.FT.AND INCLUDES ALL OUTLETS SPECIFIED IN 220.14(J). DEMAND:FIRST 3,000VA OR LESS @ 100%;3,001 120,000VA @ 35%;>120,000VA @ 25%.(SEE NOTE 1) GNRH NEC 2011:220.12;220.14(J); 200.42 GENERAL LIGHTING LOADS (HOTEL/MOTELS &APARTMENT BLDGS W/O TENANT COOKING)2VA PER SQ.FT.AND INCLUDES ALL OUTLETS SPECIFIED IN 220.14(J).DEMAND:FIRST 20,000VA OR LESS @ 50%;20,001 100,000VA @ 40%;>100,000VA @ 30%.(SEE NOTE 1) KTCH NEC 2011:220.56 TABLE 220.56 DEMAND FACTORS FOR KITCHEN EQUIPMENT. LTG NEC 2011:210.20(A) LIGHTING LOADS CONSIDERED TO BE CONTINUOUS.125%OF THE CONTINOUS LOAD. MCA (SEE MTR)THE LOAD IS BASED ON THE GIVEN MCA (MINIMUM CIRCUIT AMPACITY)WHICH INCLUDES 125%OF THE LARGEST MOTOR OF THE UNIT.100%OF THE MCA LOAD. MTR NEC 2011:430.24 125%OF THE FULL LOAD CURRENT RATING OF THE HIGHTEST RATED MOTOR PLUS THE SUM OF THE FULL LOAD CURRENT RATINGS OF ALL OTHER MOTORS.(SEE NOTE 1) NCDN NEC 2011:220.60 NONCOINCIDENT LOADS:WHERE IT IS UNLIKELY THAT TWO OR MORE NONCOINCIDENT LOADS WILL BE IN USE SIMULTANEOUSLY,THE LARGEST LOAD WILL BE USED.LOADS CLASSIFIED AS NCDN WILL HAVE ZERO LOAD. NCNT NEC 2011:210.20(A) 100%OF THE NON CONTINUOUS LOAD REC NEC 2011:220.44 NON DWELLING RECEPTACLE LOADS =FIRST 10KVA OR LESS AT 100%PLUS REMAINDER OVER 10KVA AT 50%.(SEE NOTE 1) RNGE1 NEC 2011:220.55 TABLE 220.55 COLUMN A:LESS THAN 3.5KW RATING RNGE2 NEC 2011:220.55 TABLE 220.55 COLUMN B:3.5KW 8.75KW RATING RNGE3 NEC 2011:220.55 TABLE 220.55 COLUMN C:NOT OVER 12KW RATING NOTES: NEC DEMAND AMPS:239 A NCNT 20.800 kVA 100.00% 20.800 kVA CONNECTED AMPS:230 A CONT 8.000 kVA 125.00% 10.000 kVA NEC DEMAND KVA:86.234 kVA LTG 8.811 kVA 125.00% 11.014 kVA CONNECTED KVA:83.031 kVA REC 18.540 kVA 76.97% 14.270 kVA MTR 26.880 kVA 112.17% 30.150 kVA LOAD CLASSIFICATION CONNECTED NEC DEMAND TOTAL NEC PANEL TOTALS SUMMARY BY LOAD TYPE TOTAL AMPS/PHASE:239.8 219.9 236.8 TOTAL KVA/PHASE:28.5 26.4 28.1 41 - SPACE --- --0.00 0.00 -- -- - SPACE -42 39 - SPACE --- --0.00 0.00 -- -- - SPACE -40 37 - SPACE --- -- 0.00 0.00 -- -- - SPACE -38 35 - SPACE --- --0.00 0.00 -- -- - SPACE -36 33 - SPACE --- --0.00 0.00 -- -- - SPACE -34 31 - SPACE --- -- 0.00 0.00 -- -- - SPACE -32 29 - SPACE --- --0.00 0.00 -- -- - SPACE -30 27 - SPACE --- --0.00 0.00 -- -- - SPACE -28 25 - SPACE --- -- 0.00 0.00 -- -- - SPACE -26 23 - SPACE --- --0.00 0.00 -- -- --24 21 - SPACE --- --0.00 0.00 -- -- --22 19 - SPACE --- -- 0.00 0.00 3 100 - SPACE -20 17 ---- --4.36 0.00 -- -- --18 15 ---- --4.36 0.00 -- -- --16 13 MTR RTU-1 45 3 4.36 0.00 3 100 -SPACE-14 11 ---- --12.94 0.00 -- -- --12 9 ---- --12.19 0.00 -- -- --10 7 PANEL 'B'150 3 12.27 0.00 3 100 -SPACE-8 5 ---- --10.84 0.00 -- -- --6 3 ---- --9.83 0.00 -- -- --4 1 PANEL 'A'150 3 11.88 0.00 3 100 -SPACE-2 CKT LOAD DESCRIPTION AMP P A B C P AMP LOAD DESCRIPTION CKT MAIN: MLO MOUNTING: SURFACE BUS: 400 A / OPD: 400 A ENCLOSURE: NEMA 1 VOLTAGE: 208Y/120V, 3PH, 4W LOCATION: ELECTRICAL/IT ROOM 109 PANEL "MDP"SCHEDULE 1. CONTROL VIA LIGHTING CONTACTOR 'LC-1'. 2. PROVIDE HANDLE LOCK-ON DEVICE. NOTES: NEC DEMAND AMPS:100 A NCNT 8.600 kVA 100.00% 8.600 kVA CONNECTED AMPS:90 A CONT 5.000 kVA 125.00% 6.250 kVA NEC DEMAND KVA:35.944 kVA LTG 6.251 kVA 125.00% 7.814 kVA CONNECTED KVA:32.547 kVA REC 10.080 kVA 99.60% 10.040 kVA MTR 2.616 kVA 123.85% 3.240 kVA LOAD CLASSIFICATION CONNECTED NEC DEMAND TOTAL NEC PANEL TOTALS SUMMARY BY LOAD TYPE TOTAL AMPS/PHASE:100.3 81.9 91.6 TOTAL KVA/PHASE:11.9 9.8 10.8 41 NCNT HC DOOR OPERATOR 101, 102 20 1 1.00 1.25 -- -- --42 39 REC IT ROOM 109 20 1 0.36 1.25 2 30 CONT TELECOM RACK 109 40 37 REC TTB 109 20 1 0.36 1.25 -- -- --38 35 REC EXTERIOR 20 1 0.18 1.25 2 30 CONT TELECOM RACK 109 36 33 REC EXTERIOR 20 1 0.36 1.25 -- -- --34 31 NCNT COPIER 113 20 1 1.50 1.25 2 15 MTR CU-1 32 29 REC ADMIN OPEN OFFICE 112 20 1 1.86 0.00 1 20 SPARE 30 27 REC ADMIN OPEN OFFICE 112 20 1 0.72 0.00 1 20 SPARE 28 25 REC ADMIN OPEN OFFICE 112 20 1 0.54 1.00 1 20 NCNT FIRE ALARM PANEL 109 [NOTE 2] 26 23 REC ADMIN OPEN OFFICE 112 20 1 0.72 1.00 1 20 NCNT INTRUSION PANEL 109 [NOTE 2] 24 21 REC ADMIN OPEN OFFICE 112 20 1 0.36 1.20 1 20 LTG FUTURE SITE SIGN [NOTE 1] 22 19 REC ADMIN OPEN OFFICE 112 20 1 0.72 0.11 1 20 LTG EXTERIOR [NOTE 1]20 17 REC ARCTIC ENTRY 101, MTR CUH-1 20 1 0.30 0.08 1 20 LTG EXTERIOR [NOTE 1] 18 15 REC ROOM 102, 104 20 1 0.72 0.58 1 20 LTG & REC MEN'S R.R. 106 16 13 REC ROOM 103, 112 20 1 0.54 0.77 1 20 LTG & REC WOMEN'S R.R. 105 14 11 REC ADMIN STRG/SAFE ROOM 111 20 1 0.72 0.66 1 20 LTG ROOM 101, 102, 104 12 9 REC HARBOR MASTER OFFICE 110 20 1 1.26 0.82 1 20 LTG ADMIN OPEN OFFICE 112 10 7 NCNT U/C REFRIGERATOR 108 20 1 0.60 1.26 1 20 LTG ROOM 112, 104 8 5 NCNT COFFEE MAKER 108 20 1 1.50 0.32 1 20 LTG ROOM 103, 107 6 3 REC CONFERENCE ROOM 108 20 1 0.36 0.59 1 20 LTG ROOM 110, 109, 111 4 1 REC CONFERENCE ROOM 108 20 1 1.08 0.90 1 20 LTG ROOM 108 2 CKT LOAD DESCRIPTION AMP P A B C P AMP LOAD DESCRIPTION CKT MAIN: MLO MOUNTING: SURFACE BUS: 225 A / OPD: 150 A ENCLOSURE: NEMA 1 VOLTAGE: 208Y/120V, 3PH, 4W LOCATION: ELECTRICAL/IT ROOM 109 PANEL "A"SCHEDULE NO. DATE CITY OF HOMER PUBLIC WORKS DEPT APPROVED FOR CONSTRUCTION NOTES: NEC DEMAND AMPS:110 A NCNT 12.200 kVA 100.00% 12.200 kVA CONNECTED AMPS:104 A CONT 3.000 kVA 125.00% 3.750 kVA NEC DEMAND KVA:39.678 kVA LTG 2.560 kVA 125.00% 3.200 kVA CONNECTED KVA:37.404 kVA REC 8.460 kVA 100.00% 8.460 kVA MTR 11.184 kVA 107.90% 12.068 kVA LOAD CLASSIFICATION CONNECTED NEC DEMAND TOTAL NEC PANEL TOTALS SUMMARY BY LOAD TYPE TOTAL AMPS/PHASE:102.3 101.6 107.9 TOTAL KVA/PHASE:12.3 12.2 12.9 41 SPARE 20 1 0.00 1.77 -- -- --42 39 REC ROOF 20 1 0.36 1.77 2 30 MTR AC-1 40 37 REC EXTERIOR 20 1 0.36 2.50 -- -- --38 35 REC SHOP/GARAGE 123, MTR UH-2 20 1 0.91 2.50 2 30 NCNT DRYER 122 36 33 CONT HEADBOLT HEATER 20 1 1.50 1.50 1 20 NCNT WASHER 122 34 31 REC SHOP/GARAGE 123 20 1 0.54 1.26 -- -- --32 29 REC LOCKER ROOM 121 20 1 0.54 1.26 -- -- --30 27 MTR DISPOSAL 116 20 1 0.86 1.26 3 20 MTR CP-1, CP-2, CP-4 28 25 NCNT MICROWAVE 116 20 1 1.50 0.00 1 20 SPARE 26 23 NCNT MICROWAVE 116 20 1 1.50 0.00 1 20 SPARE 24 21 REC BREAK ROOM 116 20 1 0.36 0.00 1 20 SPARE 22 19 NCNT COFFEE MAKER 116 20 1 1.50 0.00 1 20 SPARE 20 17 NCNT REFRIGERATOR 116 20 1 1.20 0.00 1 20 SPARE 18 15 REC OPERATIONS 114 20 1 0.54 0.72 1 20 MTR CP-3,CP-5 16 13 REC OPERATIONS 114 20 1 0.54 1.50 1 20 MTR B-1 14 11 REC OPERATIONS 114 20 1 0.72 0.72 1 20 REC MECH RM 120, MTR GMT-1 12 9 CONT 20 1 1.50 0.80 1 20 LTG MECH RM 120, MTR UH-2, EF-1 10 7 REC ROOM 116, 118, 114 20 1 0.54 0.68 1 20 LTG Room 121, 123 8 5 REC MEETING ROOM 119 20 1 0.72 1.10 1 20 LTG Room 118, 114, 116 6 3 REC STORAGE 117 20 1 0.54 0.48 1 20 LTG Room 119, 117, 115 4 1 REC DEPUTY OFFICE 115 20 1 1.08 0.27 1 20 LTG & REC UNISEX RESTROOM 122 2 CKT LOAD DESCRIPTION AMP P A B C P AMP LOAD DESCRIPTION CKT MAIN: MLO MOUNTING: SURFACE BUS: 225 A / OPD: 150 A ENCLOSURE: NEMA 1 VOLTAGE: 208Y/120V, 3PH, 4W LOCATION: ELECTRICAL/IT ROOM 109 PANEL "B"SCHEDULE RADIO EQUIPMENT HEADBOLT HEATER COFFEE MAKER 108 113 WOMEN'S R.R. 105 1 Record Drawings 11-2016 1 240320 PACAB Work Session Laydown-Uplands