HomeMy WebLinkAbout03122012 City Council Laydown .
MEMORANDUM CITY OF SEWARD
PO Box 167.SEWARD.ALASKA 99664
TO: Jim Hunt DATE: February 8,2012 LY1(2-42--
City Manager
/11
FROM: David Squires PROJECT: Engine 4 Replacement
Fire Chief
SUBJ: Request to Use Alternate Procurement Procedures—SCC 6.10.310
In accordance with Seward City Code 6.10.310(a) we are recommending the City utilize request for sealed
competitive proposals for the above referenced project. This procedure will best serve the needs of the City
and accomplish the objectives of Seward City Code Title 6 Purchasing,Contracts and Professional Services.
Using the RFP process allows vendors to have dialogue with us on our specifications, allows for
alternative methods to the specifications without changing the desired function and allows for substitutions
that may save money.
We will still follow the requirements for advertising,sealed proposals,evaluation criteria,award of contract
and bond posting for the RFP.Attached to this memorandum is the evaluation criteria that will be used for the
RFP and copies of all or the top three will be submitted to the Council for their approval of the award of
contract.
We are also asking for the latitude to consider the purchase of stock or demo unit that meets most or all of our
specifications.This may shorten the delivery time of the vehicle substantially and may be a better value to the
City.
•
Fire `__ :f David Squires . Date
Approved:
Jim Hunt, City Manager Date
Per Seward City Code 6.10.310(b) please include the above information in your next City Manager's Report to
Council.
S:\Shared Computer Files\PROJECT FOLDER\RFP AND BID DOCUMENTS\2012 Engine 4 Replacement\Memo to Mgr.re RFP Process for vehicle acquisition.doc
•
MEMORA\DUM City of Seward
Box 167, Seward AK
3�l ZIIZ Nr15
TO: Jim.Hunt Date: March 9, 2012
City Manager
FROM: Ron Long Project: Seasonal Transportation Services
Assistant City Manager
Community Development Director
. Subject: Request to use alternate procurement procedures—SSC 6.10.310
In accordance with Seward City Code 6.10.310 (a) it is recommended that the City utilize request
for sealed competitive proposals for the above referenced project. This procedure will best serve
the needs of the City and accomplish the objectives of Seward City Code Title 6 Purchasing,
Contract and Professional Services.
Using the RFP process allows the vendors to have a dialog with us on the requirements of the
contract and services provided.
The City will follow the requirements for advertising, sealed proposals, evaluation criteria, award of
contract and bond posting for the RFP.
•
Ron Long, Assistant City Manager Date
01)„,
Appioued:._...
�i Hunt, City •anager Da e
•
Per Seward City Code 36.10.310 (b) please include all the above information in the next City
Manager's report to Council.
•
� I
/iz/iz P'
SEWARD FIRE DEPARTMENT ENGINE 4 REPLACEMENT PUMPER 2012 2/1/2012
VENDOR NAME mandatory
ADDRESS would like
PHONE CONTACT EMAIL:
CONTACT NAME
ASPECT OF RFP I Possible Points
( INFO ON THIS RFP PROPOSAL Cost Awarded Points
PRICE
Options?
Notes
DEMO Vehicle
DOWN PAYMENTS none 10 pts
25% 5 pts
50% 1 pt
DELIVERY TIME 181-to 210 days 10 pts
211 to 240 days 9 pts
241 to 270 days 8 pts
271 to 300 days 7 pts
301 to 330 days 5 pts
330 to 364 days 2 pts
365 days ( 1 year) or more 1 pt
WARRANTY 1 Point for each Year of warranty
Engine
Chassis
Body
Drive Train
Pumps
Electrical Systems
Water Tanks
ASPECT OF RFP INFO ON THIS RFP PROPOSAL Awarded
Possible Points I Cost I Points
SPECIFICATIONS:
Length Maximum 408" ( 390" optimum) •
Height 115 "to 116"Maximum
(9 feet 7" to 9 feet 8")
MANUALS - ALL SHOP MANUALS ( ELECTRICAL, MECHANICAL, ETC)
Two Complete Sets V 5 pts
SPECS
Cab 5 pts Custom tilt style built for Fire Service
1 pt Other
•
Chassis 1 pt 400 + horse power diesel motor
1 pt 5 speed automatic transmission
*Other?
5 pts - Transmission retarder or Jake Brake
Chassis Data Labels 5 pts Fluid Data -
5 pts Chassis Data
5pts - Manufacturer's Weight Certification
5 pts Cab Safety Signs • V
Cab Roof 5 pts Flat Design
1 pt Raised Design
- 150 watt/12 volt HID brow light-center front-controls within reach
5 pts of driver&officer
1 p ** Other? - - -
Aluminum tread plate overlay
Drip rail-full length of cab-Aluminum
Cab Doors 1 pt 4 side opening doors - -
5 pts Openable, hand crank style, tinted windows
5 pts Flashing red light on scuff plate V
DO NOT MOVE APPARATUS WHILE LIGHT IS ON-light/buzzer if
5 pts doors are open
ASPECT OF RFP I INFO ON THIS RFP PROPOSAL Awarded
Possible Points Cost Points
Cab Seating - 5 pts Seating for 6 individuals/custom
3 pt Seating for 5/facing forward/commercial
5 pt ' H.O. Bostrom Sierra Torsion 380 - Driver seat
5 pt H.O.Bostrom Tanker 450 Ex6/ABTS-officer'seat
5pt H.O. Bostrom.Tanker 400 CT Flip-up/ABTS-crew
1 pt All Seats -Gray Tweed Durawear material
1 pt Other types/brand of seats
Water& Foam Tank 5 pts 1000 gallon water tank
1 pt ** Other?
1 pt Tank to pump piping 4"
1 pt Pump to tank(fill) 4"
5 pts - Top fill capable
5 pts - Tank overflow discharge behind rear wheels
5 pts 20 gallon foam tank
** Other
5 pts Foam Tank-controls on left pump panel
Body 5 pts Hose bed to carry 1000'of 5" hose.
5 pts Hose bed.to carry 1000' of 3" hose
5 pts Hose Bed- Black-vinyl
5 pts . Two (2) Crosslay compartments 200' of 1,3/4" hose
- 1 pt _ _ Driver side full height 36"x 62"front compartment w/rollup door
:1 pt . - Driver side 59"x 29 1/2" middle compartment w/roll up door
1 pt - Driver side 36"x 62" rear compartment w/roll up door
1 pt Officer side 36"x 62"front compartment w/roll up door
1 pt Officer side 59"x 29 1/2" middle compartment w/roll up door
1 pt Officer side full height 36"x 62" rear compartment w/roll up door
1 pt Three.(3)slide trays on compartments
**Other
1 pt Two (2) slide or swing panels on compartments
**Other
5 pts Ladder rack on RIGHT side
5 pts Ladder rack to hold 35' ladder
5 pts ' Ladder rack to hold 14' roof ladder
5 pts - Ladder rack to hold 2 pike poles (6'and 12')
** Through tank ladder storage considered
** Hydraulic ladder rack considered -
5 pts Two (2) 10 foot hard section hoses.
ASPECT OF RFP INFO ON THIS RFP PROPOSAL Awarded
Possible Points I Cost I Points
NO NOT MOVE APPARATUS WHILE LIGHT IS ON light on AND
Body Cont. 5 pts BUZZER when any compartment open
5 pts 1.0 KW hydraulic generator with start control on pump panel
1 pt ** Electrical outlets on each side& rear of vehicle
Two (2) 150 watt 12 volt HID scene lights mounted on rear one on
5 pts each side,switches in cab for driver.& officer reach
Folding steps at rear-on both sides for access to hose bed &
• 5 pts Handrails
Fire Pump& 5 pts Hale 1500 GPM single stage pump.
Discharges: ** Other?
1 pt Two (2) discharges on each side of vehicle- nst connections
1 pt Discharges with a 30 degree adaptor outlet
2 1/2" discharge with 30 degree adaptor in rear controlled at pump
1 pt panel
•
1 pt Two (2) 2 1/2 " intakes, one on each side
1 pt Two (2) 6" intakes, one on each side
5.pts Discharges to be color coded on pump panel -
5 pts Deck gun TFT Typhoon RC model Y5C-52
**Other?
1 pt Valved 5"storz intake on right rear of vehicle w/30 degree intake
5 pts Two (2) 1 1/2" discharges for the crosslays
5 pts - Intake relief valve system plumbed on suction side of pump
Excess plumbed to discharge under vehicle away from personnel
1 pt' (NFPA 1901)
5 pt Fully openable pump panel access doors (without tools)
Gauges 2 pts Waterproof gauges -
2 pts Back lighting
2 pts . 6"diameter master intake and pump discharge gauge
2 pts 3"diameter gauges for all discharges
2 pts Discharge gauges will show PSI and GPM
2 pts Gauges will be color coded for each discharge
2 pts - Gauges will be readily available/easy to reorder/replace
Fire Research In Control Model TGA200 pressure governor&
• 1 pt monitoring system
1 pt LED water and foam tank level gauges
ASPECT OF RFP INFO ON THIS RFP PROPOSAL Awarded
Possible Points Cost I Points
Misc Items " 5 pts - Drop down chains for rear wheels
5 pts Emergency lighting will be LED/placed per NFPA
1 pt, All directional &stop lights will be LED
1 pt All compartment&ground lighting will be LED
1 pt Compartment lights will have controls in the compartment
Ground lights will have control switch in cab by driver& officer
1 pt seating
1 pt Two(2)air horns shall be installed in the front bumper
Air horns will be actived by lanyard located inbetween driver and
1 pt officer positions
Electronic 200 watt siren with PA capabilities in cab within reach
1 pt of driver& officer positions
Siren will have 200 watt speaker located of center of front bumper
• 1 pt or grill area
• 1 pt Federal Signal Q2B siren -activated with a foot pedal
1 pt Windshield wipers -electric -2 speed and intermittent capabilities
1 pt Color RED
6 "wide WHITE reflective stripe placed to show length and height
1 pt of vehicle
Reflective lettering on the front of the cab-front doors- before the
rear doors- rear of vehicle referencing SFD. (similar to
1 pt existing)
1 pt Rear of vehicle shall have safety chevrons per NFPA standard
Installation of Motorola XTL2500 mobile radio.lnterconnect to
5 pts intercom system. -
Vehicle exhaust to be fitted with Plymovent connection to fit
5 pts existing ventilation system.
5 pts Kussmaul battery charger
1 pt Air Compressor
1 pt Auto eject plug
1 pt ALL plugs to be located on LEFT side of vehicle
1 pt Chrome wheel covers for each outside wheel
1 pt Two tow hooks on the front of the vehicle ( Secured to chassis)
1 pt Two tow eyelets on the rear of the vehicle ( Secured to chassis)
ASPECT OF RFP INFO ON THIS RFP PROPOSAL Awarded
Possible Points Cost Points
One set of driving lights & one set of fog lights mounted under
Options 2 pt front bumper with switch controls accessible to driver
Storage unit for pre-fire plans, hose charts,writing pad,
binoculars and reference books. Location on the unit in cab area
2 pt to:be determined.
2 pt HID scene lights on each side of vehicle
2 pt Pull out rear step to facilitate hose loading
Shipping Information
Comments and Notes
Brenda Ballou //2. 2,Q f
From: Dave Squires L_AV f o1 ► J/'
Sent: Monday, March 12, 2012 1:59 PM
To: Brenda Ballou
Cc: Janice Melvin
Subject: Liquor license renewal
Brenda,
Terry's Fish &Chips are now in compliance with our regulations.There is no objection from this office on the renewal.
David Squires
Fire Chief
•
•
1