Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
02042025 Planning & Zoning Packet
Planning & Zoning Commission Meeting Packet Regular Meeting Tuesday, February 4, 2025 Council Chambers, City Hall 7: 00 p.m. 1963 1965 2005 kintual All-Amenca City 1 I I.. The City of Seward, Alaska PLANNING & ZONING COMMISSION MEETING AGENDA City Council Chambers, 410 Adams Street Please silence all cell phones and devices during the meeting Chair Carol Griswold Vice Chair Brenan Hornseth Commissioner Nathaniel Charbonneau Commissioner Vanessa Verhey Commissioner Sean Ulman Commissioner Rhonda Hubbard Commissioner Clare Sullivan Community Development Director Daniel Meuninck City Planner Courtney Bringhurst Executive Assistant Clara Brown City Clerk Kris Peck February 4, 2025 at 7:00 p.m. 1. CALL TO ORDER 2. PLEDGE OF ALLEGIANCE 3. ROLL CALL 4. CITIZEN COMMENTS ON ANY SUBJECT EXCEPT THOSE ITEMS SCHEDULED FOR PUBLIC HEARING (Those who have signed in will be given the first opportunity to speak. Time is limited to 3 minutes per speaker and 36 minutes total time for this agenda item.) 5. APPROVAL OF AGENDA AND CONSENT AGENDA (Approval of Consent Agenda passes all routine items listed under Item 7. Consent Agenda items are not considered separately unless a commissioner requests. In the event of such a request, the item is returned to the Regular Agenda. Marked with *.) 6. CONSENT AGENDA A. Minutes of Preceding Meeting 1)* Approve January 7, 2025 Planning & Zoning Commission Meeting Minutes 5 7. SPECIAL ORDERS, PRESENTATIONS, AND REPORTS A. Proclamations and Awards - None B. City Administration Report C. Other Reports and Announcements - None D. Presentations (Presentations are limited to ten minutes each, excluding Q&A, and are limited to two per meeting unless increased by the commission.) - None 8. PUBLIC HEARINGS (Public hearing comments are limited to five (5) minutes per person. After all speakers have spoken, a person may speak for a second time for no more than one (1) minute.) A. Resolutions Requiring Public Hearing Planning & Zoning Commission Meeting Agenda February 4, 2025 2 1) Resolution 2025-004 of the Planning and Zoning Commission of the City of Seward, Alaska, Granting a Variance from Seward City Code 15.10.220 Development Requirements to OBI Seafoods to install a condenser unit above their building, reaching a height no taller than 39'; Located at 601 Port Avenue; Marina Subdivision, Block 2 Replat, Lot 2A, Block 2; Within the Harbor Commercial (HC) Zoning District 11 2) Resolution 2025-005, of the Planning and Zoning Commission of the City of Seward, Alaska, Granting a Conditional Use Permit to Chugachmiut to construct and operate a pharmacy drive-thru window at the new Chugachmiut Regional Health Center on Fort Raymond Subdivision Replat No 1, 2022 Addition, Lot 7A-2; Located at 704 Aspen Lane; Within an Auto Commercial (AC) Zoning District ..32 3) Resolution 2025-006, of the Planning and Zoning Commission of the City of Seward, Alaska, Granting a Conditional Use Permit to The Tufted Puffin LLC to operate a drive-thru window to sell retail cannabis products and non -cannabis food and beverage items on Lot 1, Block 2, North Harbor Subdivision; Located at 408 Port Avenue; Within an Auto Commercial (AC) Zoning District .50 9. UNFINISHED BUSINESS A. Resolutions - None 10. NEW BUSINESS A. Resolutions 1) Resolution 2025-007, of the Planning and Zoning Commission of the City of Seward, Alaska, Recommending City Council Approval of the Planning and Zoning Commission Priorities for January 2025 to January 2026 ..76 B. Other New Business 1) Discuss the work session topics for Tuesday, February 18, 20 11. INFORMATIONAL ITEMS AND REPORTS (No action required.) A. Reminder of Meetings 1) Work session on Tuesday, February 18th, 2025 at 5:30 pm in City Hall. 2) Special meeting on Tuesday, February 18t1', 2025 at 7:00 pm City Hall. 3) Regular meeting on Tuesday, March 4th, 2025, at 7:00 pm in City Hall. B. Other Items 12. CITIZEN COMMENTS (There is no sign in for this comment period. Time is limited to five (5) minutes per speaker.) Planning & Zoning Commission Meeting Agenda February 4, 2025 25. Council Chambers at in Council Chambers at Council Chambers at 3 13. COMMISSION AND ADMINISTRATION COMMENTS AND RESPONSES TO CITIZEN COMMENTS 14. ADJOURNMENT Planning & Zoning Commission Meeting Agenda February 4, 2025 4 City of Seward, Alaska Planning & Zoning Commission Meeting Minutes January 7, 2025 Volume 8, Page CALL TO ORDER The January 7, 2025, regular meeting of the Planning & Zoning Commission was called to order at 7:00 p.m. by Chair Carol Griswold. OPENING CEREMONY Commissioner Nathaniel Charbonneau led the Pledge of Allegiance to the flag. ROLL CALL There were present: Carol Griswold, presiding, and Brenan Hornseth Nathaniel Charbonneau Vanessa Verhey Sean Ulman Rhonda Hubbard Clare Sullivan comprising a quorum of the Commission; and Daniel Meuninck, Community Development Director Courtney Bringhurst, City Planner Clara Brown, Executive Assistant Kris Peck, City Clerk Jodi Kurtz, Deputy City Clerk Excused — Verhey Absent — None Vacant — None CITIZEN COMMENTS ON ANY SUBJECT - None APPROVAL OF AGENDA AND CONSENT AGENDA Motion (Sullivan/Charbonneau) Approval of Agenda and Consent Agenda Motion Passed Unanimous The clerk read the following approved consent agenda items: Approve December 3, 2024, Planning & Zoning Commission Meeting Minutes 5 City of Seward, Alaska Planning & Zoning Commission Meeting Minutes January 7, 2025 Volume 8, Page SPECIAL ORDERS, PRESENTATION, AND REPORTS City Administration Report Community Development Director Daniel Meuninck encouraged the public to fill out the Comprehensive Plan surveys. He reminded everyone that business licenses are due for annual renewal for 2025. Meuninck said P&Z would have three commissioner seats expiring at the end of February. Lastly, he announced the upcoming Joint Work Session with the City Council on Monday, January 27, at 5:30 p.m. PUBLIC HEARINGS Resolutions Requiring Public Hearing Resolution 2025-001, Recommending Seward City Council and Kenai Peninsula Borough Approval of the Preliminary Plat of Fourth of July Creek Subdivision, Seward Marine Industrial Center (SMIC), That Point of Block 10, Excluding Lots 1 & 2; Located at 3207 Sorrel Road; Creating Tract A & B, Block 10, Fourth of July Creek Subdivision, SMIC, Spring Creek Replat Motion (Charbonneau/Sullivan) Approval of Resolution 2025-001 City Planner Courtney Bringhurst stated that the commission revisited late 2023 discussions on the Municipal Lands Inventory Management Plan and the replating of a large parcel in the SMIC area. She explained how this replat would divide the land into two parcels. She also commented on a 50-foot easement in the campground area that was reviewed with the Public Works Director. The recommendation was to vacate the public access easement and collaborate with Parks and Recreation for better access options as development continues. Bringhurst noted that the public did not require a designated public access easement to access the property once it was rezoned as a park. She spoke of the primary purpose of the current 50-foot public access easement was to ensure public access to the beach. She also spoke of the support of the recommendation to vacate the easement for flexibility for future development or access planning. [Stacy Wessel, AK Land Surveyor, was on the phone if the commission had any questions.] Notice of the public hearing being posted and published as required by law was noted and the public hearing was opened. No one appeared and the public hearing was closed. The commission discussed public access and land management near Spring Creek, emphasizing the public's right to beach access under the Alaska State Constitution, which included private property within beach grass or tideland areas. The commission highlighted challenges with unclear boundaries, survey costs, and easement agreements for formal access points. Proposals included rezoning areas like Spring Creek Campground as parkland to secure recreational use. Concerns about boundaries, private land access, and physical barriers like the creek were raised. Further research and negotiation were deemed necessary to establish practical and legal access routes while protecting public rights. 6 City of Seward, Alaska Planning & Zoning Commission Meeting Minutes January 7, 2025 Volume 8, Page Further discussion included adjusting the 50-foot utility easement for a sewer line near Spring Creek to accommodate a separate 10-foot pedestrian easement. Overlapping easements were considered, but concerns arose about maintaining unencumbered access for utility repairs. Public Works suggested relabeling the utility easement as a "50-foot sewer easement" to prevent additional uses. A separate pedestrian easement parallel to Spring Creek was proposed as a compromise to balance utility access and public needs. The commission was open to this approach to address both priorities. Resolution 2025-001 was amended to change the name to Seward Marine Industrial Center (SMIC), Spring Creek Park Replat. Resolution 2025-001 was amended to add Section 2. 10'-20' public easement to plat for pedestrian public access easement. Main Motion as Amended Passed Unanimous Resolution 2025-002, Recommending Seward City Council and Kenai Peninsula Borough Approval of the Preliminary Plat of Tract B, Block 10, Fourth of July Creek Subdivision, SMIC, Spring Creek Replat; Lot 3, Block 8, Fourth of July Creek Subdivision, SMIC Seward Ship's Drydock Replat; and Lot 4A-4, Block 7, Fourth of July Creek Subdivision, SMIC, JAG Replat; Located at 3207, 3311, & 3314 Sorrel Road; Creating Tracts B-1 & B-2, Block 10 and Lots 4A-5 & 4A-6, Block 7, Fourth of July Creek Subdivision, SMIC, Park Replat Motion (Charbonneau/Sullivan) Approval of Resolution 2025-002 Bringhurst noted a corrected application was included for proper documentation. The proposed plat involved parking and trail access for Fourth of July Beach and the intention was to rezone as park. She also addressed a second parcel near Sorrel Road would include beach parking. The 50- foot cul-de-sac at Sorrel Road was confirmed to meet standards which removed the need for further verification. Notice of the public hearing being posted and published as required by law was noted and the public hearing was opened. No one appeared and the public hearing was closed. Resolution 2025-002 was amended to strike Section 1. The Commission hereby recommends that a full cul Resolution 2025-002 was amended to update the replat with the name Fourth of July Creek Subdivision, Seward Marine Industrial Center (SMIC), Fourth of July Beach Park Replat. Main Motion as Amended Passed NEW BUSINESS Resolutions Unanimous City of Seward, Alaska Planning & Zoning Commission Meeting Minutes January 7, 2025 Volume 8, Page Resolution 2025-003, Recommending Seward City Council and Kenai Peninsula Borough Approval of the Preliminary Plat of Lots 1, 2, & 3, Block 10, Original Townsite of Seward; Located at 237 & 235 Fourth Ave; Creating Lot 1A, Block 10, Seward Original Townsite, Kawabe Park Replat Motion (Sullivan/Charbonneau) Approval of Resolution 2025-003 Bringhurst clarified that the replat of Kawabe Park was a straightforward process that did not require a public hearing. This replat involved vacating the interior lot lines from the historic Seward Townsite Plat. The park zoning, use, and boundaries would remain unchanged. The replat would consolidate the area into a single 9,000-square-foot lot, with no alterations to its current designation or purpose. Motion Passed Other New Business Discussion of building height overlay Unanimous The commission considered proposals for building height overlays within the city to present to the City Council. The commission discussed maintaining the current 34-foot height limit across all zoning districts and explored overlay areas where buildings could be up to 38-feet (three stories) and 50-feet (four stories) could be permitted. Commissioners discussed potential areas along Seward Highway, SMIC, and specific sections of downtown for taller buildings. They considered factors like impacts, viewshed, zoning compatibility, and public safety. Their concerns included effects on the city's small-town atmosphere, infrastructure demands, and public feedback. Commissioners emphasized the need for a public work session before finalizing any recommendations. The goal was to approach the upcoming Joint Work Session with general proposals and rationale while leaving detailed decisions for subsequent discussions. Discuss work session topic for Tuesday, January 21, 2025 The commission set their work session topic for Tuesday, January 21, 2025 to include: Municipal Lands Inventory and Management Plan Provide recommendations for city -owned land that could be used for housing P&Z Priorities The commission also wanted to review documents in preparation for the upcoming Joint Work Session with City Council, which included building height, accessory dwelling units (ADUs), and marijuana establishments. INFORMATIONAL ITEMS AND REPORTS Reminder of Meetings Work session on Tuesday, January 21, 2025, at 6:00 p.m. 8 City of Seward, Alaska Planning & Zoning Commission Meeting Minutes January 7, 2025 Volume 8, Page Joint work session with City Council on Monday, January 27, 2025, at 5:30 p.m. Regular meeting on Tuesday, February 4, 2025, at 7:00 p.m. CITIZEN COMMENTS - None BOARD AND ADMINISTRATION COMMENTS & RESPONSE TO CITIZEN COMMENTS Sullivan thanked everyone for sharing their comments and thoughts. She valued differing opinions and viewpoints so the commission could effectively represent the community. Sullivan also thanked city administration and the clerk's office. Charbonneau thanked city administration for all their hard work. Hornseth thanked city administration and the surveyor Stacy Wessel for their expertise. Hubbard appreciated all the diverse ideas and she appreciated staff for helping make the community a better place. She wished everyone a Happy New Year! Chair Griswold asked Community Development staff about the final standings of the racquet ball tournament. Meuninck responded that the city staff had swept the podium at the racquetball tournament. Courtney Bringhurst had taken the gold, Meuninck got the silver, and Russ White took home the bronze. in the racquet ball tournament. He thanked the Commission for their hard work. He shared his remembrance of the time he started as Community Development Director and several P&Z meetings were cancelled due to lack of quorum. Now everyone was catching up with priorities and tackling some harder issues. Clara Brown wished everyone a Happy New Year and announced that she had now been working in the Community Development office for a full year. and mentioned that she handed out promo items at Safeway to encourage people to take the Comprehensive Plan surveys. Hubbard encouraged city staff to get information out to public on Facebook in hopes of more public engagement. She lamented the loss of the local newspaper. Griswold was pleased to see the commission accomplishing many important things and it was a good feeling. She thanked city administration and the clerk's office. ADJOURNMENT The meeting was adjourned at 8:43 p.m. 9 City of Seward, Alaska Planning & Zoning Commission Meeting Minutes January 7, 2025 Volume 8, Page Jodi Kurtz Deputy City Clerk Carol Griswold Chair 10 Planning and Zoning Agenda Statement Meeting Date: February 4, 2025 To: Planning and Zoning Commission Through: Daniel Meuninck, Community Development Director From: Applicant Subject: Resolution 2025-004 of the Planning and Zoning Commission of the City of Seward, Alaska, Granting a Variance from Seward City Code 15.10.220 Development Requirements to OBI Seafoods to install a condenser unit above their building, reaching a height no taller than 39'; Located at 601 Port Avenue; Marina Subdivision, Block 2 Replat, Lot 2A, Block 2; Within the Harbor Commercial (HC) Zoning District Background and justification: Ocean Beauty Icicle (OBI) Seafoods has submitted a variance application to the Planning and Zoning Commission requesting a relaxation of the 34' building height requirement to install a condenser unit above the existing building located at 601 Port Avenue (Kenai Peninsula Borough parcel ID number 14524015). The top of the condenser would reach a height of 39'9", which is five feet and nine inches above the height allowed by Seward City Code. OBI has been working with the Building Department and Community Development for many months to find a suitable location to install a replacement condenser unit to improve the refrigeration system for the seafood processing plant and reduce electric and water use. However, due to the location of the building on the property, all other preferred locations for the condenser are within easements or encroaching into a right-of-way. The condenser also cannot be placed on the south side of the building as it would be more susceptible to saltwater corrosion. The location of the condenser is also limited as it must be placed near the compressor room, which is located on the northeast side of the building. The weight of the condenser makes it impractical and unsafe to place it on top of the building directly adjacent to or above the compressor room. An engineered stand is required to adequately support the weight of the condenser. The placement of the condenser above the building is also important for its operation, as the ammonia that is condensed within the unit depends on gravity to drain to the compressor room within the building. So, regardless of where the condenser is placed on the property, it would need to be placed at a sufficient height to adequately drain to the compressor room. Due to the limitations stated above, the applicant is proposing to place the condenser on a stand installed in one of the building's loading dock spaces in a corner on the north side of the building. The stand would be restricted to approximately 8' in width to occupy only one loading dock space. The condenser unit, however, is 9' 10" wide, which is an additional reason for placing it 11 above the building to not conflict with the other adjacent loading dock spaces. If the condenser were placed just above the building height (19' 9"), the top of it would still reach 35'. However, the applicant would like a minimum of four feet between the top of the building and the bottom of the platform that the condenser sits on to provide space for snow buildup. The applicant is willing to discuss potentially lowering the platform a couple of feet if the Commission would be more favorable to a lower maximum height. Staff recommended that the applicant apply for a variance to receive additional input from the Commission to evaluate this situation as the condenser unit is technically not a building or structure, it is a mechanical piece of equipment. The stand on which it will be placed is a structure, 24'9" high, which is compliant with the building height. It is the placement of the mechanical piece of equipment, the condenser, which is 15' tall, on top of the stand, for a total height of 39' 9" that puts the top of the condenser above the allowed 34' building height. Building Code does not count "towers, spires, steeples and other `rooftop structures' in the building height. A rooftop structure is defined as "a structure erected on top of the roof deck or on top of any part of a building enclosing a stairway, tank, elevator machinery or ventilating apparatus, or such part of the shaft as extends above the roof." This definition does not specifically mention mechanical equipment; however, there is a definition in the building code for a mechanical equipment screen, which is defined as, "a rooftop structure, not covered by a roof, used to aesthetically conceal plumbing or mechanical equipment from view." This definition implies that mechanical equipment can be placed above the allowed building height since a structure used to conceal such equipment is considered a rooftop structure and also allowed to be constructed above the allowed building height. Seward City Code § 15.10.325 allows an individual to apply for a variance or a relaxation of the development requirements when the literal enforcement of regulations within Title 15 would deprive the property owner of the reasonable use of their property. The Commission determines whether the variance should be allowed or denied based on the findings they establish for the following review criteria: 1. The proposed action must be consistent with all of the general conditions required for a conditional use permit; a. The use is consistent with the purpose of this chapter (the Seward Zoning Code) and the purposes of the zoning district. b. The value of adjoining property will not be significantly impaired. c. The proposed use is in harmony with the Seward Comprehensive Plan. d. Public services and facilities are adequate to serve the proposed use. e. The proposed use will not be harmful to the public safety, health or welfare. 2. Special conditions and circumstances exist which are peculiar to the land or structures involved and which are not applicable to other lands and structures in the same district; 3. The special conditions and circumstances have not been caused by actions of the applicant; 4. Financial hardship or inconvenience shall not be a reason for granting a variance; 12 5. Other nonconforming land use or structures within the district shall not be considered grounds for granting a variance; 6. A variance shall be the minimum variance necessary to permit the reasonable use of the land or structure; and 7. A variance shall not be granted which will permit a land use in a district in which that use is otherwise prohibited Surrounding Land Use and Zoning: Development Requirements: In the Harbor Commercial zoning district, the maximum building height is 34'. The setbacks are: front yard — none, side yard — 5', side yard adjacent to street — none, rear yard — 10'*. The accessory building height is 20'. *Table 15.10.222 NOTE 5. In the HC District, parcels abutting mean high tide —No rear yard setback; parcels abutting the waterfront boardwalk —Five feet; and parcels not abutting the waterfront boardwalk or mean high water mark —Ten feet. Surrounding Land Use: The properties to the north are zoned Industrial and used for warehousing and employee housing. The properties to the east and west are zoned Harbor Commercial and are used for parking, storage, or dock access. To the south of the property is the Seward Boat Harbor. Floodplain Status: The property is not located within a FEMA mapped flood zone. Utilities: The property is connected to city water, sewer, and electricity. Parking: There are no parking requirements for the installation of a condenser unit. There are also no requirements to have a certain number of loading dock spaces. Eliminating a loading dock space to use for the condenser unit will not put OBI Seafoods out of compliance. Comprehensive and Strategic Plan Consistency Information This legislation is consistent with (citation listed): Comprehensive Plan: Vol 1, Chapter 3.1.1.4 — "Support private sector business, employment, and programs." • Support and encourage the growth of business. Strategic Plan: Other: N/A Staff Comments Department Comments No Comment N/A Building Department X Fire Department X 13 Public Works Department X Harbor Department X Police Department X Electric Department X Parks and Recreation X Telecommunications X Property owners within three hundred (300) feet of the proposed Variance were notified of this public hearing. Public notice signs were posted on the property and all other public hearing requirements of Seward City Code § 15.01.040 were complied with. At the time of this publication, the Community Development Department has not received public inquiries. If any correspondence is received after publication of this agenda statement, it will be submitted to the Commissioners for their review. Recommendation Seward City Code 15.10.325 allows the Planning and Zoning Commission to grant variances "when the literal enforcement of this chapter (Title 15) would deprive a property owner of the reasonable use of his/her property." The variance request has met the application requirements, and the Commission has the authority to grant this variance if sufficient findings support the conditions listed in the review criteria (SCC 15.10.325(D)). 14 Sponsored by: Applicant Public Hearing: February 4, 2025 CITY OF SEWARD, ALASKA PLANNING AND ZONING COMMISSION RESOLUTION 2025-004 A RESOLUTION OF THE PLANNING AND ZONING COMMISSION OF THE CITY OF SEWARD, ALASKA, GRANTING A VARIANCE FROM SEWARD CITY CODE 15.10.220 DEVELOPMENT REQUIREMENTS TO OBI SEAFOODS TO INSTALL A CONDENSER UNIT ABOVE THEIR BUILDING, REACHING A HEIGHT NO TALLER THAN 39'; LOCATED AT 601 PORT AVENUE; MARINA SUBDIVISION, BLOCK 2 REPLAT, LOT 2A, BLOCK 2; WITHIN THE HARBOR COMMERCIAL (HC) ZONING DISTRICT WHEREAS, Ocean Beauty Icicle (OBI) Seafoods has submitted a variance application to the Planning and Zoning Commission requesting a relaxation of the 34' building height requirement so that they can install a condenser unit above the existing building located at 601 Port Avenue; and WHEREAS, the Kenai Peninsula Borough parcel ID number for this property is 14524015; and WHEREAS, the maximum height the condenser would reach would be 39'9"; and WHEREAS, the property is located in a Harbor Commercial (HC) zoning district; and WHEREAS, the building height limit in the HC zoning district is 34'; and WHEREAS, the property owner has spent various months working with the Building Department and Community Development to find a suitable location to install this condenser; and WHEREAS, due to the location of the building on the property, all other desirable locations for the condenser were encroaching into the property easements or adjacent right-of- ways; and WHEREAS, the condenser cannot be placed on the south side of the building as it would be more susceptible to saltwater corrosion; and WHEREAS, the condenser needs to placed in proximity to the compressor room, which is located in the northeast portion of the building; and WHEREAS, ammonia from the condenser relies on gravity to drain to the compressor room, requiring the condenser to be placed at a height above the compressor room; and WHEREAS, the weight of the condenser makes it impractical and unsafe to place it on top of the building directly adjacent to or above the compressor room; and 15 PLANNING AND ZONING COMMISSION RESOLUTION 2025-004 Page 2 of 4 WHEREAS, the applicant is proposing to place the condenser on a stand that will be constructed in one of the building's loading dock spaces adjacent to the north side of the building; and WHEREAS, the stand would be restricted to approximately 8' in width to occupy only one loading dock space; and WHEREAS, the width of the condenser unit is 9' 10", requiring it to be placed above the roofline of the building to not conflict with the other adjacent loading dock spaces; and WHEREAS, the applicant would like a minimum of four feet between the bottom of the platform on which the condenser will be placed and the top of the building to accommodate for snow buildup; and and and WHEREAS, the condenser unit is 15' tall and the stand on which it will be placed is 24'9"; WHEREAS, the applicant has stated that there is potential to lower the stand height; WHEREAS, the condenser unit is not a building or part of the building, but rather a piece of mechanical equipment; and WHEREAS, the stand on which the condenser unit will be placed is a structure and is within the allowed building height; and WHEREAS, Building Code does not count "towers, spires, steeples and other `rooftop structures' towards the building height; and WHEREAS, A rooftop structure is defined as "a structure erected on top of the roof deck or on top of any part of a building enclosing a stairway, tank, elevator machinery or ventilating apparatus, or such part of the shaft as extends above the roof."; and WHEREAS, the definition of rooftop structure does not specifically address mechanical equipment; and WHEREAS, the definition of a mechanical equipment screen is "a rooftop structure, not covered by a roof, used to aesthetically conceal plumbing or mechanical equipment from view"; and WHEREAS, from these two definitions it can be implied that mechanical equipment are commonly placed above buildings and excluded from the total building height; and 16 PLANNING AND ZONING COMMISSION RESOLUTION 2025-004 Page 3 of 4 WHEREAS, code is not specifically clear on this matter, staff recommended that the applicant apply for a variance to receive input from the Commission; and WHEREAS, Seward City Code §15.10.325(A) states that an individual may apply for a variance "when the literal enforcement of this chapter would deprive a property owner of the reasonable use of their property; and WHEREAS, the applicant has complied with all of the public hearing requirements of Seward City Code § 15.01.040. NOW, THEREFORE, BE IT RESOLVED BY THE PLANNING AND ZONING COMMISSION OF THE CITY OF SEWARD, ALASKA, that: Section 1. The Commission finds that the proposed use satisfies the following conditions as specified in SCC 15.10.325.D. 1) The proposed action must be consistent with all the general conditions required for a conditional use permit: A. The use is consistent with the purpose of this chapter (the Seward Zoning Code) and the purposes of the zoning district. B. The value of adjoining property will not be significantly impaired. C. The proposed use is in harmony with the Seward Comprehensive Plan. D. Public services and facilities are adequate to serve the proposed use. E. The proposed use will not be harmful to the public safety, health or welfare. 2) Special conditions and circumstances exist which are peculiar to the land or structures involved and which are not applicable to other lands and structures in the same district. 3) The special conditions and circumstances have not been caused by actions of the applicant. 4) Financial hardship or inconvenience shall not be a reason for granting a variance. 5) Other nonconforming land use or structures within the district shall not be considered grounds for granting a variance. 6) A variance shall be the minimum variance necessary to permit the reasonable use of the land or structure. 7) A variance shall not be granted which will permit a land use in a district in which that use is otherwise prohibited. Section 2. Per Seward City Code §15.10.325(f). an approved variance shall lapse six months from the date of approval if the use for which the permit was issued has not been implemented or a building permit obtained. The Commission may grant a six-month extension 17 PLANNING AND ZONING COMMISSION RESOLUTION 2025-004 Page 4 of 4 upon finding that circumstances have not changed sufficiently since the date of initial permit approval. Section 3. The Planning and Zoning Commission finds that the proposed variance, subject to the findings of the Commission, satisfies the criteria for granting a variance to SCC § 15.10.220 Development Requirements and authorizes administration to issue a variance to OBI Seafoods to install a condenser unit above their building, reaching a height no taller than 39', at 601 Port Avenue; Marina Subdivision, Block 2 Replat, Lot 2A, Block 2. Section 4. This resolution shall take effect 10 days following its adoption. PASSED AND APPROVED by the Planning and Zoning Commission this 4t' day of February, 2025. AYES: NOES: AB SENT: ABSTAIN: VACANT: ATTEST: Kris Peck City Clerk (City Seal) THE CITY OF SEWARD, ALASKA Carol Griswold, Chair 18 Context Map Two-family Residential Auto Commercial Harbor Commercial Industrial Resource Management Park Azoa fee N Variance Application Property Map RES 2025-004 - Granting a variance to exceed the building height by 5' to place a condenser unit on top of the OBI Seafoods building Location: 601 Port Ave Parcel #: 14524015 19 APPLICATION FOR VARIANCE City of Seward Planning and Zoning P.O. Box 167, Seward, Alaska, 99664 907-224-4048 This completed application is to be submitted to the Community Development Department no later than four (4) weeks in advance of the next regularly scheduled Planning & Zoning Commission meeting held the first Tuesday of each month. Property Owner/Agent Owner's Contractor(I£ Any) Name: OBI Seafoods Name: Wyatt Refrigeration LLC City of Seward Business License #: Pending Mailing Address: 601 Port Avenue Seward, AK 99664 Alaska Business License #:1032741 Contractor's License #: CON M21465 Contact Phone: David Ramirez 907.229.2477 Mailing Address: 12432 Highway 99 S. #75 Everett, WA 98204 Contact Phone:425.743.7744 E-mail: david.ramirez@obiseafoods.com E-mail. justin@wyattrefrig.com Property Information Size of Property: 2.6 acres Property Tax #:145.240.15 Street Address: 601 Port Ave Legal Description: Lot (s)41 9-A Block 2- Subdivision hkooriv.. cA. S ocl OR_Parcel/Tract_ Section Township Range_ [Attach additional page if necessary] Zoning: ❑City Limits ❑Rural Residential (RR) ■ Single Family Residential (R1) ) • Two Family Residential (R2)❑Multiple Family Residential (R3)❑Urban Residential (UR) ❑Office Residential (OR) aIarbor Commercial (I -IC) ■Auto Commercial (AC) • Central Business District (CB) ❑Industrial (I) ❑Institutional (INS) Park (P) Resource Management (R) 20 The application must be accompanied by: ►[ 'Fee $3 50.00 ❑As -Built Survey by a surveyor registered in the State of Alaska ((if already developed) or ffScaled site plan of undeveloped land which shows: [Property dimensions ❑ location and dimensions of existing and planned buildings ]parking configuration ❑ driveways/access; ❑ natural features Itvariance requested i1 other pertinent information Applicant seeks a variance from the following general requirement(s): A. Variance Request for Code Section(s)#: Code must be referenced 15.10.220 Development Requirements - Table 15.10.222 B. The existing situation is: The only area on the property that allows for proper setback from road requires the installation of the condenser to be above existing building, putting top of condenser at 39' above grade. C. Granting this variance would permit: Replacement of existing condenser(s) with new, more efficient condenser. D. What structures are located on the property? Various buildings, built at different times, of different sizes. The installation of the new condenser would be on Port Ave. E. What is the existing use of the property? Seafood Production F. What is the proposed use of the property? ea o0Production G. What is your development time schedule? As soon as possible 21 The Planning & Zoning Commission may only grant a variance if the Commission finds all of the following conditions are met. Each condition must have a response in as much detail as it takes to meet the condition. Please use additional paper if there is not enough room here for your response. Failure to document your case reduces the likelihood of your variance being granted. The Applicant hereby alleges that: 1. The proposed action is consistent with all of the general conditions required for a conditional use permit as follows: A. The use is consistent with the purposed of the Zoning Code and the purposes of the zoning: B. The value of the adjoining property will not be significantly impaired: C. The proposed use is in harmony with the Seward Comprehensive Plan: D. Public services and facilities are adequate to serve the proposed use: E. The proposed use WILLNOT beharmful to the public safety, health or welfare: All of these stipulations are correct. 2. Special conditions and circumstances exist which are peculiar to the land or structures involved and which are not applicable to other lands and structures in the same district. These special conditions are: We have considered several different areas for the installation of this condenser, but this is the only location that will allow for the proper setback from the property line. 3. The special conditions and circumstances have not been caused by actions of the applicant in that: The refrigeration system is currently using city water for cooling. The installation of this new, evaporative condenser will greatly lessen the amount of city water used. 4. Financial hardship or inconvenience shall not be a reason for granting a variance in that: The installation of this condenser will allow for use of less city water during processing and will increase the efficiency of the refrigeration system. 22 5. Other non -conforming land use or structures within the district shall not be considered grounds for granting a variance in that: The design of this condenser and stand is based on gravity drainage to pressure vessels in refrigeration system, clearance from existing buildings (height), and setback from property lines. 6. The variance granted is the minimum variance that will make possible a reasonable use of the land, building or structure in that: The existing building dictates the required height of the condenser and stand. 7, Granting the variance will not permit a use that is not otherwise permitted in the district in which the property lies in that: The use of the building, seafood processing remains the same. The goal is greater electrical efficiency and use of less water. I hereby certify that all statements and other information submitted are true and accurate to the best of my knowledge, and that I, as applicant have the following legal interest in the property: ✓[ Owner of record; Lessee; Lej Contract Purchaser; duly authorized to act for a person who has the following legal interest : and that the owner of record is knowledgeable of this application if I am not the owner. I understand that the variance fee is non-refundable to cover the cost associated with processing this application and that it does not assure approval of the variance. Justin Wyatt 12/12/24 Owner or Agent Date PROVISIONS: The applicant is advised that issuance of this permit will not relieve responsibility of the owner or owner's agents to comply with the provisions of all laws and ordinances, including federal, state and local jurisdictions, which regulate construction and performance of construction, or with any private deed restrictions. Office Use Only Below This Line EfFee $350.00 OSite Plan ►[Location Map ❑Fee As -Built Survey INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED 23 OBI SEAFOODS 601 PORT AVENUE SEWARD, AK 99664 NEW EVAPORATIVE CONDENSER REFRIGERATION DRAWINGS AMMONIA REFRIGERATION SYSTEM NOTES: 1. REFRIGERATION SYSTEM SHALL COMPLY WITH IIAR 2 2021 2. THE INSTALLATION SHALL COMPLY WITH 2021 IRC 3. THE INSTALLATION SHALL COMPLY WITH 2021 IFC 4. THE INSTALLATION SHALL COMPLY WITH 2021 IMC 5. THE INSTALLATION SHALL COMPLY WITH 2021 IBC Dept. of Hays. �40~` 10' P.U.E. centered an existing i fire hydrant and rote, line 1� p Put n �G oa���eg Qi)v \na'S! (EI) i 52.42' 1^� S8• 958- r 46.27' (East) (Eoeq 1'4.l Public Access & Uliily Easement l663.808 WORK AREA 35�"to PUE- Lot 2A 2.610 Ac. 328 07' Avetke Porgy Block ♦i t0 T— Dock Street 60-00' VICINITY PLAN NOT TO SCALE N8 NORTH 59'48 W DRAWING SCHEDULE SHEET TITLE RO TITLE PAGE R1 REFRIGERATION LAYOUT R2 CONDENSER PIPING DIAGRAM THIS DRAWING IS THE PROPERTY OF WYATT REFRIGERATION CO. THE INFORMATION CONTAINED HEREIN SHALL NOT BE USED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF WYATT REFRIGERATION CO. WYATT REFRIGERATION 12432 HIGHWAY 99S, UNIT 75 EVERETT, WA 98204 TITLE TITLE PAGE PERMIT SET DRAWN BY AJ R ISSUED 11-DEC-24 SCALE NOT TO SCALE SHEET RO 24 6" HSD 4" CD 3/4" FG 2 1 /2" EQ "Cr:, 1' LL NEW CONDENSER LOCATION COMPRESSOR ROOM REFRIGERATION LAYOUT NOT TO SCALE NORTH ABBREVIATIONS CD CONDENSER DRAIN EQ EQUALIZE FG FOUL GAS HSD HIGH STAGE DISCHARGE NOTES THIS DRAWING IS THE PROPERTY OF WYATT REFRIGERATION CO. THE INFORMATION CONTAINED HEREIN SHALL NOT BE USED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF WYATT REFRIGERATION CO. ktri) WYATT REFRIGERATION 12432 HIGHWAY 99S, UNIT 75 EVERETT, WA 98204 601 PORT AVENUE SEWARD, AK 99664 TITLE REFRIGERATION LAYOUT PERMIT SET DRAWN BY AJ R ISSUED 11-DEC-24 SCALE NOT TO SCALE SHEET R1 25 2022© Baltimore Aircoil Company. All Rights Reserved. Condenser - Front view 2'-6 1 /2" — 4' 9" 2'-6 1/2" (4) 4" REFRIG IN (4) 4" REFRIG OUT "coACCESS DOOR \ 0O SAFETY HANDLE -11 1 i 111 SEE DETAIL A cV � CELL 2 FACE B Notes 1) Drawings are not to scale. 2) Dimensions are in feet and inches. Weights are in pounds and include options and accessories. 3) Unless otherwise indicated, connections 3" and smaller are MPT. 4) Dimensions showing location of coil & basin connections are approximate and should not be used for prefabrication of connecting piping. 5) For weight loadings and support requirements, refer to suggested steel support drawing. 6) Area above the air discharge must be unobstructed. 7) Field piping must not be supported by the unit inlet or outlet connections. 8) M = Motor location, M1 = Large Motor Location, M2 = Small Motor Location. Right & Left Hand Unit CELL 2 FACE B DOOR STEP Model Number Shipping Weight Operating Weight Heaviest Section VRC-0796A-1036N-JA 43490 56410 12790 —8 5/8" —1-8" FACE D FACE C Condenser - Side view 17' 11 3/4" i....r •�Y I\!IIII■'IIII\`n11 ■ \ IIII \z,II.,\! Is 36' 2 1/2" FACE C CELL 1 FACE D 8 5/8"- 1'-8 3/8"- 17' 11 3/4" CELL 2 CELL 1 FACE A SEE DETAIL C DOOR STEP COIL CONNECTION NITROGEN CHARGE ASSEMBLY I---+8" DETAIL C SEE DETAIL A 1 1/2" FPT MAKE—UP 3" MPT OVERFLOW 3" MPT DRAIN 4 1/8" 8 1/2" 8 1/2" DETAIL B CELL 1 FACE A Data Version 1.01 DWG Version 1.02 1 1/2" FPT MAKE—UP 3" MPT OVERFLOW • 3" MPT DRAIN 4 1/8" 8 1/2" 8 1/2* DETAIL A ORDER NO: U221179101 DATE: 4/25/2022 11:58:56 AM ConfigVer=12 BALTIMORE AIRCOIL COMPANY Evaporative Condenser 10x36 Two CeII Unit Print DRAWING NUMBER: UP-U221179101 ( (E) BLDG / / 1 - 0" (VERIFY) _/.\6' 36' - 0" S2'2 6 0" / / 18'-0" 18'-0" / / / T (E) SLAB ON GRADE (E) STEM (E) WALL FTG-, WALL _ (E) BLDG j J (E) WALL OPNG / S2.1 ��,`� y(S' A • S2.1 S2.0 �5°' A 6' A ///// %./ \ (TYP) S2.0 7� 0r (TYP) .0r S2.0 r- ,' �°- )ONC FTG W/#6 AT 9"0CEA WAY (TOP & BOT) (TYP) am °-/-% 1' 3" O O / 1,_ 3"� / 4" DIA STEEL PIPE GALV 3 -3" DIA PIPE ,- POST AT 5'-0" OC S2.1 (TYP) T.O. FTG -2' - 0" / B 3' - 0" (E) FINISHED GRADE S2.0 3' - 0" / / (SLOPED)A / / O FOUNDATION PLAN 1/4" = 1 - 0 STL- GRATING PER PLAN CONDENSOR UNIT (56,410 # MAX) • I.IiIT! Co r- LC) 1 (E) FINISHED-, GRADE (VARIES) 1 W 12X40 CONT OVER COL f 2L4X4X3/8 N _o" STL PLATEFORM LEVEL 24'-91/2" Space for snow buildup (E) BLDG (E) SLAB COL CL (N) PAD PER PLAN-' O ELEVATION 1/4" = 1 - 0 COL CL (E) WALL (E) FTG ±14' - 6" (VERIFY) Top of Building +- 19' 9" GRADE LEVEL 0' - Off! STL GRATING PER PLAN I 0 I 0 1 0 (E) CONC PAVEMENT (FIELD VERIFY) 6' - 0" (VERIFY) 18'-0" 18'-0" cr.) X N 4'-0" \ / / \ W-1 2X19- 2X 19 /\ / MIRIE�1l19N_ __ ,,,• ■■ • ��11��inii I ■11111■ ■■■■.a■■■■■■■■■LL.■n■■■■■■■■■■ (4) EQ SPACING (TYP) W12X19 ' II1 T 1:::•! L W12X26 J OO XU NW O z▪ / %�/ W 12X26 \ L \ W 12X26 \ / / / CONDENSER (56,410# MAX) W12X53 11111111111111111 40 (E) ROOF (VERHANG O CONDENSER PLATFORM FRAMING PLAN 1/4" = 1 0 W12X19 I 0 I CONDENSOR UNIT (56,410 # MAX) I 0 I 1 0 1 W 12X26 -1/2" THK DRAG PL AT WF BM BOT FLANGE W12X19 "-(E) WALL (E) FINISHED GRADE (E) WALL W12X26 2L4X4X3/8 W12X26 W12X26 W12X26 • I ,N 6� (TYP) 2L4X4X3/8 HSS10X10X1/2 (E) SLOPED GRADE N gC W12X19 co r 1— © ELEVATION 1/4" = 1 0 COL CL (N) PAD PER PLAN COL CL COL CL X c® 11 1" BAR GRATING (TYP) S2.0 (4) EQ SPACING m N W12X19 (Q -r- 1-2X53 W12X26 / / J O O ✓ U Xcx N LLJ W12X26 X // W12X19 4'-0" \T >O \ z \ O U 1" DIA HORIZ ROD BRACING (TYP) W/ #3 CLEVIS AND 1" DIA PIN. USE TURNBUCKLE TO DRAW TIGHT W / 1/ / W12X19\ / /7 / \ / / \ I 12X19 \ / \ S2.1 (TYP) O i0 Zh O \j FOUNDATION NOTES 1. COORDINATE DIMENSIONS WITH MECHANICAL PLANS. DIMENSIONS ARE CONTROLLED BY THE MECHANICAL DRAWINGS. ANY DISCREPANCY IN DIMENSION BETWEEN MECHANICAL AND STRUCTURAL DRAWINGS MUST BE BROUGHT TO THE ENGINEER'S ATTENTION. 2. GC TO FIELD VERIFY INFO OF EXISTING FOUNDATION AS SHOWN IN FOUNDATION SECTIONS AND DETAILS AND AS CALLED OUT ON FOUNDATION PLAN. REPORT TO ENGINEER OF RECORD IN CASE ANY DISCREPANCY OR ANY IN CASE OF CONFLICT W/ EXISTING STRUCTURE. 3. DO NOT UNDERMINE BASE OF EXISTING FOOTING AND DO NOT OVER -EXCAVATE. IN CASE LOOSE SOIL AND/OR AIR -VOIDS ARE FOUND NEAR BASE OF NEW FOOTING CONSTRUCTION, REMOVE AND BACK -FILL WITH LEAN MIX CONCRETE UNDER PRESSURE (F'C=1000PSI) TO PROVIDE A SOUND BEARING BASE OF NEW CONSTRUCTION. 4. REPORT TO ENGINEER OF RECORD IN CASE NEW FOOTING CONSTRUCTION CONFLICTS WITH EXISTING UNDERGROUND CIVIL LINES. 5. SUBGRADE FOR FOOTINGS AND SLAB ON GRADE SHALL BE PREPARED PER THE GEOTECHNICAL GUIDANCE. 6. SEE GENERAL NOTES AND SPECIAL INSPECTIONS ON S1.0 FOR ADDITIONAL INFORMATION. FRAMING NOTES 1. GC TO FIELD VERIFY LAYOUT OF EXISTING FLOOR FRAMING AND ELEVATIONS AS SHOWN IN PLAN. REPORT TO ENGINEER OF RECORD IN CASE OF ANY DISCREPANCY. 2. ALL EXPOSED STEEL FRAMING AND CONNECTION HARDWARES TO BE HOT DIPPED GALVANISED. 3. SEE THE GENERAL NOTES AND SPECIAL INSPECTION ON SHEETS S1.0 FOR ADDITIONAL INFO. STL PLATEFORM LEVE t 24' 9 1/2" GRADE LEVEL 0'-0 �W rer -43 aW71, (I.1) .L+ (52.42I' ) r 3495s'Sg` eA6.2Y (East) 955" ^ 321t) Publ'ie Aec vy k UL�I'�[y Euvemeril ✓ CJ1 10' P.U.E. I cen144hydrant existing !re hd ant end water line 183.80' WORK AREA Lot 2A 2.610 AE. 328 27 KEY PLAN Block --•7789°59•48"W •'•• mg REVISION DATE PSM CONSULTING ENGINEERS -0 7614 195TH SW, SUITE 201 EDMONDS, WA 98026 P: 206.622.4580 www.psm-engineers.com Ocean Beauty Seward Condenser 601 PORT AVENUE SEWARD, ALASKA SHEET CONTENTS: FOUNDATION PLAN, PLATFORM FRAMING PLAN AND FRAMING ELEVATIONS JOB No. 22113-003 DWN BY: HP CHKD BY: PSM DATE: 10/24/2024 SHEET No. S2.0 27 Site Plan Graphic *Created by staff to assist the Commission in their review **Not to scale. Building location on plat is approximate 1 1} Dept. of Hwys. Mon. \ i 0. ^ G 0 ° , p i +• G+ ,r\;(., N z 9 �n 0) \\'(L1) c> (52.42') •C'" •589°59'58 u.t7' n (East) ` 89 59'58" N I ^ (Last) Public Access & Utility Easernenl 183.80' J 10' P.U.E. centered on existing fire hydrant and water line uu_� P.U.E. '42 135 ,L0 Lot 2A 2.610 Ac. 12 5' Block 328.07 ,j w 0 0 0) / 6‘ 65 T—Dock Street 60.00' -00 O REFRIGERATION LAYOUT N89°59'48"W N89 59 48 W 11,1541 lorvs — — Loading dock space where the condenser stand would be placed 28 Dept. of Hwys. Mon. OD rn 0 C.0 I L a leV a�C" o � o � � I QT _r_ ititi,N, Vi Q 0_ \ NORTH i o. 4/1 LE). i Leirer Rd. cA- N ro a) SOO°00'07"W Lri Public: No. Bearing Distance (L1) (North) (7.00') No. Delta Radius Arc Length 31.42' Chord Length 28.29' Chord Bearing N44 59 57 W C1 90 00 09 20.00' (C1) (90°00'00") (20.00') (31.42) C2 73°13'52" 68.00' 86.91' 81.12' S53°23'06"E C3 05°13'38" 1879.86' 171.50' 171.44' N74°14'44"E (C3) (05°13'38") (1879.86') (171.50') C4 09°58'41" 1909.91' 332.61' 332.19' N71°51'54"E 3C4>' #10°00'45'1 #1909.86' #333.75' #333.331 #N71°42'38"Ei Dept. of Hwys. Mon. (L1) S8959'58"W (East) 89 59'58" (Last) Access Sc Utility Easement 183.80' 77-7.///777 ///7 /77i_LL/i7r�/ VOWMAT, 4@& potriv- 10' P.U.E.J centered on existing fire hydrant and water line 4�D�p U.E- _ Lot 2A L a) o 2,610 Ac. o c a) o 0 Biock 100.9' NOTES: 1) Development of these lots is subject to the City of Seward's zoning regulations. 2) A 10 ft. utility easement is reserved juxtaposed to the Rights - of -Way. No permanent structure shall be constructed or placed within a utility easement which would interfere with the ability of a Utility to use the casement. 3) No private access to State maintained ROW's permitted unless approved by the State of Alaska Deportment of Transportation. 4) Lots within this subdivision may be located within a designated flood hazard area, development must comply with Chapter 21 of the Kenai Peninsula Borough code of ordinances. A survey to determine the elevation of the property may be required prior to construction. 5) "WASTEWATER DISPOSAL: The Alaska department of Environmental Conservation has reviewed plans for this subdivision's wastewater disposal, and approves this subdivision for platting. Subject to any noted restrictions, The Alaska Department of Environmental Conservation approves this subdiyjsion for putting." signature E-EA title z/17/_9(7, date W 1 12.5' P.U.E. ffi 328.07' — — — N89°59'48"W `4()Qc CERTIFICATE OF SURVEYOR I hereby certify that; I am properly registered and licensed to practice land surveying in the State of Alaska, this plat represents a survey made by me or under my direct supervision, the monuments shown hereon actually exist as described, and all dimensions and other details are correct to the normal standards of practice of land surveyors in the State of Alaska. / s I) rw et.. / 11 G REGISTRATION No. DATE REGISTER AND SUR YOR 1.S "A 5 L N89°59'48'W , 1150.00' — Lf 1 (41.10) _ 61.65 s 0 z I\ ,,60.00' 5,r1D,©r 4 CLI • -D E. BAKER 0 01 No. LS-5152 "P `SSIONP; = ,'a _ Bass of Bear 576° 43' 23 / 0, P.U. 2,137 Ac. qt,-a8 RECORDED SCILIOICI REC. DIST. DATE: 19gb TIME: Pi_M REQUESTED BY: INTEGRITY SURVEYS 605 SWIRES DRIVE KENAI, ALASKA 99611 62, \ 10' P.U.E. -' centered on existing overhead electric line 10' Waterline Easement 268.97' 821.76' r LEGEND: MONUMENT (found this survey) • 5/8" REBAR (found this survey) O 5/8" REBAR (set this survey) A PK Nail (found this survey) A PK Nnil (set this survey) 2" ALCAP LS #3753 (found this survey) P.U.E. Public Utility Easement ( ) RECORD DATUM - Marina Subd. - Block 2 Plat # 89-10 SRD RECORD DATUM - Seward Industrial Park Plat # 73-349 SRD FORMER SUBDIVISION ENCROACHMENT INTO FEDERAL TIDELANDS Portion of Utility Easement being vacated by this plat MHW & Flood limits 1 4 `7 3' dated 19 Moy, 1981 co 0 0 0 w 0 _ 3.860 Ac. Public Parking and Access Easement S89°59'15"W 134.46' 0� N00°01'43"E 19 ❑ 0 ❑ O a 1 33 cC T1N • T1S SEWARD w 4 CITY OF SEWARD g VICINITY MAP 16 1" = 1 MILE 34 �. o BASE � 3//! THIS 10 cs-) 13o - (I) LINE CERTIFICATE of OWNERSHIP and DEDICATION I HEREBY CERTIFY THAT WE ARE THE OWNER(S) OF THE REAL PROPERTY SHOWN AND DESCRIBED HEREON AND THAT WE HEREBY ADOPT THIS PLAN OF SUBDIVISION AND BY OUR FREE CONSENT DEDICATE ALL RIGHTS -OF - WAY AND PUBLIC AREAS TO PUBLIC USE AND GRANT ALL EASEMENTS TO THE USE SHOWN. Ronald A. G•/ini, City Manager City of Sew. d P. 0. Box 167 Seward, Alaska 99664 NOTARY'S ACKNOWLEDGEMENT SUBSCRIBED AND 1996 FOR P WORN BEFORE yiE THIS 2716 DAY OF 4/41Praii4-, N4LD g e7/N/ LICALASKA COMMISSION EXPIRES 7 OFFICIAL SEAL STATE OF ALASKA YVETTE G. WELSH ((, NOTr.RY PUBLIC LESSEE CERTIFICATE I HEREBY CER I IF Y I HA I WE ARE IHL LESSEE(S) WI 1 HIN LO I S 2A AND ,SA SHOWN HEREON AND THAT WE HEREBY APPROVE THIS SUBDIVISION. G Melody Jorcan, eward Plant Manager Icicle Seafoods, Inc., an Alaskan Corporation P. O. Box 8 Seward, Alaska 99664 NOTARY'S AC'<NOWLEDGEMENT SUBSCRIBED AND SWORN BEFORE ME THIS (To DAY OF ecerh' beA- 1996 FOR He Ioci j "TOidam m.at2c Cd.d%chRA.n) N TARY PUBLIC FOR ALASKA MYCOMMISSION EXPIRES 2128111 PLAT APPROVAL THIS PLAT WAS APPROVED BY THE KENAI PENINSULA BOROUGH PLANNING COMMISSION AT THE MEETING OF KENAI PENINSULA BOROUGH AUTHORISE 64CIAL KPB FILE No. 95-075 June 12, 1995 ijov. i3/9'?L,, Subd, Marinct Block 2 Reptat A Re plat of Lots 2— 4 Marina Subdivision Block 2 Plat #89 10 S. R. D. Located within the NW1/4 & NE1 / 4 of Section 3, T1S, R1W, S.M., City of Seward, Seward Recording District, Kenai Peninsula Borough, Alaska. Containing 9.030 Acres INTEGRITY SURVEYS 605 Swires Drive Kenai, Alaska 99611-8363 SURVEYORS PHONE — (907) 283-9047 PLANNERS FAX --- (907) 283-9071 JOB NO: 94131 DRAWN: CB SURVEYED: July 1994 - June 1995 SCALE: 1" = 50' FIELD BK: 94-8, Pg 51-67 PROJECT: 94075 29 AFFIDAVIT OF POSTING PUBLIC HEARING NOTICE 1, ��1� +� k t-\ , hereby certify that I have posted a Notice of Public Hearing, as prescribed by Seward City Code 15.01.040 for the property located at Marina Subdivision, Block 2 Replat, Lot 2A, Block 2; physical address 601 Port Avenue, the owner of which have petitioned for a Public Hearing for a Variance from Seward City Code 15.10.220 Development Requirements to exceed the 34' building height regulation to install a condenser unit on top of the existing building. The property is located within the Harbor Commercial (HC) zoning district. The notice was posted on Janu al 21 202_5 , which is 171 days prior to the public hearing on this petition. I acknowledge this Notice must be posted in plain sight, maintained and displayed until all public hearings have been completed. 54- Affirmed and signed this 21 day of JanL lki , 2025. J II Signature 30 CITY OF SEWARD, ALASKA AFFIDAVIT OF MAILING PUBLIC HEARING NOTICE , upon oath, deposes and states: That she is employed in the Community Development Office of the City of Seward, Alaska; and that on Januca� \ Lp 2-O-Z 5 she mailed a Notice of Public Hearing to the real property owners within a 300-foot periphery of Marina Subdivision, Block 2 Replat, Lot 2A, Block 2; physical address 601 Port Ave, as prescribed by Seward City Code 15.01.040/16.01.015. Affirmed and signed this day of JC u4 \ 2025. e)/_e, Planning and Zoning Agenda Statement Meeting Date: February 4, 2025 To: Planning and Zoning Commission Through: Daniel Meuninck, Community Development Director From: Applicant Agenda Item: Resolution 2025-005, of the Planning and Zoning Commission of the City of Seward, Alaska, Granting a Conditional Use Permit to Chugachmiut to construct and operate a pharmacy drive-thru window at the new Chugachmiut Regional Health Center on Fort Raymond Subdivision Replat No 1, 2022 Addition, Lot 7A-2; Located at 704 Aspen Lane; Within an Auto Commercial (AC) Zoning District Background and justification: Chugachmiut has applied for a Conditional Use Permit (CUP) from the Seward Planning and Zoning Commission to construct and operate a pharmacy drive-thru window at the new Chugachmiut Regional Health Center currently being constructed at 704 Aspen Lane. The property is located within the Auto Commercial (AC) zoning district. A health clinic is allowed outright in the AC zoning district. However, a drive-in facility, defined as "any portion of a building or structure which by design permits customers to receive services, obtain goods or be entertained while remaining in their motor vehicles," requires a CUP in the AC zoning district. Pharmacy drive-thru windows provide a contactless service option to individuals who may be sick and contagious as well as to individuals with weakened immune systems who are susceptible to infectious disease. A pharmacy drive-thru window improves accessibility for individuals with mobility concerns and challenges such as the elderly, pregnant women, people with disabilities, and parents with young children in the car to receive prescribed medication without needing to leave their vehicles. The proposed drive-thru window can be accessed either by entering the property from the Seward Highway or Aspen Lane. Only one-way traffic will be allowed on the north side of the building where the pharmacy drive-thru window will be operated. The applicant has complied with all the public hearing requirements of Seward City Code § 15.01.040. Regarding conditional uses, Seward City Code § 15.10.320 states, "It is recognized that there are some uses which may be compatible with designated principal uses in specific zoning districts provided certain conditions are met. The conditional use permit procedure is intended to allow flexibility in the consideration of the impact of the proposed use on surrounding property, and the application of controls and safeguards to assure that the proposed use will be compatible with the surroundings. The commission shall permit this type of use if the conditions and requirements listed in this chapter (Title 15) are met." 32 Prior to granting a conditional use permit, the Commission shall establish that the use satisfies the following conditions as listed in SCC § 15.10.320(D): 1. The use is consistent with the purpose of this chapter and the purposes of the zoning district; 2. The value of the adjoining property will not be significantly impaired; 3. The proposed use is in harmony with the Comprehensive Plan; 4. Public services and facilities are adequate to serve the proposed use; 5. The proposed use will not be harmful to the public safety, health or welfare; 6. Any and all specific conditions deemed necessary by the commission to fulfill the above - mentioned conditions shall be met by the applicant. These may include but are not limited to measures relative to access, screening, site development, building design, operation of the use and other similar aspects related to the proposed use. Surrounding Land Use and Zoning: Development Requirements: Seward City Code Title 15 does not have specific development requirements for a drive-thru window. The only requirements are the setback, building height, and lot coverage requirements for the entire building, which have been met. Surrounding Land Use: The property to the west is the American Legion Cemetery and Seward Parks and Recreation warehouse and is zoned Institutional. The property to the south is the Seward Chamber of Commerce and is zoned Auto Commercial. The property to the north is vacant but will be used for the future Public Works facility and is zoned Auto Commercial. The property to the east is across the Seward Highway and is owned by the Alaska Railroad and zoned Industrial. Floodplain status: According to the Kenai Peninsula Floodplain Map, the property is not located within a FEMA-mapped floodplain. Utilities: City water, sewer, and electricity are connected to the property. Parking: A drive-thru window does not require a specific number of parking spaces. Providing a drive-thru pharmacy window may alleviate parking congestion as individuals will not need to park and walk into the clinic to pick up a prescription. However, the clinic is required to have a certain number of parking spaces, which was reviewed and approved during the building permit process. Comprehensive and Strategic Plan Consistency Information This legislation is consistent with (citation listed): Comprehensive Vol 1, Chapter 2.2.6 "We value effective, accessible, and affordable Plan: healthcare." Vol 1, Chapter 3.7.1.5 — "Support expansion and modernization of health care facilities." 33 Vol 1, Chapter 3.7.1.8 — "Support and develop opportunities for individual and community health improvement." Strategic Plan: N/A Department Comments No Comment N/A Building Department X Fire Department X Public Works Department X Harbor Department X Police Department X Electric Department X Property owners within three hundred (300) feet of the location of the proposed Conditional Use Permit action were notified of this public hearing. Public notice signs were posted on the property and all other public hearing requirements of Seward City Code § 15.01.040 were complied with. At the time of this publication the Community Development Department has not received public inquiries regarding the proposed Conditional Use Permit. If any correspondence is received after publication of this agenda statement, it will be submitted to the Planning and Zoning Commissioners for their review. Recommended Conditions 1. The applicant shall work with the building official through the building permit process to address any requirements per International Fire Code and International Building Code. 2. Signage shall be placed on the property indicating one-way traffic on the driveway going to and leaving the drive-thru window. 3. Per Seward City Code § 15.10.325(f). an approved CUP shall lapse six months from the date of approval if the use for which the permit was issued has not been implemented or a building permit obtained. The Commission may grant a six-month extension upon finding that circumstances have not changed sufficiently since the date of initial permit approval. 4. Modification of final approval of a conditional use permit may, upon application by the permittee, be modified by the Planning and Zoning Commission: a. When changed conditions cause the conditional use to no longer conform to the standards for its approval. b. To implement a different development plan conforming to the standards for its approval. c. The modification plan shall be subject to a public hearing and a filing fee set by City Council Resolution. 34 Recommendation The proposed use is permittable through the Conditional Use Permit process, which allows the Commission the opportunity to ensure that the use is consistent with the purpose of the zoning district and surrounding land uses, is in harmony with the Comprehensive Plan, and will not be harmful to the public safety, health, or welfare. 35 Sponsored by: Applicant Public Hearing: February 4, 2025 CITY OF SEWARD, ALASKA PLANNING AND ZONING COMMISSION RESOLUTION 2025-005 A RESOLUTION OF THE PLANNING AND ZONING COMMISSION OF THE CITY OF SEWARD, ALASKA, GRANTING A CONDITIONAL USE PERMIT TO CHUGACHMIUT TO CONSTRUCT AND OPERATE A PHARMACY DRIVE-THRU WINDOW AT THE NEW CHUGACHMIUT REGIONAL HEALTH CENTER ON FORT RAYMOND SUBDIVISION REPLAT NO 1, 2022 ADDITION, LOT 7A-2; LOCATED AT 704 ASPEN LANE; WITHIN AN AUTO COMMERCIAL (AC) ZONING DISTRICT WHEREAS, Chugachmiut has applied for a Conditional Use Permit (CUP) from the Seward Planning and Zoning Commission to construct and operate a pharmacy drive-thru window at their new healthcare facility located at 704 Aspen Lane; and WHEREAS, the property is in an Auto Commercial (AC) zoning district; and WHEREAS, a health clinic is allowed outright in the AC zoning district; and WHEREAS, a drive-in facility requires a CUP in the AC zoning district; and WHEREAS, a drive-in facility is defined as "any portion of a building or structure which by design permits customers to receive services, obtain goods or be entertained while remaining in their motor vehicles"; and WHEREAS, a pharmacy drive-thru window provides a contactless service option to individuals who may be sick and contagious as well as to individuals with weakened immune systems who are susceptible to infectious disease; and WHEREAS, a pharmacy drive-thru window improves accessibility for individuals with mobility concerns and challenges such as the elderly, pregnant women, people with disabilities, and parents with young children in the car to receive prescribed medication without needing to leave their vehicles; and WHEREAS, the property is located along the Seward Highway and has two driveway entrances to the facility, one directly on the Seward Highway, and the other on Aspen Lane; and WHEREAS, only one-way traffic will be allowed on the north side of the building where the pharmacy drive-thru window will be operated; and WHEREAS, the property to the west is zoned Institutional and is utilized for the American Legion Cemetery and the City of Seward Parks and Recreation warehouse; and 36 CITY OF SEWARD, ALASKA RESOLUTION 2025-005 WHEREAS, the property to the south is zoned Auto Commercial, and utilized for the Seward Chamber of Commerce; and WHEREAS, the property to the north is zoned Auto Commercial and currently vacant, but is planned to be utilized for the new Public Works facility; and WHEREAS, the property to the east is located across the Seward Highway, is zoned Industrial and utilized by the Alaska Railroad; and WHEREAS, Seward City Code § 15.10.320 recognizes that there are some uses that may be compatible with designated principal uses in specific zoning districts provided certain conditions are met; and WHEREAS, the applicant has complied with all of the public hearing requirements of Seward City Code § 15.01.040; NOW, THEREFORE, BE IT RESOLVED by the Seward Planning and Zoning Commission, that: Section 1. The Commission finds that the proposed use satisfies the following conditions as specified in SCC §15.10.320.D. A. The use is consistent with the purpose of this chapter (the Seward Zoning Code) and the purposes of the zoning district. B. The value of the adjoining property will not be significantly impaired. C. The proposed use is in harmony with the Seward Comprehensive Plan. D. Public services and facilities are adequate to serve the proposed use. E. The proposed use will not be harmful to the public safety, health, or welfare. Section 2. Any and all specific conditions deemed necessary by the Commission to fulfill the above -mentioned conditions shall be met by the applicant. Approval of the CUP shall be subject to the following conditions: 1. The applicant shall work with the building official through the building permit process to address any requirements per International Fire Code and International Building Code. 2. Signage shall be placed on the property indicating one-way traffic on the driveway going to and leaving the drive-thru window. 3. Per Seward City Code § 15.10.325(f). an approved CUP shall lapse six months from the date of approval if the use for which the permit was issued has not been implemented or a building permit obtained. The Commission may grant a six-month extension upon finding that circumstances have not changed sufficiently since the date of initial permit approval. 4. Modification of final approval of a conditional use permit may, upon application by the permittee, be modified by the Planning and Zoning Commission: 37 CITY OF SEWARD, ALASKA RESOLUTION 2025-005 a. When changed conditions cause the conditional use to no longer conform to the standards for its approval. b. To implement a different development plan conforming to the standards for its approval. c. The modification plan shall be subject to a public hearing and a filing fee set by City Council Resolution. Section 3. The Planning and Zoning Commission finds that the proposed use, subject to the above conditions satisfies the criteria for granting a conditional use permit provided the conditions listed on Section 2 are met by the applicant before a certificate of occupancy is granted, and authorizes administration to issue a conditional use permit to Chugachmiut to construct and operate a drive-thru pharmacy window at the Chugachmiut Regional Health Center located at 704 Aspen Lane. Section 4. The Planning and Zoning Commission finds that adherence to the conditions of this permit is paramount in maintaining the intent of Seward City Code Section 15.10.320: Conditional Use Permits. A Conditional Use Permit may be transferred to a new owner per §15.10.320(G), in which case the new owner will be required to maintain conformance to the conditions of the permit. Section 5. Administration shall periodically confirm the approved conditional use conforms to the standards of its approval. Nonconformance to these above stated conditions shall be grounds for revoking the Conditional Use Permit. Section 6. This resolution shall take effect 10 days following its adoption. PASSED AND APPROVED by the Seward Planning and Zoning Commission this 4th day of February, 2025. AYES: NOES: ABSENT: ABSTAIN: ATTEST: Kris Peck - City Clerk - (City Seal) THE CITY OF SEWARD, ALASKA Carol Griswold, Chair 38 Context Map Single-family Residential Multi -family Residential Auto Commercial Industrial Institutional Park A 200 feet Conditional Use Permit Application Property Map RES 2025-005 - Granting a conditional use permit to construct and operate a pharmacy drive-thru window Location: 704 Aspen Lane Parcel #: 14502628 39 CITY OF SEWARD P. U. Box 167 410 Adams Street Seward, Alaska 99664 Community Development 907.224.4048- Director 907,224.4020- Plainer 907.224.4049- Planning Assistant CONDITIONAL USE PERMIT APPLICATION This completed application is to be submitted to the Community Development Department no later than four (4) weeks in advance of the next regularly scheduled Planning and Zoning Commission meeting. Regular meetings are held the first Tuesday of each month. The application must be accompanied by the $350 nonrefundable filing fee. In addition, please provide an as -built survey if the property has been developed or a scaled site plan with elevations if the property is undeveloped. Applicant: Chugachmiut Address: 1840 Bragaw St. Suite 110, Anchorage, AK 99508 Telephone Number: (907) 441-8565 Email: kelley@chugachmiut.org Property Owner (if other than applicant): Address: Telephone Number: Email: Property Description Address: 704 Aspen Lane Lot Size: 3.31 Lot: 7A-2 dock: Subdivision: T ON R 01W SEC 34 Seward Mandlan SW 2022012 FORT RAYMOND Kenai Peninsula Borough Tax Parcel ID Number: 14502628 Development Information What structures are on the property? 1 Building How is the property being used? Regional Health Center What Is the proposed use of the property? Provide Healthcare What is the development timeline? Completed by 03/31/25 Please note that prior to the Seward Planning and Zoning Commission granting a Conditional Use Permit, it shall be established that the proposed use satisfies the following conditions of Seward City Code 15.10.320 (See the attached pages for specific City Code requirements) 40 A) The proposed use is consistent with the requirements of the Seward Zoning Code and the designated zoning district. Please describe the use. Auto' Commercial (AC) Nrtsuiip1io1is quickly and conven+entiy witliuul ieavinj therr car, offenng a ftrot, hassle -free experience, particularipforQtok„ Ynvbt , isSue.5 o T�►i�el�' �'►l neiwt A SO ri16WI iVC,'11COI ' Vi 1S ank Mier kk,t 4k 14a1 rcatt cei B) Describe any impacts to the adjoining properties and how property values may be affected. C) How is the proposed use consistent with the Seward Comprehensive Plan? Explain. You can view the plan at: htto:llwww.cityofseward.us! e-use TOIIOW5 Vol 1 d1 ru Vu pier ns� Speuifieally healI.huare, cuiritnuttily parlnpb, aiud euunonnicat devek prnerif. D) Describe I Ilst the public services and facilities that will serve the proposed use. (i.e., roads, utilities.) Water, sewer, electrical, policing, and fire road accessed by Seward Highway and Aspen lane. E) The proposed project or use must not be harmful to the public health, safety and welfare. Describe any mitigation measures that may be needed to protect the public health, safety and welfare. N/A F) Include building elevation plans and a site plan, drawn to scale. The site plan should include: 1) Property dimensions 17 2) Location and dimensions of existing and planned buildings 3) Parking configuration See previous submitted building plains 4) Driveways and access on file with building department. 5) Natural features 6) Other pertinent information El 41 I hereby certify that the above statements and other information submitted are true and accurate to the best of my knowledge and that I have the following legal interest in the property: Owner of record I understand that this item will be scheduled for action only if all application materials are submitted not less than three weeks in advance of the next regularly scheduled Planning and Zoning Commission meeting. Regular meetings are held the first Tuesday of every month. Applicant Signature: Property Owner Signature: Enclosed: $350 Payment n Dimensioned plot plan 1 drawings Other: 1<rct----C) On file already with building department. 42 D DRAWING FILE II II II II II II - ENCLOSED GENERATOR ss ss ss SS (INTEGRAL TANK) FENCE SEWER SERVICE (SEE SHEET U11) — —> —> —> -> - COLLECTION OF RECYCLEABLES •4 DUMPSTER ENCLOSURE (SEE ARCHITECTURAL) SS ONE-WAY SE - TRANSFORMER SS -ssS LOT 7A-1 SS EWER MAIN _ EV CHARGER-------..4 II II II II II II II II I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I � I I I I I I o ASPEN LANE RAMP FOR AMBULANCE PICK UP HEATING OIL TANK //////////////// CITY OF • SEWARD PARKS AND / RECREATION BUILDING I I I I I I I I I I I I I I I I OVERALL SITE PLAN PHARMACY WINDOW NEW 1-STORY BUILDING ENTRY TO WAITING ROOM LOT 5 TB06 O SCREENING FENCE% ASPEN LANE -CANOPY PROPOSED FIRE HYDRANT (SEE SHEET U12) SEE LANDSCAPE PLAN SS LSTORM WATER POND 1 EXISTING PATHWAY EXISTING FIRE HYDRANT PEDESTRIAN / BICYCLE CONNECTION TO PATH REPAVE/REGRADE PATH AND CURB AT OLD DRIVEWAY i N N SIGN NOTES 1. TEXT IN PARENTHESES IS INFORMATIONAL AND SHOULD NOT BE PRINTED ON THE SIGN. R-X DESIGNATIONS ARE PER MUTCD. 2. PROVIDE A SUBMITTAL, FOR CUSTOM SIGNS, (NOT PER MUTCD) FOR OWNER REVIEW PRIOR TO PURCHASING. 3. SEE DETAIL C1/C50 FOR SIGN DETAIL. PLAN NORTH SCALE: 1" = 30' 1 2 3 0' 30' 60' SIGN TABLE # DESCRIPTION DIRECTIONAL ARROW SIZE 01 PATIENT PARKING / DROP-OFF (FACING SOUTHWEST) 1 12"X18" AMBULANCE PICK UP (FACING SOUTHWEST) 12"X18" PHARMACY DRIVE-THRU (FACING SOUTHWEST) 1 12"X18" EXIT 1 12"X18" 53 WRONG WAY (R5-1A) 24"X30" 0 WRONG WAY (R5-1A) 24"X30" 0(FACING PATIENT PARKING / DROP-OFF (FACING SOUTHWEST) 12"X18" PHARMACY DRIVE-THRU SOUTHWEST) 1 „ 12"X18" PATIENT PARKING / DROP-OFF (FACING NORTHEAST) 12"X18" y e PHARMACY DRIVE-THRU (FACING SOUTH) 1 12"X18" EXIT (FACING SOUTH) 12"X18" PATIENT PARKING / DROP-OFF (FACING EAST) 12"X18" PHARMACY DRIVE-THRU (FACING EAST) 12"X18" y 57 STOP (R1-1) 24"X24" Ss WRONG WAY (R5-1A) 24"X30" e WRONG WAY (R5-1A) 24"X30" 0 NO PARKING ANYTIME (R7-1) 12"X18" 0, FACILITIES MAINTENANCE PARKING ONLY 12"X18" 0 RESERVED PARKING (R7-8) 12"X18" VAN PARKING (R7-8A) 12"X6" e RESERVED PARKING (R7-8) 12"X18" 0 RESERVED PARKING (R7-8) 12"X18" 0 RESERVED PARKING (R7-8) 12"X18" PATIENT DROP-OFF ONLY - NO PARKING 12"X18" e ELDER PARKING 12"X18" ELDER PARKING 12"X18" ®2 ELDER PARKING 12"X18" e ELDER PARKING 12"X18" ®2 ELDER PARKING 12"X18" 0 NO PARKING FIRE LANE (R8-31 WITH ARROWS) 18 X24„ NO PARKING FIRE LANE (R8-31 WITH ARROWS) 18"X24" 0 ELECTRIC VEHICLE PARKING ONLY WHILE CHARGING 12"X18" O ELECTRIC VEHICLE PARKING ONLY WHILE CHARGING 12"X18" O ELECTRIC VEHICLE PARKING ONLY 12"X18" O ELECTRIC VEHICLE PARKING ONLY 12"X18" O ELECTRIC VEHICLE PARKING ONLY 12"X18" e ELECTRIC VEHICLE PARKING ONLY 12"X18" 4 ARCHITECTS ALASKA AK Corp. Authorization AECC561 900 W. 5th Avenue, Suite 403 Anchorage, Alaska 99501 907.272.3567 191 E. Swanson Avenue, Suite 203 Wasilla, Alaska 99654 907.373.7503 www.architectsalaska.com tt ■ ■ ENTERPRISE ENGINEERING, INC. 3601 C STREET, STE 650 ANCHORAGE, AK 99503 TEL. (907) 563-3835 LICENSE #AECC651 SEWARD, ALASKA IF SHEET IS LESS THAN 22" x 34" IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY Revisions No. Description Date Drawn by RPP Date 10/05/2023 Checked CAB Job No. 10033 Sheet Contents OVERALL SITE PLAN Sheet No. 43 BIM 360://22073.01 Chugachmuit Regional Health Clinic/22073.01 Chugachmiut Regional Health Clinic.rvt Plot Date Time: 7/8/2023 6:22:11 PM c A 2 3 4 CANOPY, AMBULANCE PARKING 20' - 9" 9'-10" 10'-4" 8'-6" 8'-6" 8' - 10" 8'-11" 12' - 2 1 /2" 1808-2 RECEIVING, MATERIAL, HANDLING 'I' 181 RECYCLING STORAGE N MED GAS ob 1814C GROUP 1802-1 BREAK ROOM W4A 1808-1 1810-i CASE \ MANAGER (W1k 1810 1 VEST/ANTE 1816-1 1818D W1A 5'-5"T co SOILED UTILITY 1818A INVENTORY W1A 1914-1 CONTROL SPECIALIST PROPERTY & STORAGE SUPPLY Al DIMENSION FLOOR PLAN A101 ; 1/8" = 1'-0" 22' - 10" 1818B SOCIAL SERVICES 5' - 2 1 /2" CHAP CLINICAL SUPERVISOR 8'-0" 1815-1 BEHAVIORAL HEALTH MA/CHAP + TEAM 1809A ADDICTION COUNSEL 1809B-1 MA/CHAP + TEAM 1809B WAIVE TEST L'l 1817-1 o L HOUSEKEEPING CLINICAL ® 1817 STORAGE 1819-1 ALIGN WALLS CLEAN UTILITY PROVIDER TRAVEL OFFICE 8'-0" CORRIDOR PROVIDER PROVIDER 8'-0" 8'-0" PH NURSE 5'-51/2" PHN SUP --- PROCEDURE ALIGN WA LS 5'-8" 1606-1 EXAM/EKG CANOPY NUTRITION PHLEB 8'-0" j 8'-4" 1—--- EXAM/OPTOM ED/CONF 2 1903-2 q2'-11" 12' W7A MIN. CLR. VEST 18" MIN. N N O W1A ! CHK OUT 1603A BILLING SUPPLY 1603C PUBLIC FEMALE HEALTH COACH/INJURY PREVENTION BOILER 1108-2 CONTROL, CANOPY PHARMACY 1105F STORE, PHARMACY 5'-63/4" PHARMACY RECEIVING 1105A 6' - 1 1/4" 1226 1102D RECEPTION 1603B 8' - 10 1 /2" CONSULT PRC HEALTH CLERK CONSULT PUBLIC MALE 4' - 1 15/16" 1N 0" PROCEDURE 1102C 02 11 8' 2 17/256" 1303-1 10'-0" 10'-0" OPEN PROC OPEN PROC OPEN PROC I OPEN PROC 1304 J 1306 1308 1 1310 25.000 DENTAL ADMIN 10' - 6 1 /2" RECORD STOR UNIT SUP 1204B w8 PRACTICE HEALTH MANAGER SERVICES DIRECTOR PRIMARY CARE WAITING 1 1 i 1101-2 VEST 1102B COMMON WAITING 1102A \I ALIGN WALLS UNIT SUP 11'-81/2" 9'-0" DUP EQ & SUPPLY 1206B N CORRIDOR i 3 IT/CPU WKRM DENT LAB PANOREX MED REC / PROVIDER TOILET STERILE 1311 1404- 1406-1 0 REC TEC 1209B EMR TR STAFF TLT/SH 1218B-1 1218A 11'-5" TEAM WKST 1316-1 14'-07/16" STAFF 14V5AF1 BUNK INJURY PREVENTION OFFICER 1218C EMPLOYEE LOUNGE . 1220-2 VEST 1220 0 c31 EMS TRAINER OFFICE 0 2' 4' 8' >- o_ 0 z 0 r o CV co M 16' 4 AECC561 Alit ARCHITECTS ALASKA 900 W. 5th Avenue, Suite 403 Anchorage, AK 99501 907.272.3567 191 E. Swanson Avenue, Suite 203 Wasilla, AK, 99564 907.373.7503 www.architectsalaska.com Revisions No. Description Date Drawn by RHOWMINE Date 7/7/2023 Checked H E N R I Job No. 22073.01 Sheet Contents FIRST FLOOR DIMENSION PLAN Sheet No. A101 44 U U Ta 0 .5) a) cC 0) U Clinic/22073.0 BIM 360://22073.01 Chugachmuit Regional Hea Plot Date Time: 7/8/2023 6:22:34 PM C A PHENOLIC PANELS 1 2 EXTERIOR CANOPY i•� _ I IyII I I I I I I�I�I1I „I I:r j jjet �I"0014141 re SCHE UL D NORTH ELEVATION 1 /8" = 1 '-0" STANDING SEAM METAL CANOPY ROOF EXTERIOR WALL MOUNTED SIGN COLUMNS; REFER TO STRUCTURAL BLACK METAL FISH ON STANDOFFS PHENOLIC PANELS STONE VENEER WAINSCOT Al EAST ELEVATION STONE VENEER WAINSCOT r ":477.1 1,4 DIAMOND SHAPED METAL SIDING DIAMOND SHAPED METAL SIDING A504y CURTAIN WALL BLACK METAL FISH AS SCHEDULED ON STANDOFFS EXTERIOR CANOPY, SEE D3/A203, FOR PATT DOOR AS SCHEDULED DOOR AS SCHEDULED HORIZONTAL CORRUGATED METAL SIDING 3 WINDOWS AS SCHEDULED STONE VENEER WAINSCOT PHENOLIC PANELS STANDING SEAM METAL ROOF PANELS CURTAIN WALL AS SCHEDULED HORIZONTAL CORRUGATED METAL SIDING CANOPY PATTERN, SEE D3/A203, TYP. DIAMOND SHAPED METAL SIDING A201 1 1/8" = 1'-0" 1 2 3 4 EXTERIOR ELEVATION NOTES 1. SEE SHEET A602 FOR TYPICAL EXTERIOR WALL ASSEMBLIES. 2. SEE SHEET A603 FOR WINDOW AND DOOR SCHEDULES. STONE VENEER WAINSCOT 4 PHENOLIC PANELS ARCHITECTS ALASKA 900 W. 5th Avenue, Suite 403 Anchorage, AK 99501 907.272.3567 191 E. Swanson Avenue, Suite 203 Wasilla, AK, 99564 907.373.7503 www.architectsalaska.com Revisions No. Description Date Drawn by RHOWMINE Date 7/7/2023 Checked H E N R I Job No. 22073.01 Sheet Contents EXTERIOR ELEVATIONS Sheet No. A201 45 1 0 U 0) S ro 0 Ta 0) CC Clinic/22073.0 BIM 360://22073.01 Chugachmuit Regional Hea c /D2 EXTERIOR PERSPECTIVE SOUTH ek,20 B B2 EXTERIOR PERSPECTIVE SOUTHWEST CORNER A204 A Plot Date Time: 7/8/2023 6:23:16 PM 1 A3 2 EXTERIOR PERSPECTIVE AT NORTHEAST CORNER 3 4 A204 2 3 4 ARCHITECTS ALASKA 900 W. 5th Avenue, Suite 403 Anchorage, AK 99501 907.272.3567 191 E. Swanson Avenue, Suite 203 Wasilla, AK, 99564 907.373.7503 www.architectsalaska.com Revisions No. Description Date Drawn by RHOWMINE Date 7/7/2023 Checked H E N R I Job No. 22073.01 Sheet Contents EXTERIOR PERSPECTIVE VIEWS Sheet No. A204 46 U U 0 S ro 0 Ta 0) cc Clinic/22073.0 BIM 360://22073.01 Chugachmuit Regional Hea Plot Date Time: 7/8/2023 6:23:24 PM A jh ROOF MI 24' - 6" ® LEVEL 2 15'-0" \305 SOCIAL SERVICES L15 J LALEVEL 1 0" jpi CRAWL SPACE 4'-9" cl BUILDING SECTION BEHAVIORAL HEALTH —1512- ADDICTION COUNSEL 1510 2 PH NURSE 1508 III III III III III R-1 PHN SUP A303 1105E 3 PROCEDURE OPEN PROC —1304— OPEN PROC =1306— II III III III III OPEN PROC . 1308J EW-2 OPEN PROC PROVIDER 4 TEAM WKST A302 / 1/8" = 1'-0" Al LkROOF 24'-6" LkLEVEL 2 15'-0" La LEVEL 1 MI 0„ I II II Il II II I VEST COR13IDOR 1808 1101 jpi CRAWL SPACE MIJ -4'-9" 14 ROOF 24'-6" LEVEL 2 15'-0" LEVELI 0" 11 CRAWL SPACE *. -4'-9„ B1 \ BUILDING SECTION r 1��i>t!i>t�ilri>fdWafi>�f�>tlifi>�1r�la►i*.fi>��i>t!i>t�P!_w_� III III III CORRIDOR CORRIDOR III A302 1/8" = 1'-0" C ' �'',ii'''''4'iii is 11 11 1` 1 1a �_ ;' 1� ► �� vG III e ,o 1i �i�i�i�0i�i�i�i�i�i�i�i�i�i�i�i�i�i�e,�i�i�i�i�i�i�i�i�i►e,�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�0e,�i��0i�i�i�iOO/=®i�i�i�i�i�i�i►�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�ODi�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�iVi�Oi�i�i�i�i�i�i►i�i�i�i�iO�i�i�i9�i�i�i�i�i�i�i�®i�i�i�I .�: a®i�®i�i� - II III III II BUILDING SECTION 1/8" = 1'-0" BREAK ROOM CORRIDOR 1801 I I I I I I I I I I I I CORRIDOR PROCEDURE 2005--- -- 1606 2 PRC HEALTH CLERK CONSULT 1602 PHLEB DENTAL CORRIDOR WAITING- 11226 1102C RECORD STOR UNIT SUP 1204E 3 DUP EQ & SUPPLY 1206B DENT EQUIP LAUNDRY 1218A LOUNGE III III III III 4 ARCHITECTS ALASKA 900 W. 5th Avenue, Suite 403 Anchorage, AK 99501 907.272.3567 191 E. Swanson Avenue, Suite 203 Wasilla, AK, 99564 907.373.7503 www.architectsalaska.com Revisions No. Description Date Drawn by RHOWMINE Date 7/7/2023 Checked H E N R I Job No. 22073.01 Sheet Contents BUILDING SECTIONS Sheet No. A302 47 CITY OF SEWARD, ALASKA AFFIDAVIT OF MAILING PUBLIC HEARING NOTICE l : \civc, V?)r-ov, ,r, , upon oath, deposes and states: That she is employed in the Community Development Office of the City of Seward, Alaska; and that on e i1 , 9-dZ she mailed a Notice of Public Hearing to the real property owners within a 300-foot periphery of Fort Raymond Subdivision Replat No 1, 2022 Addition, Lot 7A-2; Located at 704 Aspen Lane as prescribed by Seward City Code 15.01.040/16.01.015. Affirmed and signed this 0±-11 day ofJemikel 2025. AFFIDAVIT OF POSTING PUBLIC HEARING NOTICE I► �L" 1 ` "`Vrr\ � hereby certify that I have posted a Notice of Public Hearing, as prescribed by Seward City Code 15.01.040/16.01.015 on the property located at Fort Raymond Subdivision Replat No 1, 2022 Addition, Lot 7A-2; Located at 704 Aspen Lane on which the applicant has petitioned for a Public Hearing for a Conditional Use Permit to construct and operate a pharmacy drive-thru window at their health care facility, within an Auto Commercial (AC) Zoning District. The notice was posted on r C( 5 , which is days prior to the public hearing on this petition. I acknowledge this Notice must be posted in plain sight, maintained and displayed until all public hearings have been completed. --S-ctr\ Affirmed and signed this L day of , 2025 Signature 49 Planning and Zoning Agenda Statement Meeting Date: February 4, 2025 To: Planning and Zoning Commission Through: Daniel Meuninck, Community Development Director From: Applicant Agenda Item: Resolution 2025-006, of the Planning and Zoning Commission of the City of Seward, Alaska, Granting a Conditional Use Permit to The Tufted Puffin LLC to operate a drive-thru window to sell retail cannabis products and non -cannabis food and beverage items on Lot 1, Block 2, North Harbor Subdivision; Located at 408 Port Avenue; Within an Auto Commercial (AC) Zoning District Background and justification: The Tufted Puffin LLC has applied for a Conditional Use Permit (CUP) from the Seward Planning and Zoning Commission to operate a drive-thru window from their marijuana retail store located at 408 Port Avenue. The property is located within the Auto Commercial (AC) zoning district. A marijuana retail store is allowed outright in the AC zoning district. However, a drive-in facility, defined as "any portion of a building or structure which by design permits customers to receive services, obtain goods or be entertained while remaining in their motor vehicles," requires a CUP in the AC zoning district. The drive-thru window would be utilized to sell retail cannabis products as well as non -cannabis food and beverage items. A drive-thru window provides an option for individuals with mobility issues such as the elderly or those with disabilities to purchase these products without needing to exit their vehicles. The drive-thru window will be accessed by entering the property from Port Avenue. Only one-way traffic will be allowed on the side of the building where the drive-thru window will be operated. The applicant is aware they will be required to comply with specific regulations set forth by the Alaska Alcohol and Marijuana Control Office (AMCO) for operating a drive-thru window to sell retail marijuana products. The applicant has complied with all the public hearing requirements of Seward City Code § 15.01.040. Regarding conditional uses, Seward City Code § 15.10.320 states, "It is recognized that there are some uses which may be compatible with designated principal uses in specific zoning districts provided certain conditions are met. The conditional use permit procedure is intended to allow flexibility in the consideration of the impact of the proposed use on surrounding property, and the application of controls and safeguards to assure that the proposed use will be compatible with the surroundings. The commission shall permit this type of use if the conditions and requirements listed in this chapter (Title 15) are met." 50 Prior to granting a conditional use permit, the Commission shall establish that the use satisfies the following conditions as listed in SCC § 15.10.320(D): 1. The use is consistent with the purpose of this chapter and the purposes of the zoning district; 2. The value of the adjoining property will not be significantly impaired; 3. The proposed use is in harmony with the Comprehensive Plan; 4. Public services and facilities are adequate to serve the proposed use; 5. The proposed use will not be harmful to the public safety, health or welfare; 6. Any and all specific conditions deemed necessary by the commission to fulfill the above - mentioned conditions shall be met by the applicant. These may include but are not limited to measures relative to access, screening, site development, building design, operation of the use and other similar aspects related to the proposed use. Surrounding Land Use and Zoning: Development Requirements: Seward City Code Title 15 does not have specific development requirements for a drive-thru window. The only requirements are the setback, building height, and lot coverage requirements for the entire building, to which it complies. The building on the property was an existing structure when purchased and renovated for use as a marijuana retail store. Surrounding Land Use: The property to the west is across the Seward Highway is zoned Auto Commercial and is used for a motel. The property to the south across Port Avenue is zoned Harbor Commercial and is used for an auto parts store. The adjacent property to the east is zoned Auto Commercial and is used for telecommunication equipment and is part of the Alaska Railroad right-of-way. A paved pedestrian pathway along the property boundaries parallels Port Avenue to the south and the Seward Highway to the west and north. Floodplain status: According to the Kenai Peninsula Floodplain Map, the property is not located within a FEMA-mapped floodplain. Utilities: City water, sewer, and electricity are connected to the property. Parking: A drive-thru window does not require a specific number of parking spaces. The retail store is compliant with Seward City Code for the parking requirement. Comprehensive and Strategic Plan Consistency Information This legislation is consistent with (citation listed): Comprehensive Vol 1, Chapter 3.1.1.4 — "Support private sector business, employment, and Plan: programs." • Support and encourage the growth of business. Strategic Plan: N/A 51 Staff Comments Department Comments No Comment N/A Building Department X Fire Department X Public Works Department X Harbor Department X Police Department Making the exit, right turn only would be the safest route in order to prevent people from turning left across a merge lane, a regular north bound lane, a south bound turn lane and then into the regular southbound lane of travel. Additionally, we have a hotel across 3rd Ave from the Tufted Puffin which will have traffic trying to enter the roadway as well on what is the busiest roadway in Seward. Electric Department X Public Notice Property owners within three hundred (300) feet of the location of the proposed Conditional Use Permit action were notified of this public hearing. Public notice signs were posted on the property and all other public hearing requirements of Seward City Code § 15.01.040 were complied with. At the time of this publication the Community Development Department has not received public inquiries regarding the proposed Conditional Use Permit. If any correspondence is received after publication of this agenda statement, it will be submitted to the Planning and Zoning Commissioners for their review. 1. The applicant shall work with the building official through the building permit process to address any requirements per International Fire Code and International Building Code. 2. Signage shall be placed on the property indicating that the exit from the property onto the Seward Highway is a right turn only. 3. Signage shall be placed on the property indicating one-way traffic on the driveway going to and leaving the drive-thru window. 4. Per Seward City Code § 15.10.325(f). an approved CUP shall lapse six months from the date of approval if the use for which the permit was issued has not been implemented or a building permit obtained. The Commission may grant a six-month extension upon finding that circumstances have not changed sufficiently since the date of initial permit approval. 5. Modification of final approval of a conditional use permit may, upon application by the permittee, be modified by the Planning and Zoning Commission: 52 a. When changed conditions cause the conditional use to no longer conform to the standards for its approval. b. To implement a different development plan conforming to the standards for its approval. c. The modification plan shall be subject to a public hearing and a filing fee set by City Council Resolution. 1 Recommendation The proposed use is permittable through the Conditional Use Permit process, which allows the Commission the opportunity to ensure that the use is consistent with the purpose of the zoning district and surrounding land uses, is in harmony with the Comprehensive Plan, and will not be harmful to the public safety, health, or welfare. 53 Sponsored by: Applicant Public Hearing: February 4, 2025 CITY OF SEWARD, ALASKA PLANNING AND ZONING COMMISSION RESOLUTION 2025-006 A RESOLUTION OF THE PLANNING AND ZONING COMMISSION OF THE CITY OF SEWARD, ALASKA, GRANTING A CONDITIONAL USE PERMIT TO THE TUFTED PUFFIN LLC TO OPERATE A DRIVE-THRU WINDOW TO SELL RETAIL CANNABIS PRODUCTS AND NON - CANNABIS FOOD AND BEVERAGE ITEMS ON LOT 1, BLOCK 2, NORTH HARBOR SUBDIVISION; LOCATED AT 408 PORT AVENUE; WITHIN AN AUTO COMMERCIAL (AC) ZONING DISTRICT WHEREAS, The Tufted Puffin LLC has applied for a Conditional Use Permit (CUP) from the Seward Planning and Zoning Commission to operate a drive-thru window at their retail store located at 408 Port Avenue to sell retail cannabis products and other non -cannabis food and beverage items; and WHEREAS, the property is in an Auto Commercial (AC) zoning district; and WHEREAS, a marijuana retail store is allowed outright in the AC zoning district and is currently in operation on the property; and WHEREAS, a drive-in facility is defined as "any portion of a building or structure which by design permits customers to receive services, obtain goods or be entertained while remaining in their motor vehicles"; and WHEREAS, a drive-in facility requires a CUP in the AC zoning district; and WHEREAS, individuals with mobility issues such as the elderly or those with disabilities would be able to purchase marijuana products from their vehicles; and WHEREAS, the site plan shows that traffic will access the drive-thru window by entering the property from Port Avenue and exiting on the Seward Highway; and WHEREAS, the portion of Seward Highway directly in front of The Tufted Puffin contains highly trafficked north and southbound lanes as well as a center merge lane for traffic turning east onto Port Avenue; and WHEREAS, Port Avenue directly south of The Tufted Puffin is used by heavy industrial vehicles, other commercial vehicles, and non-commercial traffic turning south and merging north into the Seward Highway; and WHEREAS, a paved pedestrian/bicycle pathway along the property boundaries parallels Port Avenue to the south and the Seward Highway to the west and north; and 54 CITY OF SEWARD, ALASKA RESOLUTION 2025-006 WHEREAS, only one-way traffic will be allowed on the east side of the building where the drive-thru window will be operated; and WHEREAS, a drive-thru window has been operated from this building in the past when it was a fast food restaurant; and WHEREAS, the applicant is aware they will be required to comply with specific regulations set forth by the Alaska Alcohol and Marijuana Control Office (AMCO) for operating a drive-thru window to sell retail marijuana products; and WHEREAS, the property to the west across the Seward Highway is zoned Auto Commercial and is used for a motel; and WHEREAS, the property to the south across Port Avenue is zoned Harbor Commercial and is used for an auto parts store; and WHEREAS, the adjacent property to the east is zoned Auto Commercial and is used for telecommunication equipment and is part of the Alaska Railroad right-of-way; and WHEREAS, Seward City Code § 15.10.3200 recognizes that there are some uses which may be compatible with designated principal uses in specific zoning districts provided certain conditions are met; and WHEREAS, the applicant has complied with all of the public hearing requirements of Seward City Code § 15.01.040. NOW, THEREFORE, BE IT RESOLVED by the Seward Planning and Zoning Commission, that: Section 1. The Commission finds that the proposed use satisfies the following conditions as specified in SCC §15.10.320.D. A. The use is consistent with the purpose of this chapter (the Seward Zoning Code) and the purposes of the zoning district. B. The value of adjoining property will not be significantly impaired. C. The proposed use is in harmony with the Seward Comprehensive Plan. D. Public services and facilities are adequate to serve the proposed use. E. The proposed use will not be harmful to the public safety, health or welfare. Section 2. Any and all specific conditions deemed necessary by the Commission to fulfill the above -mentioned conditions shall be met by the applicant. Approval of the CUP shall be subject to the following conditions: 55 CITY OF SEWARD, ALASKA RESOLUTION 2025-006 1. The applicant shall work with the building official through the building permit process to address any requirements per the International Fire Code and International Building Code. 2. Signage shall be placed on the property indicating that the exit from the property onto the Seward Highway is a right turn only. 3. Signage shall be placed on the property indicating one-way traffic on the driveway going to and leaving the drive-thru window. 4. Per Seward City Code §15.10.325(f). an approved CUP shall lapse six months from the date of approval if the use for which the permit was issued has not been implemented or a building permit obtained. The Commission may grant a six-month extension upon finding that circumstances have not changed sufficiently since the date of initial permit approval. 5. Modification of final approval of a conditional use permit may, upon application by the permittee, be modified by the Planning and Zoning Commission: a. When changed conditions cause the conditional use to no longer conform to the standards for its approval. b. To implement a different development plan conforming to the standards for its approval. c. The modification plan shall be subject to a public hearing and a filing fee set by City Council Resolution. Section 3. The Planning and Zoning Commission finds that the proposed use, subject to the above conditions satisfies the criteria for granting a conditional use permit provided the conditions listed in Section 2 are met by the applicant before the drive-thru window is in operation, and authorizes administration to issue a conditional use permit to The Tufted Puffin LLC to operate a drive-thru window at their retail store located at 408 Port Ave to sell retail cannabis products and other non -cannabis food and beverage items. Section 4. The Planning and Zoning Commission finds that adherence to the conditions of this permit is paramount in maintaining the intent of Seward City Code Section § 15.10.320: Conditional Use Permits. A Conditional Use Permit may be transferred to a new owner per §15.10.320(G), in which case the new owner will be required to maintain conformance to the conditions of the permit. Section 5. Administration shall periodically confirm the approved conditional use conforms to the standards of its approval. Nonconformance to these above stated conditions shall be grounds for revoking the Conditional Use Permit. Section 6. This resolution shall take effect 10 days following its adoption. PASSED AND APPROVED by the Seward Planning and Zoning Commission this 4th day of February, 2025. 56 CITY OF SEWARD, ALASKA RESOLUTION 2025-006 AYES: NOES: ABSENT: ABSTAIN: ATTEST: Kris Peck City Clerk (City Seal) THE CITY OF SEWARD, ALASKA Carol Griswold, Chair 57 Context Map Single-family Residential Two-family Residential Multi -family Residential Auto Commercial Harbor Commercial Industrial Resource Management Park i I 200 feet Conditional Use Permit Application Property Map RES 2025-006 - Granting a conditional use permit to operate a drive-thru window to sell retail cannabis products and non -cannabis food and beverage items Location: 408 Port Ave Parcel #: 14510405 58 CITY OF SEVVARD P. 0. 13ox 167 410 Adams Sired Seward, Alaska 99664 Community Development 907.224.4048-1}irect.or 907.224,4020- Planner 907.224.4049- Planning Assistant CONDITIONAL USE PERMIT APPLICATION This completed application is to be submitted to the Community Development Department no later than four (4) weeks in advance of the next regularly scheduled Planning and Zoning Commission meeting. Regular meetings are held the first Tuesday of each month. The application must be accompanied by the $350 nonrefundable filing fee. In addition, please provide an as -built survey if the property has been developed or a scaled site plan with elevations if the property is undeveloped. Applicant: The Tufted Puffin Address: 408 Port Ave. Seward, AK 99664 Telephone Number: (907) 513-2393 Email: randy@thetuftedpuffin.com Property Owner (if other than applicant): TWO Black Dogs Property MGMT, LLC Address: 216 Fourth Ave Unit#4 Seward, AK 99664 Telephone Number: (907) 801-1162 Email: twoblackdogspropertymanagement@gmaii.com Property Description Address: 408 Port Ave. Seward, AK 99664 Lot Size: 0.46 Lot: L1 Block: B2 Subdivision: North Harbor Kenai Peninsula Borough Tax Parcel ID Number: 14510405 Development Information What structures are on the property? 1405 sq building How is the property being used? retail What is the proposed use of the property? retail What is the development timeline? already built Please note that prior to the Seward Planning and Zoning Commission granting a Conditional Use Permit, it shall be established that the proposed use satisfies the following conditions of Seward City Code 15.10.320 (See the attached pages for specific City Code requirements) 59 A) The proposed use is consistent with the requirements of the Seward Zoning Code and the designated zoning district. Please describe the use. Auto Commercial (AC) Our retail store is adding coffee service, and would like to re -open the once exciting drive -through. B) Describe any impacts to the adjoining properties and how property values may be affected. There is no impact to surrounding properties. This location has operated a drive through in years past when it was used for a restaurant. C) How is the proposed use consistent with the Seward Comprehensive Plan? Explain. You can view the plan at: http:I/www.cityofseward.usl We have attached a detailed explanation with this application D) Describe / list the public services and facilities that will serve the proposed use. (i.e., roads, utilities.) We have attached a detailed explanation with this application, including a traffic flow diagram E) The proposed project or use must not be harmful to the public health, safety and welfare. Describe any mitigation measures that may be needed to protect the public health, safety and welfare. We have provided detailed attachments with this application. F) Include building elevation plans and a site existing plan, drawn to scale. The site plan should include: 1) Property dimensions ✓ 2) Location and dimensions of and planned buildings 7 I 3) Parking configuration LI 4) Driveways and access ✓ 5) Natural features I v l 6) Other pertinent information I 60 I hereby certify that the above statements and other information submitted are true and accurate to the best of my knowledge and that I have the following legal interest in the property: Owner of record I understand that this item will be scheduled for action only if all application materials are submitted not less than three weeks in advance of the next regularly scheduled Planning and Zoning Commission meeting. Regular meetings are held the first Tuesday of every month. Applicant Signature: Property Owner Signature: Enclosed: $350 Payment V 224-Atio44,74. ct)ead. Dimensioned plot plan 1 drawings] Other: 61 REQUEST FOR CUP The Tufted Puffin randy@thetuftedpuffin.com 62 THE TUr QED PUFFIN On October 23, 2024, The Tufted Puffin team attended the Seward Planning and Zoning work session regarding current and proposed changes to Seward City code concerning marijuana use, retail sales, manufacturing, and cultivation. This was not the first work session on this topic, nor was it the first instance where our company faced scrutiny from both citizens and Planning & Zoning (P&Z) commissioners. We were deeply concerned by the prevalence of misinformation presented during both citizen comments and statements from some P&Z board members. Despite The Tufted Puffin's impeccable reputation within the City of Seward and the State of Alaska, our company was unfairly targeted by certain members of the public, the majority of which are not residents of the City of Seward, along with some P&Z commissioners. We chose not to engage during the public comment period or at any other time during the three-hour meeting, as it became evident that the session had devolved into what appeared to be a "Tufted Puffin Witch Hunt." We believed that any factual data we could have provided would not have been objectively considered or heard in that environment. Prior to the scheduled meeting, our company submitted multiple fact -based articles and financial data to the P&Z board. However, the board neither commented nor utilized any of the information we provided to correct the misinformation presented by both the public and at least one P&Z commissioner. This lack of acknowledgment further reinforced our concerns about the objectivity of the process and the board's willingness to consider all relevant information. Given the apparent bias demonstrated by the Seward P&Z board, The Tufted Puffin does not anticipate a fair review of our CUP application submitted on October 28, 2024. Therefore, we are formally notifying the Seward City Council, the Seward P&Z board, and the City of Seward Administration of our intent to appeal in the event that the P&Z board denies our CUP application. We believe this preemptive step is necessary to ensure our application receives the fair and unbiased consideration it deserves under local regulations and state law. We respectfully request that all parties involved consider the facts and merits of our application objectively, ensuring a fair and unbiased decision -making process. The Tufted Puffin has operated since February 2019 with an unblemished record, maintaining zero violations and consistently collaborating with the Seward Police Department and industry compliance regulators. Our track record speaks to our commitment to responsible business practices and community safety. Our dedication to positive community impact remains unwavering. We hope that, in time, we will demonstrate to the community, the P&Z commissioners, and the Seward City Council that The Tufted Puffin has been, is, and will always be a company that the City of Seward can be proud of. We are committed to fostering a relationship built on trust, transparency, and mutual respect with all stakeholders in our community. As we move forward, we invite open dialogue and collaboration to address any concerns and to showcase the positive contributions we continue to make to Seward's economic and social fabric. The Tufted Puffin 63 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com The Tufted Puffin 408 Port Ave. Seward, AK www.thetuftedpuffin.com To: City of Seward Planning & Zoning Seward City Council City Administration Regarding: CUP for The Tufted Puffin located at 408 Port Ave. Seward, AK 99664 Date: 10/28/2024 The Tufted Puffin, situated at 408 Port Ave. Seward, AK 99664, has fully embraced and aligned with the City of Seward's 2020 Comprehensive Plan. This living document, while evolving over time, has maintained its core values. Our company, both as a whole and at our Port Ave. location, has consistently supported and adhered to key aspects of the Seward Comprehensive Plan, particularly in the following areas: • Land Use and Development • Public Safety • Community Appearance • Economic Development • Port and Harbor Development • Tourism Promotion • Historic Preservation We have actively contributed to Seward's community values, including: • Maintaining the small-town feel and friendly atmosphere • Preserving the natural environment and open spaces • Enhancing community appearance through beautification efforts • Fostering community partnerships • Supporting public safety initiatives • Promoting responsible land development • Strengthening the local economic base THE TUFTED PUFFIN 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com 64 The Tufted Puffin is currently seeking a Conditional Use Permit (CUP) from the City of Seward to operate a drive -through at our Port Ave. location. This site has a history of drive -through service, previously housing a hamburger restaurant. After the property fell into disrepair, becoming an eyesore at the entrance to Seward, we purchased it in 2022 and began an extensive renovation process. Since acquisition, we have undertaken significant improvements: • Complete building remodel, including removal of dry rot • Installation of new plumbing and electrical systems • Successful completion of final building and fire inspections in spring 2023 • Extensive exterior property cleanup throughout 2023 and 2024 • Plans for professional landscaping in spring 2025 These efforts have not only brought the building up to code for the first time in years but also significantly enhanced the property's appearance, aligning with Seward's goals for community beautification and orderly development. By granting the CUP for our drive -through operation, the City of Seward would be supporting several key objectives outlined in the Comprehensive Plan: • Promoting infill development and utilizing vacant sites in established areas • Supporting private sector business growth and employment • Enhancing the attractiveness of the highway corridor • Contributing to year-round economic activity • Maintaining Seward's small-town character while facilitating growth The Tufted Puffin is committed to continuing our efforts to beautify the property and contribute positively to Seward's community appearance and economic vitality. We believe that our drive -through operation will provide a valuable service to both residents and visitors, supporting Seward's goals for sustainable economic growth while preserving its unique charm and character. TUI?TI;D PII1TIN 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com 65 The Tufted Puffin's retail location, situated at 408 Port Ave., received approval from the Kenai Peninsula Borough and the Alaska Marijuana Control Office (AMCO) in January 2023. We strategically delayed the finalization of our drive -through operations until after the busy summer season to ensure smooth implementation. Our innovative drive - through will operate exclusively during the months of October through March each year, catering to the unique needs of our community during the colder months. Customers aged 21 and over will have the opportunity to purchase both retail cannabis products and non -cannabis items such as artisanal coffee, espresso, and a curated selection of light, non-THC snacks. Our combined coffee and cannabis drive -through service brings numerous benefits to the Seward community, enhancing both convenience and economic vitality: 1. Job Creation: The drive -through operation requires additional staff to manage the increased volume of customers, creating valuable employment opportunities for local residents. These positions include skilled baristas, knowledgeable budtenders, cashiers, and management roles, contributing to a reduction in local unemployment rates and fostering professional growth within our community. 2. Unparalleled Convenience: We provide a quick and efficient option for busy individuals, such as parents, commuters, and workers, to obtain their coffee or cannabis products without the need to park and enter a store. This time -saving service significantly improves the daily routines of community members, especially during peak hours and inclement weather conditions typical of Alaskan winters. 3. Economic Boost: By attracting more customers and increasing local spending, our unique drive -through concept stimulates the local economy. This influx of business has a ripple effect, potentially leading to increased foot traffic and sales for nearby shops and services, fostering a thriving local business ecosystem. Additionally, our commitment to sourcing products from Alaskan growers and suppliers further strengthens the state's cannabis and coffee industries. 4. Community Engagement: The Tufted Puffin leverages its services to actively engage with the Seward community. We offer promotions tied to local events, support community initiatives, and partner with local suppliers for our products. Our drive -through serves as an informal community hub, facilitating brief social interactions and creating a sense of familiarity among regular customers. These efforts help strengthen community bonds and foster a sense of local pride. 5. Environmental Stewardship: As a progressive business, we implement eco-friendly practices to minimize our environmental impact. These include using biodegradable packaging, offering incentives for customers who bring reusable cups, & implementing energy -efficient equipment. 66 TII T D purr N 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com In addition to the general benefits of our drive -through service, our cannabis offerings provide several unique advantages to the local community: 1. Enhanced Accessibility: Our cannabis drive -through provides a discreet and easy way for customers to purchase products without leaving their vehicles. This is particularly beneficial for those with mobility issues, tight schedules, or those seeking privacy, ensuring that all members of our community can access our products comfortably and safely. 2. Safety and Regulation: By providing a safe, regulated environment for transactions, our drive -through service helps reduce the risks associated with black market purchases. All our cannabis products are rigorously tested and meet stringent safety standards, promoting responsible consumption within our community. Our knowledgeable staff is trained to provide guidance on product selection and usage, further ensuring customer safety. 3. Accessibility for Medical Users: For medical cannabis users who may have difficulty traveling, especially during harsh winter months, our drive -through offers a more accessible option to obtain their medication. This can be crucial for patients with chronic conditions or disabilities, ensuring they have consistent access to their prescribed products year-round. 4. Community Education and Outreach: As a responsible cannabis business, we are committed to community outreach through educational programs, health and wellness initiatives, and partnerships with local organizations. These efforts promote responsible use of cannabis products and help destigmatize cannabis use within our community. We regularly host informational sessions and workshops to educate our customers on the latest research and best practices in cannabis consumption. The Tufted Puffin's combined coffee and cannabis drive -through service enhances convenience, safety, and economic vitality in our local community while fostering a sense of connection and support. By contributing to the local tax base, we help fund community improvements and essential services, further solidifying our role as a responsible corporate citizen. Our commitment to maintaining a balance between providing accessible cannabis and coffee products while promoting responsible use and community well-being sets us apart in the industry. Through our innovative approach, The Tufted Puffin not only meets the diverse needs of our customers but also plays a vital role in the growth and development of Seward. We continually strive to adapt our services to the evolving needs of our community, ensuring that we remain a valued and integral part of Seward's unique cultural and economic landscape. STEW TUI?TI;D PIIfflN 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com 67 The Tufted Puffin, located at 408 Port Ave, Seward, AK, will offer a convenient drive - through service in compliance with Alaska Administrative Code 3 AAC 306.380. Our retail location will maintain exclusive control over the area immediately outside our walk- up or drive -through exterior window, ensuring it does not encroach on public property such as streets, sidewalks, or parking lots. Customers can place orders through various channels: • Internet or telephone (to be paid for and picked up in person) • At the walk-up window • Via the drive -through exterior window To maintain compliance and ensure customer safety, our staff will: 1. Physically view and inspect each customer's photographic identification 2. Verify that all vehicle occupants are 21 years of age or older, with exceptions for the customer's own children, grandchildren, or wards under 7 years old 3. Conduct all sales within the licensed premises To ensure security and regulatory compliance, our walk-up and drive -through areas are strategically positioned to minimize vulnerabilities. Every transaction is recorded by our video surveillance system, capturing the ID verification process and the completion of each sale. All video records are stored in accordance with 3 AAC 306.720. At The Tufted Puffin, we prioritize customer convenience without compromising on legal compliance or product quality. Our drive -through service offers a discreet, efficient way for customers to access our products while adhering to all state regulations. i\) � THE TUF°I`ED PUFFIN 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com To support our application, we have provided detailed drawings outlining the drive - through location and operation, along with a traffic flow diagram. We have worked diligently with the Kenai Peninsula Borough, which has approved our drive -through plan, demonstrating our commitment to compliance with local regulations and community standards. Moreover, by issuing a CUP to The Tufted Puffin for a drive -through operation, the City of Seward will be acting in accordance with its Comprehensive Plan. This decision would support private sector growth, and promote commercial development while preserving Seward's historic, small-town character. Our project represents a perfect balance between economic progress and community preservation, aligning seamlessly with Seward's vision for the future. TUl?T1;D PUffIN 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com SEWARD HIGHWAY s saa BEessaa O.0 1 adoa d Y 17 diT:JOd TSV1 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com 70 408 Port Ave. Seward AK As Built Survey poousigt Bersdnuot 71022SCAsSFS2.4.11 6-BESA-CEBEA41I MU 12/3612022 1 2t32 PH re"3 NOTES; 1) DUE TO SNOW & ICE COVER, SOME SURFACE LEVEL FEATURES ARE APPROIONIATE, 2) A PORTION Of DIE LOT WAS TAKEN or aXDOT&Pf FOR R.O.W. Mae. NO. 2004-001171-0) / - Lot 1. 1S,4SS S_F. PORT AVENUE MEL if/ TKJ 101: -1 EIJORY COMMERCIAL BUILDING MI PINSK: 1TINIErt / WORM= SURVEY „.E.,„, SCALE GRID .4"- ii�b1 Avenue Amhara**. Alaska 119614-41140 Lang & Associates, Inc. pon &22-6474% phone On•lendeurVeroben1 Professional Land Surveyors JonalharrOlarlopurvey,,earn travlselientisurser,COM 5.4r..4 NIL Seward Reoofdtits District, Alaska. and that lblIe Wrliage LOcO11041 Survey REWAINOER of LOT 1, BLOCK 2, NORTH NARDOR SUBDIVISION MAT I. DO or*: 49Th I hunts* sorely that 1 tunes surveyed the loiiowing SPEOV115911 Pre_Pertin so osonbetion cd the oondrsione Inet were found on She dole the survey yeas essformod. TM* survey does not constitute a boundary surrey and Is tublatil la any Irleeektraelos net be used to ostablION any fenCer Minteltir Ile Or other renPraYMMOIVII. , -a.. kEntETSI O. VHS that a subsequent boundary survey Mai drechiee. The Informallan contained hereon hel . 1...y1,1-- , al Anchorage. Altil,-.0 — ''''e. „ 'ir,(4s;' 41.tittrSal •',.., paw mi. til• '_'_LL_" pay 4,1 _2-.. -,-.T.,",-. ,- gliCirkSiDIF60, -‘7,41400,z,og'.. 0 tir it. reeponeibility of the Owner ha determine the eubstenCs of ons easements, oceranands. es reettiellasur which do not appear an the rearded embah101en plot. Slate of Alaska AE00063 TUFTED Purim QICS2EATION,‘L DISPFIASARY 10/28/2024 The Tufted Puffin www.thetuftedpuffin.com Alaska Alcohol and Marijuana Control Office (AMCO) Regulations 3 AAC 306.380. Walk-up or drive -through exterior window pick-up for retail marijuana stores (a) Unless prohibited by local law, a licensed retail marijuana store may serve a consumer through a walk-up or drive -through exterior window in compliance with the requirements of this section. (b) Before accepting orders for sales of marijuana or marijuana products through a walk-up or drive -through exterior window, a licensed retail marijuana store shall submit an operating plan or modification of an operating plan of the licensed premises to the board for approval. The operating plan or modified operating plan must depict the walk-up or drive -through exterior window area and the video surveillance of the walk-up or drive -through exterior window area. (c) The area immediately outside a walk-up or drive -through exterior window must be under the licensee's sole possession and control and may not include any public property including public streets, public sidewalks, or public parking lots. (d) The licensed retail marijuana store may accept Internet or telephone orders or may accept orders from the consumer at the walk-up or drive -through exterior window. Internet or telephone orders must be paid for and picked up in person by the consumer placing the order. All orders received through the walk-up or drive -through exterior window must be placed by the consumer from a menu. The retail marijuana store may not display marijuana or marijuana products at the walk-up or drive -through exterior window. (e) Before completing a sale at a walk-up or drive -through exterior window, the licensee or the employee shall physically view and inspect the consumer's photographic identification. Each person in a vehicle at the drive -through exterior window must be 21 years of age or older, unless the person is the consumer's own child, grandchild, or ward who is not older than seven years of age seated or otherwise required by local or state law to be seated in a car seat or booster seat. (f) All sales must occur within the licensed premises. This requirement is satisfied if payment is made through the following means: (1) by an electronic Internet -based payment platform; (2) by a mobile payment point -of -sale system; (3) by payment transferred through the walk-up or drive -through exterior window into the interior of the retail marijuana store. (g) A walk-up or drive -through exterior window area (1) must be located (A) so that compromises to security are minimized; 72 (B) so that for each transfer of marijuana or marijuana product through the walk-up or drive -through exterior window, the licensed retail marijuana store's video surveillance records (i) the licensee's or employee of the licensee's verification of the consumer's photographic identification; and (ii) the complete transaction; and (C) within the licensed premises of the retail marijuana store; (2) may not be (A) in a building separate from the licensed premises of the retail marijuana store; (B) in a movable structure, including a trailer or separate drive -through structure; or (C) accessible only through a licensed premises of a different license type or the overlapping premises with another license type. (h) The licensee shall ensure that sales and all interactions at the walk-up or drive -through exterior window are video recorded and the records are stored in compliance with 3 AAC 306.720. (i) Sales of marijuana or marijuana products via a walk-up or drive -through exterior window are subject to requirements and restrictions imposed by the relevant local government. (Eff. 8/13/2023, Register 247; am 12/8/2024, Register 252) 73 CITY OF SEWARD, ALASKA AFFIDAVIT OF MAILING PUBLIC HEARING NOTICE (!L&tc 12)rovrr, , upon oath, deposes and states: That she is employed in the Community Development Office of the City of Seward, Alaska; and that on j anUniLi i co, ? 02S she mailed a Notice of Public Hearing to the real property owners within a 300-foot periphery of North Harbor Subdivision, Lot 1, Block 2; Located at 408 Port Avenue as prescribed by Seward City Code 15.01.040/16.01.015. 1 .1,h Affirmed and signed this I —day of 2025. AFFIDAVIT OF POSTING PUBLIC HEARING NOTICE 1, 12fAnD)t . Ltd , hereby certify that I have posted a Notice of Public Hearing, as prescribed by Seward City Code 15.01.040/16.01.015 on the property located at North Harbor Subdivision, Lot 1, Block 2; Located at 408 Port Avenue on which the applicant has petitioned for a Public Hearing for a Conditional Use Permit to construct and operate a drive-thru window to sell cannabis products and food and beverage items, within an Auto Commercial (AC) Zoning District. The notice was posted on 1 1 Lr 1 Z 5— , which is 1L days prior to the public hearing on this petition. I acknowledge this Notice must be posted in plain sight, maintained and displayed until all public hearings have been completed. Affirmed and signed this t day of , 2025. 75 Planning and Zoning Agenda Statement Meeting Date: February 4, 2025 To: Planning and Zoning Commission Through: Daniel Meuninck, Community Development Director From: Courtney Bringhurst, Planner Agenda Item: Resolution 2025-007, of the Planning and Zoning Commission of the City of Seward, Alaska, Recommending City Council Approval of the Planning and Zoning Commission Priorities for January 2025 to January 2026 Background and justification: Under the direction of the City Council, the Planning and Zoning Commission establishes priorities annually. During their January 21 st work session, the Commission discussed which topics should be their priorities for 2025. The attached Resolution contains the updated priorities meant to guide the Planning and Zoning Commission during the year 2025. Intent: To establish the 2025 Planning and Zoning priorities and recommend the City Council's approval of those priorities. Comprehensive and Strategic Plan Consistency Information This legislation is consistent with (citation listed): Comprehensive The priorities of the Commission are based on the goals and objectives Plan: established in the Comprehensive Plan. Strategic Plan: N/A Recommendation Community Development Department staff recommend approval of Resolution 2025-007 approving the Planning and Zoning Commission Priorities for January 2025 to January 2026. 76 Sponsored by: Staff CITY OF SEWARD, ALASKA PLANNING AND ZONING COMMISSION RESOLUTION 2025-007 A RESOLUTION OF THE PLANNING AND ZONING COMMISSION OF THE CITY OF SEWARD, ALASKA, RECOMMENDING CITY COUNCIL APPROVAL OF THE PLANNING AND ZONING COMMISSION PRIORITIES FOR JANUARY 2024 TO JANUARY 2025 WHEREAS, the Seward City Code §2.30.225(B) states that "the Commission shall act in an advisory capacity to the City Council regarding the Seward Zoning Code, Seward Comprehensive Plan, Official Zoning Map, Official Land Use Plan Map, and other duties as requested by the City Council"; and WHEREAS, the Planning and Zoning Commission discussed their priorities during the January 21 st work session; and WHEREAS, City Council will address a resolution adopting these recommendations. NOW, THEREFORE, BE IT RESOLVED by the Seward Planning and Zoning Commission, that: Section 1. The following list of priorities are hereby recommended to the City Council for approval: SHORT TERM (2025) SPECIFIC PRIORITIES • Through the powers of the Commission, contribute and collaborate as needed to help be part of the solution for the housing issues that Seward is facing including recommending changes to the Muni Land Plan and Title 15. o Current discussions to be continued throughout 2025 are building height regulations and accessory dwelling units. • Comprehensive Plan Update: Continue to promote public engagement in the Comprehensive Plan update process and provide assistance as requested. • Complete update of Planning and Zoning Rules and Procedures document. • Review parking requirements in City Code. • Revise requirements and improve compliance and enforcement for Conditional Use Permits: Create a higher standard for applications and approved developments and improve compliance. 77 CITY OF SEWARD, ALASKA RESOLUTION 2025-007 • Revise and update Sign Code: Using Anchorage's 2024 sign code update as a guide, revise Title 15.20 Signs to bring it into compliance with the Supreme Court's ruling in the Reed v Town of Gilbert case from 2015. • Review and update the Municipal Lands Inventory and Management Plan (MLIMP) for 2025. Preferably conduct two reviews, one in the spring and one in the fall before final approval. ONGOING PRIORITIES • Review and make recommendations to update Title 15 and Title 16 as needed. • Review and update the Municipal Lands Inventory and Management Plan (MLIMP) to meet the current and future needs of the City of Seward. • Review the Seward Marine Industrial Center (SMIC) development plan with the Harbor Master and Port and Commerce Advisory Board. Collaborate on how to integrate updated maps from the MLIMP and a future zoning overlay into the plan. • Work with the Seward Bear Creek Flood Service Area Board on any projects or plans that pertain to flooding issues within the City of Seward. • Planning & Zoning Commissioner education and training (Conduct mini training sessions during work sessions throughout the year. Attend any trainings provided by the Alaska Chapter of the American Planning Association) Section 2. This resolution shall take effect immediately upon adoption. PASSED AND APPROVED by the Seward Planning and Zoning Commission this 4t' day of February, 2025. AYES: NOES: ABSENT: THE CITY OF SEWARD, ALASKA Carol Griswold, Chair 78 CITY OF SEWARD, ALASKA RESOLUTION 2025-007 ABSTAIN: ATTEST: Kris Peck City Clerk (City Seal) 79