HomeMy WebLinkAboutOrd1975-406A r ATTACHED TO AND MADE A PART OF THE MINUTES OF THE SEWARD CITY COUNCIL-VOLUME 16 PAGE 95 THE CITY OF SEWARD, ALASKA James R. Filip, City Clerk-Treasurer ORDINANCE NO. 406 A AN ORDINANCE PROVIDING MINIMUM STANDARDS FOR CONSTRUCTION OF WATER AND SEWER LINES, AND AMENDING CHAPTER 22 OF THE CITY OF SEWARD CODE OF ORDINANCES. THE CITY OF SEWARD, ALASKA, ORDAINS: Section 1. is hereby amended to for water connection least once a year." Section 22-2 of the Seward Code of Ordinances delete the last sentence which reads "Charges shall be reviewed by the utility board at The remainder of Section 22-2 remains the same. Section 2. Section 22-9 of the Seward Code of Ordinances is hereby created to read as follows: Sec. 22-9 Meters Required. Water meters shall be provided for all commercial and industrial buildings and uses, and for all state and federal govern- ment buildings and uses. Water meters shall also be provided for residential buildings containing five (5) or more units. Single family residence, duplexes, triplexes, and fourplexes need not be metered. Section 3. Section 22-10 of the Seward Code of Ordinances is hereby created to read as follows: Sec. 22-10 Certain Minimum Standards. (a) All new building construction shall have water and sewer service lines that are buried a minimum of nine (9) feet be- low the surface of the ground, measured from the surface of the ground to the bottom of the pipe. If other conditions prohibit this burial, then the line must be encased in insulation of a type and thickness which must be approved by the city engineer. The city engineer may allow the depth of burial with proper insulation to be less than nine (9) feet, but under no circumstances may the depth of burial be allowed to be less than six (6) feet, with the exception that sewer connections requiring less than six (6) feet burial for connection to existing sewer mains and laterials shall have adequate insulation to assure protectio~. (b) All new water mains and sewer lines shall be buried a minimum of nine (9) feet below the surface of the ground, measured from the surface of the ground to the bottom of the pipe. If other conditions prohibit this burial, then the line must be encased in insulation of a type and thickness which must be approved by the city engineer. The city engineer may allow the depth of burial with proper insulation to be less than nine (9) feet, but under no circumstances may this depth of burial be allowed to be less than six (6) feet. (c) All major building remodeling, renovation, upgrading, or improvement that constitutes more than twenty-five percent (25%) of the borough assessed value of the structure must include water line reconstruction with the new line burial a minimum of nine (9) feet below the surface of the ground, measured from the surface of the ground to the bottom of the pipe. If other conditions prohibit this burial, then the line must be encased in insulation of a type and thickness which must be approved by the city engineer. The city engineer may allow the depth of burial with proper insula- tion to be less than nine (9) feet, but under no circumstances may this depth of burial be allowed to be less than six (6) feet. (d) No new connections of floor or roof drains to sanitary sewer lines shall be permitted, nor shall any interconnections be- tween storm and sanitary sewer lines be permitted. (3) Plans for all new water and sewer lines and connections must be approved by the city engineer, and the completed lines must be inspected by the city prior to burial. Section 4. This ordinance takes effect immediately upon passage and approval. PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF SEWARD, ALASKA, this 23 day of June, 1975. CITY OF SEWARD, ALASKA By ~J j.;t/~" Mayor FIRST READING: SECOND READING: ADOPTION: AYES: NOES: ABSENT: 6/9/75 6/16/75 ~ 6/23/75 Getman, McCloud, Hulm, Dague, Lutz and Neve'. NON E Oldow ATTEST: ~il4 ~ C e k Approved as to Form: THORSNESS, LOWE, GANTZ & POWELL for the City of Seward